Quantum 4500P / 5500P / 5500 P-16 / 5500 P-18 / 5500Gt / 6500P / 6800P; Prior To Operation - Claas QUANTUM 3500 Service Parts

Technical systems
Table of Contents

Advertisement

TIC
4.0 QUANTUM 4500P / 5500P / 5500 P-16 / 5500 P-18 / 5500GT /

4.0.1 Prior to operation

3 Hydraulic hoses
35 LS port (control line)
Important!
10/04
QUANTUM
6500P / 6800P
In this system, the setting of the tractor's pressure relief valve must be at
least 5 bar below the setting or pressure relief valve (8).
When the pressure relief valve (8) responds, the tractor pump starts
delivering. This may result in overheating of the hydraulic oil.
Clean the hose couplers of the hydraulic hoses (3) and the oil
outlets on the tractor before each hitching.
Connect the two hydraulic hoses (3) to a double-acting control unit
or a single-acting control unit with a free return line.
The pressurized line is identified by a red marking.
Never apply pressure to the return line (not marked).
Oil quantity from the tractor max. 60 l/min
Hydraulics
11-73