Horizontal Blade / Vertical Blade ASSYs
Step
2. Remove the vertical blade
ASSYs.
1
Unfasten the 2 hooks
on the front.
2
Unfasten the 3 hooks of
the vertical blade ASSY
by pressing them with a
flat screwdriver.
3
Remove the vertical
blade ASSY.
4
Remove the other
vertical blade ASSY in
the same way.
6
Procedure
Hook
Hook
Points
Slide the front hooks to the
right/left to unfasten easily.
(R20062)
(R20063)
Each vertical blade ASSY
has 6 fins. It is not possible
to replace the fins
individually.
The vertical blade ASSY is
not marked for difference
between right and left.
(R20064)