3.19 Modifying protection settings

Control panel
Function
To modify a number of protection settings. Consult the menu flow in section
Procedure
Starting from the Main screen (see
• Press key "Menu" (F1).
• Press key (1) until "Modify settings" is shown.
• Activate the menu by pressing key "Select" (F2).
• The first item ("Regulation") is shown. Press keys (1) to scroll to "Protection".
• Press key "Select" (F2) and use keys (1) to scroll to the setting to be modified.
• For each setting, the modifying procedure is similar to the example below.
Modifying the shut-down setting for the oil pressure
• Consult the section above for selecting the option "Protection".
• Press key "Select" (F2). The first item is shown ("Oil pressure").
• Press key "Select" (F2). A display similar to that shown below will appear:
Oil
Programmable settings
Shutdown
Menu
F1
The example indicates:
• The name of the sensor ("Oil") and the actual measured value ("2.5 bar")
• The type of parameter ("Shutdown"), the level type ("Minimum level") and the actual programmed
value ("1.2 bar")
• After pressing the key "Modify" the value of the parameter starts blinking and the functions of the
keys (F1, F2 and F3) change into "Program", "Limits" and "Cancel" respectively.
• Modify the value by means of scroll keys (1).
2920 1815 04
Main screen
menu):
Minimum
Modify
F2
Control
programs.
2.5 bar
1.2 bar
F3
61