Lexmark J110 Reference Manual page 245

Lexmark j110: reference guide
Hide thumbs Also See for J110:
Table of Contents

Advertisement

Table 4-14: PostScript Emulation System Parameters (Continued)
Key
1
PrinterCode
PrinterName
RamSize
RealFormat
Revision
1
SearchBuiltinFontsFirst
1
SerialNumber
StartJobPassword
StartupMode
1
StaticRamSize
SystemParamsPassword
1
These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 2016.
2
These parameters are available with the Adobe PostScript Language Supplement 3010.
3
These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 3010.
Type
Definition
string
(Read-only) Firmware version of the printer controller card.
string
Initialized from the printer name stored in NVRAM (the default
name of the printer). If this parameter is set to a zero length
string, the PrinterName is set to the value of the product
string in statusdict.
Legal value: Any string of 32 or fewer non-null characters.
integer
(Read-only) Total amount of memory (in bytes) installed in the
printer.
string
(Read-only) Preferred representation for real numbers in
binary encoded tokens.
integer
(Read-only) The current revision level of the machine-
dependent portion of PostScript emulation.
boolean
Controls the device search order the interpreter uses to
locate fonts.
string
(Read-only) Serial number of your printer.
string
(Write-only) Controls the ability of the startjob operator to
alter initial Virtual Memory (VM).
Legal value: Any integer or string of 32 or fewer non-null
characters. An integer is converted to a string.
integer
Controls the system start file (Sys/Start) during PostScript
emulation initialization. Also, controls the job start file
(Job/Start) before each print job.
0
Disable use of Sys/Start file and Job/Start file.
1
Sys/Start file executes (if present on disk or flash).
10 Job/Start file executes before each user job.
11 Both files run (a combination of 1 and 10).
Legal Values: 0 <= x <= 255. Values other than the four listed
are equivalent to 0.
Note: If both flash and disk have a Sys/Start file and Job/Start
file, the value of the SearchOrder for the two devices
determines which file is executed.
integer
(Read-only) Amount of static memory (in bytes) on the
controller board.
string
(Write-only) Controls the ability of setsystemparams to
change the values of system parameters and setdevparams
to change the values of device parameters.
Legal value: Any integer or string of 32 or fewer non-null
characters. An integer is converted to a string.
4-78
PostScript

Advertisement

Table of Contents
loading

This manual is also suitable for:

T522T620T520T622W820C720 ... Show all

Table of Contents