Induction Mode-Image Stabilization Time - ELZAB DE2106 Setting Manual

Table of Contents

Advertisement

61 / 134

Induction mode-image stabilization time

In the induction mode, when the scanner stops reading the code, it will enter a process of
re-adapting to the changes in the reading environment (image). After the image is
stabilized, it will enter the induction state and wait for the barcode to appear. By modifying
the image stabilization timeout, the time to adapt to the environment can be adjusted. The
setting range of image stabilization time is 0~1600MS, and the default image stabilization
time is 60MS.
The image stabilization time is 60ms
Image stabilization time 500ms
Image stabilization time 1000ms
Modify the image stabilization time
Example: Set the image stabilization time to 500MS.
1. Scan the "Enable Setting" setting code (you don't need to scan when it is turned on);
2. Scan the "modify image stabilization time" setting code;
3. Scan the "5", "0" and "0" setting codes in "Appendix-Data Code" in turn;