NetApp StorageGRID SG1000 Hardware Installation And Maintenance Manual page 71

Hide thumbs Also See for StorageGRID SG1000:
Table of Contents

Advertisement

ii. Place the drive on a
static-free, level surface.
The handle on the drive springs open partially, and the drive releases from the slot.
5. Open the handle, slide the drive out, and place it on a static-free, level surface.
6. Press the release button on the replacement drive before you insert it into the drive slot.
The latch springs open.
i. Insert the drive.
7. Insert the replacement drive in the slot, and then close the drive handle.
Do not use excessive force while closing the handle.
Attention:
When the drive is fully inserted, you hear a click.
The drive is automatically rebuilt with mirrored data from the working drive. You can check the
status of the rebuild by using the Grid Manager. Select Nodes. Then select
Hardware. The Storage RAID Mode field contains a "rebuilding" message until the drive is
completely rebuilt.
8. Contact technical support about the drive replacement.
Technical support will provide instructions for returning the failed drive.
i. Press the
release button.
Attention: Ensure
that the tray handle
is fully open before
you attempt to slide
the drive out.
ii. Close the drive tray handle.
Note: Do not use excessive force
while closing the handle.
Maintaining the SG1000 appliance | 71