Technical data

General

If the power source is designed for a special voltage, the technical data on the
rating plate applies. The mains plug, mains lead and their fuse protection must
be rated accordingly.

TP 4000 CEL

Mains voltage
Mains voltage tolerance
Mains fuse protection
Mains connection
Primary continuous
power
Cos phi
Welding current range
Welding current at
Standardised working voltage
Maximum working voltage
Open circuit voltage (pulsed)
Degree of protection
Mark of conformity
Type of cooling
Insulation class
Dimensions l x w x h
Weight
Power source efficiency at 380 A / 35.2 V
1)
2)

TP 4000 CEL MV

Mains voltage
Mains voltage tolerance
Mains fuse protection
108
1)
100% D.C.
10 min / 40°C
10 min / 40°C
10 min / 40 °C
Connected to public grids with 230 / 400 V and 50 Hz
D.C. = Duty cycle
Restrictions possible
2)
MMA
TIG
40% D.C.
60% D.C.
100% D.C.
MMA
TIG
MMA
Peak value
Average value
625 x 290 x 475 mm
24.6 x 11.4 x 18.7 in.
3 x 400 V
+/- 15%
35 A slow-blow
12.9 kVA
0.99
10 - 380 A
10 - 380 A
2)
380 A
360 A
2)
320 A
2)
20.4 - 35.2 V
14.5 - 33 V
53 V (380A)
80 V (10 A)
95 V
60 V
IP 23
S, CE
AF
F
36.1 kg
79.6 lbs
89 %
10 - 380 A
10 - 380 A
+/- 10%
200 - 240 V: 35 A
380 - 460 V: 35 A