■ Interrupt condition target input output terminal setting range [n]
Set the target I/O terminal number so that if an interrupt factor is detected on the set terminal, an interrupt is performed.
• Input module with diagnostic functions
Item
Interrupt condition target input output
terminal setting range [n]
*1 n indicates the interrupt setting number. (n: 1 to 16)
*2 X00 to X0F are set as the interrupt condition target input terminals.
• Output module with diagnostic functions
Item
Interrupt condition target input output
terminal setting range [n]
*3 n indicates the interrupt setting number. (n: 1 to 16)
*4 Y00 to Y0F are set as the interrupt condition target output terminals.
■Interrupt pointer
Specify the number of an interrupt pointer which is started when an interrupt factor is detected. For details on the interrupt
pointers, refer to the following.
 MELSEC iQ-R CPU Module User's Manual (Application)
1 FUNCTIONS
40
1.3 Common Functions of the I/O Module with Diagnostic Functions
Setting range
X00
*1
X01
X02
X03
X04
X05
X06
X07
X08
X09
X0A
X0B
X0C
X0D
X0E
X0F
All input terminal designation
Setting range
Y00
*3
Y01
Y02
Y03
Y04
Y05
Y06
Y07
Y08
Y09
Y0A
Y0B
Y0C
Y0D
Y0E
Y0F
All output terminal designation
*2