Changing the indication mode of "Alarm" is
made by closing the Ind contact for at least 10
sec.
- 1-time flash – indication enabled;
- 2-time flash – indication disabled.
6 INSTALLATION PLACE
1) Recommended installation height is 2.3+-0.05
m.
2) Install detector on bearing walls and carri-
ers.
3) Alarm loop and power supply wires should
be located far from power cables.
To eliminate false alarm hazards
1)
It is recommended to close all doors, air-
vents, switch off fans, air-conditioners and other
sources of intense air flows in the room during
protection
period.
2)
Any furniture or interior items within 3 m of
the detector which could make possible for an
animal to climb above the floor level must be
removed.
Not recommended installation locations
7 INSTALLATION PROCEDURE
1) Open the
detector by pushing
the cover latch out
of the groove in the
base
2) Fix the bracket
to location chosen
for installation
of the detector
3) Install the detector
on the bracket and
connect the wires (see
section 8).
Orient the detector
base
strictly
vertically according
to the drawing!
There is a possibility of installation using a ball
bracket (supplied separately).
4) Replace the detector
cover
(until it clicks).
5) Perform Test (see.
section 9).
6) Set the required indication
mode (see section 5).
8 WIRING
Perform wiring to detector`s terminals in
accordance
with
control
manual.
TMP – detector tampering control terminals;
Relay – terminals for detector connection to
alarm loop;
+12V, GND – power supply terminals.
9 TEST
1) Switch on the detector
power
supply.
The
indicator will flash for a
maximum of 60 seconds.
2)
To
detect
sensitive
zones carry out TEST-
pass
across protected
area with the speed of 0,3
and 3 m/sec .
Stop upon detection (indicator lights up for
2sec), mark position, then make a step back
and continue moving.
Repeat TEST
inversely.
The sensitivity zones formed by the lens will be
located in the middle between the marked
positions.
10 WARRANTY
The operation warranty period is 5 years from
the date of operation start-up but no longer than
5 years 6 months from the date of manufactur-
ing
subject to the requirements of User guide.