Inductive / auto-sensing reading mode

In the auto-sensing mode, the reading module will monitor the captured images. When
the scene changes, it will be read within the "single reading time" within a limited time.
After the reading is successful, it will output information or time out, and then re-enter the
monitoring The state of the scene change.
When the reading module works in this mode, it can also respond to the trigger level and
enter the reading state. After the trigger level is cancelled, the reading is successful, or the
timeout, it will re-enter the state of monitoring scene changes. Before entering the
monitoring state again, the trigger level needs to be cancelled.
auto-sensing mode

Induction mode-single reading time limit

Single reading time limit: it is the longest time allowed to maintain the shooting and
reading attempt after the scene change is monitored and the reading state is entered, and
the reading is not successful. When this time is exceeded, the reading state will return to
the monitoring state. The setting range of the single reading time is 1000~3600000ms,
and the default time is 3000ms.