Table of Contents Model RE-CN-0045-HC / Model RE-CN-0009-HC / Model RE-CN-0014-H Model RE-CN-0023-HC / Model RE-CN-0023-H / Model RE-CN-0052-HC Model FR-CN-0790-HC / Model FR-CN-1250-HC / Model FR-CN-0045-HC Section Page Disclaimer -------------------------------------------------------------------------------------------- 3 General Information --------------------------------------------------------------------------- 4 - 5 Safety and Warranty...
Disclaimer OMCAN IS NOT RESPONSIBLE FOR ANY DAMAGES DUE TO WATER LEAKS. WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75°F AND 55% RELATIVE HUMIDITY, AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRECTLY TO A FLOOR DRAIN.
If the package has suffered rough handling, bumps or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be filled out within three days, from the delivery date shown in the shipping documents.
Si el paquete ha sufrido un manejo de poco cuidado, golpes o daños (visible o oculto) por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas, de modo que podamos iniciar una reclamación con la compañia.
Page 6
2 YEARS PARTS AND LABOUR / 5 YEARS PARTS ONLY ON COMPRESSOR WARRANTY Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized service technician to repair the equipment locally. Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not improper use.
Technical Specifications GLASS DOOR COOLERS Model RE-CN-0045-HC RE-CN-0009-HC RE-CN-0014-H Temperature Range 0 - 5°C / 33 - 41°F Max Ambient Temp Rating 32°C / 90°F Power 1/4 HP 1/5 HP Electrical 110V / 60Hz / 1 115V / 60Hz / 1 Current 4.3A...
Page 8
Technical Specifications GLASS DOOR FREEZERS Model FR-CN-0012-HC FR-CN-0790-HC FR-CN-1250-HC Temperature Range -23 to -18°C / -10 to -0.4°F Max Ambient Temp Rating 32°C / 90°F Net Volume 368 L / 13 cu. ft. 648 L / 23 cu. ft. 821 L / 29 cu. ft. Power 3/4 HP Electrical...
Installation IMPORTANT!!!PLEASE READ BEFORE INSTALLATION • The refrigeration system operates most efficiently when installed in an area with cool, dry air circulation. • There must be at least 6 inches of clearance on both sides and the back of the cabinet. •...
Troubleshooting SYMPTOMS POSSIBLE CAUSE Compressor will not start Check if the power cord has been plugged in. Check for blown fuse. Poor Performance Move the unit from direct sun light, and avoid installing heating devices near the unit. Install the unit in a well ventilated place with minimum of 6”...
Controller Instructions Digital controller model: PJEZ for cooler Display and functions During normal operation, the controller displays the value of the probe set using parameter/4(=1 ambient probe, default, = 2 second probe, = 3 third probe).In addition, the display has LEDs that indicate the activation of the control functions (see Table 1), while the 3 buttons can be used to activate/deactivate some of the functions(see Table 2).
Page 12
Controller Instructions Table of Functions activated by the buttons - Models S, X, Y, C (Table 2) Button Normal Operation Start Up Pressing the Button Alone Pressed Together More than 3 sec: toggle ON/ Start/Stop ON/OFF continuous cycle Down More than 3 sec: start/stop Pressed For 1 sec.
Page 13
Controller Instructions • To display/set the values of the parameter displayed, press SET, then UP/DOWN and finally SET to confirm the changes (returning to the parameter menu). To save all the new values and exit the parameter menu, press SET for 3 s. To exit the menu without saving the changed values (exit by timeout) do not press any button for at least 60 s.
Page 14
Controller Instructions Light Auxiliary output light Auxiliary output light Anti-sweat heater function active not active active Service No malfunction Malfunction (eg. EEPROM error or probe fault) HACCP HACCP function HACCP function HACCP alarm (HA and/or enabled HF) not enabled Continuous Enabled Not enabled Request...
Page 15
Controller Instructions Accessing the configuration parameter (type F) 1. Hold the “ ” button for more than 5 s (if there are active alarms, first mute the buzzer), the display will show the first modifiable “F” parameter. Modifying the parameters After having displayed the parameter, either type “C”...
Page 17
Parts Breakdown Model RE-CN-0045-HC 50032 Item No. Description Position Item No. Description Position Item No. Description Position AA766 Left Glass Door for 50032 AA809 K Strip for 50032 AB595 Filter Fixer for 50032 AA767 Front Grill Fixer for 50032 AA779...
Page 18
Parts Breakdown Model RE-CN-0009-HC 50033...
Page 19
Parts Breakdown Model RE-CN-0009-HC 50033 Item No. Description Position Item No. Description Position Item No. Description Position AE895 Castor Supporter for 50033 AB974 Handle for Installation Board for 50033 AA705 Condenser Fan Motor for 50033 Right Track for Installation Board for AE896 AE900 K Strip for 50033...
Page 20
Parts Breakdown Model RE-CN-0014-H 50035...
Page 21
Parts Breakdown Model RE-CN-0014-H 50035 Item No. Description Position Item No. Description Position Item No. Description Position AE907 Castor Supporter for 50035 AE911 K Strip for 50035 AB594 Filter for 50035 Right Track for Installation Board for AE896 26884 K Clip for 50035 AB595 Filter Fixer for 50035 50035...
Page 22
Parts Breakdown Model RE-CN-0023-HC 50036 Model RE-CN-0023-H 50037...
Page 23
Parts Breakdown Model RE-CN-0023-HC 50036 Model RE-CN-0023-H 50037 Item No. Description Position Item No. Description Position Item No. Description Position Right Track for Installation Board for Right Bracket for Evaporator Fan Cover AB953 AA748 Shelf Tag for 50036, 50037 AA793 50036, 50037 for 50036, 50037 AB954...
Page 24
Parts Breakdown Model RE-CN-0052-HC 50052...
Page 25
Parts Breakdown Model RE-CN-0052-HC 50052 Item No. Description Position Item No. Description Position Item No. Description Position 61219 Evaporator Fan Blade V154/22 for 50052 AE919 Air Pipe Protection Board for 50052 AA837 Light Box Plate for 50052 Evaporator Fan Motor EM3020-28-C04 / 68809 AA715 Axis Cover for 50052...
Page 26
Parts Breakdown Model FR-CN-0012-HC 50029...
Page 27
Parts Breakdown Model FR-CN-0012-HC 50029 Item No. Description Position Item No. Description Position Item No. Description Position AA848 Gasket for 50029 AA857 Upper Hinge for 50029 AB590 Outer Drain Pan for 50029 AA807 Right Bottom Hinge for 50029 AA695 Glass Door Handle for 50029 AE938 Compressor for 50029 AA810...
Page 28
Parts Breakdown Model FR-CN-0790-HC 50030...
Page 29
Parts Breakdown Model FR-CN-0790-HC 50030 Item No. Description Position Item No. Description Position Item No. Description Position AE943 Castor Installation Board for 50030 AB974 Handle for Installation Board for 50030 AE926 Thermostat Installation Plate for 50030 26247 Caster without Brake for 50030 AA856 Power Cord for 50030 AE946...
Page 30
Parts Breakdown Model FR-CN-1250-HC 50031...
Page 31
Parts Breakdown Model FR-CN-1250-HC 50031 Item No. Description Position Item No. Description Position Item No. Description Position AA927 Power Cord for 50031 AB978 Left Rail for Installation Board for 50031 AE955 Air Pipe Protection Board for 50031 AA124 Power Switch for 50031 AB134 Condenser for 50031 AA939...
Page 32
Parts Breakdown Model FR-CN-0045-HC 50075...
Page 33
Parts Breakdown Model FR-CN-0045-HC 50075 Item No. Description Position Item No. Description Position Item No. Description Position AE881 Back Grill for 50075 AA854 Shelf Tag for 50075 AE963 Air Pipe Protection Board for 50075 AA216 Drain Tube for 50075 AA249 Condenser Fan Motor Cover for 50075 AA787 LED Power Supply for 50075...
Warranty Registration Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at the perforation and then send to the address specified below. You can also register online by visiting: Merci d’avoir acheté...
Page 40
Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North American food service industry. Our success over these many years can be attributed to our commitment to strengthen and develop new and existing relationships with our valued customers and manufacturers.
Need help?
Do you have a question about the RE-CN-0045-HC and is the answer not in the manual?
Questions and answers