Double Level Mode; Setting Welding Parameters - Cebora KINGSTAR 400 TS Instruction Manual

Wire welding machine
Table of Contents

Advertisement

Available languages

Available languages

4�3�2

DOUBLE LEVEL mode

To choose the DOUBLE LEVEL mode, select pushbutton DF:
FREQUENCY
DUTY CYCLE
SPEED DIFFERENCE
ARC CORRECTION
UP SLOPE
DOWN SLOPE
4�3�3

Setting welding parameters

DG/DH quick pushbuttons for selecting welding parameters
3301065/A
MIN.
MAX.
0.1 Hz
10 Hz
25%
75%
0.1 m/min
3.0 m/min
-9.9
+9.9
0.1
10.0
0.1
10.0
Adjusting inductance. This can be selected using pushbutton DG. This function
can be used to switch between a narrow, hard arc with deep penetration (negative
values) and a broad, smooth arc (positive values). The adjustment can range
between +/- 9.9, 0 is the factory setting.
Adjusting arc length. This can be selected using pushbutton DH. If necessary, arc
length (welding voltage) can be corrected by +/- 9.9 V for the specifi c welding job,
0 is the factory setting.
Press pushbutton (DF) on the display and it
becomes possible to activate the function using
the ON pushbutton, which turns orange when
pressed.
Active in synergic MIG/MAG processes only.
This mode involves changing wire speed (and
consequently also current intensity) between two
levels. Before setting double level welding, make a
short bead to determine the wire speed and hence
the current to obtain the optimum bead penetration
and width for the type of weld to be performed. In
this way the wire feed speed is determined; the set
SPEED DIFFERENCE parameter will be added to
or subtracted from this value. Before start working
you should not forget that for a correct bead, the
minimum overlap between one mesh and another
must be 50%.
Double level frequency. Frequency is the number
DEF.
of periods per second expressed in Hz. Period
means the duration of a complete speed high-low
1.5 Hz
variation cycle.
Duty cycle� Duration of the high speed/current in
50%
relation to the overall period duration.
Speed difference. Amplitude of the speed change
1.0 m/min
in m/min in relation to the reference speed.
Arc correction. Sets a higher speed/current arc
0.0
length.
Down/Up Slope. The up or down ramp set for the
0.8
transition from the minimum motor speed value to
the maximum value and vice versa.
0.3
DEFAULT to reset all the parameters to the factory
settings.
77/109

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kingstar 520 tsKingstar 400 ts robotKingstar 520 ts robot372.00374.00372.80 ... Show all

Table of Contents