Humidity too high when unit is not running
Possible Cause
Unit needs to run to dehumidify
Humidity too high when unit is running and cooling
Possible Cause
Too much moisture in cellar
Other Miscellaneous Problems
Unit operates but the power switch light is not ON
Possible Cause
Bulb is burned out
Unit is leaking water
Possible Cause
Piping from unit to drain is trapped
Trap plugged
Condensate pan plugged
Unit not level
Unit is running properly, but the sound of the unit is objectionable
Possible Cause
Noise is from airflow
Noise if from unit
54
Solution
Run unit. Seal openings around doors (gasket
and sweep)
Solution
Poor vapor barrier installation
Humidifier malfunction refer to the humidifier
instructions.
Add dehumidifier to surrounding space
Solution
Replace bulb
Solution
Re-pipe to remove external traps
Clean trap
Remove blockage and clean
Level with shims
Solution
Redirect airflow
Add baffles
Add insulated ductwork
Add sound baffle between unit and occupied