Check to add original data on thermal view.
Data Refresh Interval
It means the refresh interval of temperature information.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin (K).
Temperature Range
Select the temperature measurement range.
Version
View the version of current algorithm.
Calibration File Version
View the version of calibration file.
Alarm Interval
Set the alarm interval between two alarms.
Reflect Light Filter & Forklift Filter
Enable these functions if there is strong reflect light from sun or forklift in the scene. Or it
may cause false alarm.
Check Display Filtering Status, there will be an OSD when the filter is ON.
Click Restart to restart algorithm library.
Note
The settings vary according to different camera models.
4. Click Save.

3.3.2 Set Normal Mode

This function is used to measure the temperature of the whole scene and alarm.
Steps
1. Go to Configuration → Temperature Measurement → Basic Settings, and check Enable
Temperature Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to Configuration → Temperature Measurement → Advanced Settings, and select Normal.
4. Configure the parameters of normal mode.
Emissivity
Set the emissivity of your target. The emissivity of each object is different.
Distance
The distance between the target and the device.