Siemens SIPROTEC 7SJ61 Manual page 408

Multi-functional protective relay with bay controller
Hide thumbs Also See for SIPROTEC 7SJ61:
Table of Contents

Advertisement

Appendix
A.8 Settings
Addr.
Parameter
4303
T START MAX
4304
T Equal
4305
I MOTOR NOMINAL
4306
MAX.WARM STARTS
4307
#COLD-#WARM
4308
Kτ at STOP
4309
Kτ at RUNNING
4310
T MIN. INHIBIT
4311
ROTOR OVERLOAD
4401
Load Jam Prot.
4402
Load Jam I>
4403
TRIP DELAY
4404
I Alarm
4405
ALARM DELAY
4406
T Start Blk.
7001
FCT 50BF
7004
Chk BRK CONTACT
7005
TRIP-Timer
7006
50BF PICKUP
7007
50BF PICKUP IE>
7101
FCT 79
7103
BLOCK MC Dur.
7105
TIME RESTRAINT
7108
SAFETY 79 ready
7113
CHECK CB?
7114
T-Start MONITOR
7115
CB TIME OUT
7116
Max. DEAD EXT.
7117
T-ACTION
7118
T DEAD DELAY
7127
DEADTIME 1: PH
7128
DEADTIME 1: G
7129
DEADTIME 2: PH
7130
DEADTIME 2: G
7131
DEADTIME 3: PH
7132
DEADTIME 3: G
7133
DEADTIME 4: PH
7134
DEADTIME 4: G
408
Function
C
48/66 Motorprot
1 .. 320 sec
48/66 Motorprot
0.0 .. 320.0 min
48/66 Motorprot
1A
0.20 .. 1.20 A
5A
1.00 .. 6.00 A
48/66 Motorprot
1 .. 4
48/66 Motorprot
1 .. 2
48/66 Motorprot
0.2 .. 100.0
48/66 Motorprot
0.2 .. 100.0
48/66 Motorprot
0.2 .. 120.0 min
48/66 Motorprot
ON
OFF
Alarm Only
48/66 Motorprot
OFF
ON
Alarm Only
48/66 Motorprot
1A
0.50 .. 12.00 A
5A
2.50 .. 60.00 A
48/66 Motorprot
0.00 .. 600.00 sec
48/66 Motorprot
1A
0.50 .. 12.00 A
5A
2.50 .. 60.00 A
48/66 Motorprot
0.00 .. 600.00 sec
48/66 Motorprot
0.00 .. 600.00 sec
50BF BkrFailure
OFF
ON
50BF BkrFailure
OFF
ON
0.06 .. 60.00 sec; ∞
50BF BkrFailure
50BF BkrFailure
1A
0.05 .. 20.00 A
5A
0.25 .. 100.00 A
50BF BkrFailure
1A
0.05 .. 20.00 A
5A
0.25 .. 100.00 A
79M Auto Recl.
OFF
ON
79M Auto Recl.
0.50 .. 320.00 sec; 0
79M Auto Recl.
0.50 .. 320.00 sec
79M Auto Recl.
0.01 .. 320.00 sec
79M Auto Recl.
No check
Chk each cycle
0.01 .. 320.00 sec; ∞
79M Auto Recl.
79M Auto Recl.
0.10 .. 320.00 sec
0.50 .. 1800.00 sec; ∞
79M Auto Recl.
0.01 .. 320.00 sec; ∞
79M Auto Recl.
0.0 .. 1800.0 sec; ∞
79M Auto Recl.
79M Auto Recl.
0.01 .. 320.00 sec
79M Auto Recl.
0.01 .. 320.00 sec
79M Auto Recl.
0.01 .. 320.00 sec
79M Auto Recl.
0.01 .. 320.00 sec
79M Auto Recl.
0.01 .. 320.00 sec
79M Auto Recl.
0.01 .. 320.00 sec
79M Auto Recl.
0.01 .. 320.00 sec
79M Auto Recl.
0.01 .. 320.00 sec
Setting Options
Default Setting
10 sec
1.0 min
1.00 A
5.00 A
2
1
5.0
2.0
6.0 min
ON
OFF
2.00 A
10.00 A
1.00 sec
1.80 A
9.00 A
1.00 sec
10.00 sec
OFF
OFF
0.25 sec
0.10 A
0.50 A
0.10 A
0.50 A
OFF
1.00 sec
3.00 sec
0.50 sec
No check
0.50 sec
3.00 sec
100.00 sec
∞ sec
1.0 sec
0.50 sec
0.50 sec
0.50 sec
0.50 sec
0.50 sec
0.50 sec
0.50 sec
0.50 sec
C53000-G1140-C210-1, Release date 02.2008
Comments
Maximum Permissible Starting
Time
Temperature Equalizaton Time
Rated Motor Current
Maximum Number of Warm
Starts
Number of Cold Starts - Warm
Starts
Extension of Time Constant at
Stop
Extension of Time Constant at
Running
Minimum Restart Inhibit Time
Rotor Overload Protection
Load Jam Protection
Load Jam Tripping Threshold
Load Jam Trip Delay
Load Jam Alarm Threshold
Load Jam Alarm Delay
Load Jam Blocking after motor
start
50BF Breaker Failure Protection
Check Breaker contacts
TRIP-Timer
50BF Pickup current threshold
50BF Pickup earth current
threshold
79 Auto-Reclose Function
AR blocking duration after
manual close
79 Auto Reclosing reset time
Safety Time until 79 is ready
Check circuit breaker before AR?
AR start-signal monitoring time
Circuit Breaker (CB) Supervision
Time
Maximum dead time extension
Action time
Maximum Time Delay of Dead-
Time Start
Dead Time 1: Phase Fault
Dead Time 1: Ground Fault
Dead Time 2: Phase Fault
Dead Time 2: Ground Fault
Dead Time 3: Phase Fault
Dead Time 3: Ground Fault
Dead Time 4: Phase Fault
Dead Time 4: Ground Fault
SIPROTEC, 7SJ61, Manual