Table 8-1: Parallel Connector Pin Assignments (Continued)
Pin
Signal
14
17
AUTO FEED XT*
Inverted logic:
signal is active
when low.
15-17
N/A
LOGIC GROUND
18
N/A
VCC
N/A
18
HOST LOGIC
HIGH
19–30
19–35
GND
31
14
INIT*
signal is active
when low
32
4
ERROR*
Inverted logic:
signal is active
when low
33–35
N/A
LOGIC GROUND
N/A means non-applicable.
Direction
Description
In
Host Busy when
Logic Ground
300 mA of 5 V +/ - 5%
In
Driven by the host.
Return
These pins are grounded signals used as twisted pairs with the
data and control signals. GND is often called a logic ground, and a
fusible link isolates it from chassis ground to offset any large
ground shifts when the printer and computer are on different
circuits.
In
The rising edge of a negative pulse on this line causes the printer
to initialize. The printer synchronizes this function with the
received data. On the falling edge of INIT*, the printer drives the
BUSY interface signal active. On the rising edge of INIT*, the
printer:
• Prints all received data
• Displays RESET
• Initializes
• Deactivates the BUSY signal
To disable INIT* processing, set
operator panel or through MarkVision Professional. Refer to your
printer user documentation for more information.
Out
This signal indicates a printer error condition. The signal level
becomes low when the printer is:
• In paper exception status
• Not ready because of an operator panel command to stop
• Not ready because of a software command to stop
• Not ready because of a software command for manual feed
This signal is activated approximately 5 seconds after one of the
above conditions sets BUSY.
Not used.
8-10
Advanced Status
is
On
.
Honor Init
to
Interfaces
Off
from the printer