Summary of Contents for NetApp StorageGRID SG100

  • Page 1 Hardware procedures StorageGRID Appliances NetApp August 30, 2024 This PDF was generated from https://docs.netapp.com/us-en/storagegrid-appliances/sg100-1000/verify- component-to-replace-sg100-and-sg1000.html on August 30, 2024. Always check docs.netapp.com for the latest.
  • Page 2: Table Of Contents

    Table of Contents Hardware procedures.............. ...
  • Page 3: Hardware Procedures

    Hardware procedures Verify component to replace in the SG100 or SG1000 If you are unsure which hardware component to replace in your appliance, complete this procedure to identify the component and the location of the appliance in the data center. Before you begin •...
  • Page 4: Replace Sg100 Or Sg1000 Appliance Cover

    2. Identify the chassis with the component that needs to be replaced. a. From the Grid Manager, select NODES. b. From the table on the Nodes page, select the appliance Storage Node name with the failed component. c. Select the Hardware tab. Check the Compute controller serial number in the StorageGRID Appliance section.
  • Page 5 Wrap the strap end of an ESD wristband around your wrist and secure the clip end to a metal ground to prevent static discharge when working inside the appliance. After replacing the part, return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the Part Return &...
  • Page 6: Replace One Or Both Power Supplies In The Sg100 Or Sg1000

    2. Rotate the cover latch forward and down until it stops and the cover fully seats into the chassis. Verify that there are no gaps along the front edge of the cover. If the cover is not fully seated, you might not be able to slide the appliance into the rack. 3.
  • Page 7 The power supplies for the SG1000 are identical. Steps 1. If you are replacing only one power supply, you don’t need to shut down the appliance. Go to the Unplug the power cord step. If you are replacing both power supplies at the same time, do the following before unplugging the power cords: Shut down the appliance.
  • Page 8: Replace Fan In Sg100 Or Sg1000

    7. If you are replacing both power supplies, repeat steps 2 though 6 to replace the second power supply. Connect the power cords to the replaced units and apply power. After replacing the part, return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the Part Return & Replacements page for further information.
  • Page 9 Steps 1. Shut down the appliance. a. Log in to the grid node: i. Enter the following command: ssh admin@grid_node_IP ii. Enter the password listed in the file. Passwords.txt iii. Enter the following command to switch to root: su - iv.
  • Page 10 Use the BMC interface to monitor boot-up status. 11. Confirm that the appliance node appears in the Grid Manager and that no alerts appear. After replacing the part, return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the Part Return &...
  • Page 11: Replace Drive In Sg100 Or Sg1000

    Replace drive in SG100 or SG1000 The SSDs in the services appliance contain the StorageGRID operating system. Additionally, when the appliance is configured as an Admin Node, the SSDs also contain audit logs, metrics, and database tables. The drives are mirrored using RAID1 for redundancy.
  • Page 12: Replace The Cmos Battery In An Sg100 Or Sg1000

    Appliance Node Storage RAID Mode field contains a “rebuilding” message until the drive is completely rebuilt. After replacing the part, return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the Part Return & Replacements page for further information.
  • Page 13 • You have physically located the SG100 or SG1000 appliance where you are replacing the CMOS battery in the data center. controlled shutdown of the appliance is required before removing the appliance from the rack. • You have disconnected all cables and removed the appliance cover.
  • Page 14 Reinstall the CMOS battery Install the replacement CMOS battery into the socket on the system board. Before you begin • You have the correct replacement CMOS battery (CR2032). • You have removed the failed CMOS battery. Steps 1. Wrap the strap end of the ESD wristband around your wrist, and secure the clip end to a metal ground to prevent static discharge.
  • Page 15: Replace An Sg100 Or Sg1000

    c. Enter the following command to switch to root: su - d. Enter the password listed in the file. Passwords.txt 11. Restore BMC network connectivity for the appliance. There are two options: ◦ Use static IP, netmask, and gateway ◦ Use DHCP to obtain an IP, netmask, and gateway a.
  • Page 16 1. Display the current configurations of the appliance and record them. a. Log in to the appliance to be replaced: i. Enter the following command: ssh admin@grid_node_IP ii. Enter the password listed in the file. Passwords.txt iii. Enter the following command to switch to root: su - iv.
  • Page 17: Relocate Sg100 Or Sg1000 In Cabinet Or Rack

    8. Confirm that the appliance node appears in the Grid Manager and that no alerts appear. After replacing the part, return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the Part Return & Replacements page for further information.
  • Page 18 6. Optional: If you are fully removing the appliance from the cabinet or rack, follow the instructions for the rail kit to remove the appliance from the rails. After replacing the part, return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the Part Return &...
  • Page 19 Don’t attach the front bezel until after you power on the appliance. 2. Tighten the captive screws on the appliance front panel to secure the appliance in the rack. 3. Wrap the strap end of the ESD wristband around your wrist, and secure the clip end to a metal ground to prevent static discharge.
  • Page 20 NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp.