TECHNICAL DESCRIPTION
Data
Serial number
Meter specific data
Meter reading
Target volume
Max flow**
Min. flow
Water temperature*
Meter temperature
Info codes
Historical info codes
Reverse volume
Target date
Date/time stamp
Battery left
Radio Disabled
*Measuring the water temperature is only valid for meter sizes 1.6, 2.5 and 4.0 m
** 'Max flow' is from meter size:
1.6 - 16 m³/h always in l/h
25-100 m³/ h, the flow is indicated in m³/h (2 decimals) - from this SW revision and forward:
SW rev.: T1 (wireless M-bus),
G1(wired M-bus)
1.6 - 63 m³/h – Sigfox always in l/h
Module 46: If encryption has been selected, when submitting the order, all variable data will be encrypted
with '128 bits AES counter mode' encryption.
Kamstrup A/S recommends encryption.
18
The meter's serial number. The serial number will never be encrypted.
Identification as cold water meter
Kamstrup's specific Wireless M-Bus producer-ID
Information on length and format of data package
Information on encryption of data package
The current meter reading from the meter's legal register
st
Meter reading of the 1
Meter reading of the first day of the year
Maximum flow, which has been measured during the year, month or day
depending on the selected R- Package
Minimum flow, which has been measured during the year, month or day
depending on the selected R- Package
Minimum, max or average water temperature for the last completed year,
month or day – depending on the choice of the 'R-package'
Minimum, maximum or average ambient/meter temperature, latest year,
month or day– depending on choice of 'R'- value
Info codes which are active at present
Info codes which have been active within the latest 30 days including
information on how long they have been active – on a scale of 1-7
The V1 reverse register. Registration of volume of the water running in the
wrong direction.
Date of target volume storage in the monthly log. The date is the last day of
the month – i.e. a monthly log created at midnight the night before d.
1/8/2012, will have target date 31/7 2012.
Time and date for reading
Indicates battery capacity – how many days approx. are left
Only module 99 and 98
Explanation
of the month
Kamstrup A/S • Technical Description • 5512-1242_N1_GB • 10.2019
flowIQ® 3100
3
/h
Need help?
Do you have a question about the flowIQ 3100 Series and is the answer not in the manual?