Din Rail Mounting And Removal; Mounting Rules - Proconx SERIP-100 User Manual

Serial device server
Table of Contents

Advertisement

3. Connect the power supply cable and switch on the system power. Check if the
Power LED is lit.
4. Turn off system power.
5. Connect all I/O cables.
6. Once you are certain that all connections have been made properly, restore the
power.

DIN rail mounting and removal

The SERIP-100 gateway is designed to be mounted on a 35 mm DIN rail according to
DIN/EN 50022. The enclosure features a 35 mm profile at the back which snaps into the
DIN rail. No tools are required for mounting. Please observe the rules outlined in the
section called "Mounting rules".
1
2
Click
1

Mounting rules

The enclosure provides protection against solid objects according to IP 20 / NEMA Type 1
protection rating. When mounting the unit observe the following rules:
• No water splash and water drops
• No aggressive gas, steam or liquids
• Avoid dusty environments.
• Avoid shock or vibration
12
To mount the unit on a DIN rail, slot the top part of the
SERIP-100 into the upper guide of the rail and lower the
enclosure until the bottom of the red hook clicks into
place.
To remove the SERIP-100 from the DIN rail, use a screw
driver as a lever by inserting it in the small slot of the red
hook and push the red hook downwards. Then remove
the unit from the rail by raising the bottom front edge of
the enclosure.
2
UMSERIP100-2201