Start Mode - Cebora KINGSTAR 400 TS Instruction Manual

Wire welding machine
Table of Contents

Advertisement

Available languages

Available languages

4�3

Start mode

To choose the start mode, select pushbutton DE (see Fig� 10).
Start modes are the same for all MIG/MAG processes�
The START control for manual applications is available in the wire feeder and on the torch attachment. It can be
activated using the corresponding pushbutton on the torch as well as on the remote control connector.
3301065/A
Set the desired start mode using the appropriate pushbuttons.
When start mode has been selected, the associated section turns
orange.
2 stroke mode
Mode appropriate for short welding bursts or automated robotised welding.
Welding is started by pressing the START pushbutton and ends when the pushbutton is
released.
HSA and CRA functions can be activated in 2 stroke mode.
Automatic mode or 4 stroke mode
Appropriate mode and perform long-term welding. Starting and stopping are controlled
by pressing and releasing the torch START pushbutton. Not available with Robot interface
activated. HSA and CRA functions can be activated in 4 stroke mode.
3 level mode
When the arc strikes, the current is set to the fi rst level. As long as the START pushbutton
is pressed, the current remains on the fi rst level. Upon releasing the START pushbutton,
the current passes from fi rst to second level within the slope time; once the second level is
reached, this is maintained. The next time the START pushbutton is pressed, the welding
current will be adjusted to the 3rd level within the set slope time. When the START pushbutton
is released welding stops and the post-fl ow procedure is run. The HSA and CRA functions
are inhibited in 3-level mode
Not available with Robot interface activated.
HSA mode
By activating HSA mode, the operator can adjust the fi rst current level, the time spent at the
fi rst current level and the fi rst level ramp time at the fi nal welding current.
When the START command is activated, the set values are automatically carried out.
CRA mode
By activating CRA mode, the operator can adjust the fi nal current level (crater current), the
time spent at fi nal current level and the time of the ramp down from the welding current to
the fi nal current. When the START command is deactivated, the set values are automatically
carried out.
SPOT mode
Spot welding mode (See section 4.3.1).
Start pushbutton pressed
Start pushbutton released
75/109

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kingstar 520 tsKingstar 400 ts robotKingstar 520 ts robot372.00374.00372.80 ... Show all

Table of Contents