  • Page 1 DAIKIN 3P665364-8T M22P098B DAIKIN ROOM AIR CONDITIONER OPERATION MANUAIL <...INVERTER> MODELS: A/D/F/G/MTKY50UV16V3A 3P665364-8 T M22P098B...
  • Page 2: Safety Precautions

    Safety Precautions • Keep this manual where the user can easily find it. &CAUTION • Read the precautions in this manual carefully before operating the unit. • Do not use the air conditioner for purposes other than • The precautions described herein are classified as WARNING those for which it is intended.
  • Page 3: Name Of Parts

    Read before Operation Name of Parts ■ Indoor Unit 1. Front panel 2.Air inlet 3.Air filter _I --= _� 4.Accessory filter * 5. Model name plate 6. Indoor temperature sensor: C- 1 � :�- • Detects the air temperature around the unit. 7.Display 8.
  • Page 4: Ontimer Button

    ■ Read before Operation Name of Parts ■ Remote Controller B� _,=------ 1 1. Signal transmitter: • Send signals to the indoor unit. 2. Display (LCD): � J • Display the current setting..,..,. 3. ON/OFF button: • Press this button once to start operation. 7-----,.,-.c,,P O WERCHILL <!l •...
  • Page 5: Preparation Before Operation

    ■ ■ Read before Operation Preparation before Operation &CAUTION Incorrect handling of batteries can result in injury from battery leakage, rupturing or heating, or lead to equipment failure. Please observe the following precautions and use safely. • If the solution from the batteries should get in the eyes, do not rub the eyes. Instead, immediately flush the eyes with tap water and seek the attention of a medical professional.
  • Page 6: Dry · Cool · Fan Operation

    Operation DRY · COOL · FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. ■ ■ To start operation To stop operation 1.
  • Page 7 Operation Adjusting the Airflow Rate /SMELL PROOF/CHILD LOCK operation Adjusting the airflow rate You can adjust the airflow rate to increase your comfort. ■ To change the airflow rate setting □ □ ( +FA N) . • l+FANJ Each pressing of changes the airflow rate setting in sequence.
  • Page 8: Adjusting The Airflow Direction

    Operation Adjusting the Airflow Direction You can adjust the airflow direction to increase your comfort. �CAUTION • Always use a remote controller to adjust the angles of the flaps. Moving the flaps forcibly by hand may cause a malfunction. • Be careful when adjusting the louvres. Inside the air outlet, a fan is rotating at a high speed. Up and down airflow direction ■...
  • Page 9 ■ ■ ■ Operation COANDA/POWER CHILL & ECONO Operations ECONO Operation COANDA Operation ECONO operation enables efficient operation Directs airflow upward.This function prevents air by limiting the maximum power consumption. from blowing directly at users. This function is useful to prevent the circuit To start COAN DA operation COANDA breaker from tripping when the unit operates...
  • Page 10 ■ ■ ■ ■ ■ Operation TIMER/GOOD SLEEP Operations TIMER Operation GOOD SLEEP Operations Timer functions are useful for automatically To use �22 D SLEEP OFF TIMER operation. switching the air conditioner on or off in the 1. Press CJD during COOL operation. morning or at night.
  • Page 11 Operation LED BRIGHTNESS Control Operation The brightness of the indicator lamp can be adjusted H(high), L(low), or OFF. To set the brightness setting mode. ■ Press(<:�sw,NaJ for more than 5 second's. • is displayed on the LCD of remote. ■ Press will show the last memory setting of brightness intensity of indicator lamp.
  • Page 12: Care And Cleaning

    Care Care and Cleaning &CAUTION • Before cleaning, be sure to stop the operation and turn off the circuit breaker. • Do not touch the aluminium fins of the indoor unit. If you touch those parts, this may cause an injury. •...
  • Page 13: Air Filter

    Care Care and Cleaning Air filter 1. Pull out the air filters. • Open the front panel. • Push the filter tab at the centre of each air filter a little upwards, then pull it down. 2. Wash the air filters with water or clean them with a vacuum cleaner.
  • Page 14 Care Care and Cleaning Accessory filter I Filter type: Titanium apatite deodorizing air-purifying filter/ Air-purifying filter/ Anti microbial filter. [Maintenance] The accessory filters can be renewed by washing them with water once every 6 months. We recommend replacing them once every 3 years. 1.
  • Page 15: Troubleshooting

    ■ ■ ■ ■ ■ Troubleshooting Troubleshooting These cases are not problems. T he following cases are not air conditioner troubles but have some reasons. You may just continue using it. Case Explanation Operation does not start soon. • This is to protect the air conditioner. •...
  • Page 16 ■ ■ ■ ■ ■ ■ Troubleshooting Troubleshooting Case Explanation The indoor unit gives out • The room odour absorbed in the unit is discharged with the airflow. We recommend you to have the indoor unit cleaned. Please consult your service centre. odour.
  • Page 17 Troubleshooting Troubleshooting Call your service centre immediately. & WARNING ■ When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker. Continued operation in an abnormal condition may result in problems, electric shock or fire. Consult the service centre where you bought the air conditioner.
  • Page 18 • A short beep indicates non-corresponding codes. • To cancel the code display, hold down (cANcaJ for about 5 seconds. The code display also cancels itself if the button is not pressed for 1 minute. DAIKIN INDUSTRIES, LTD. Head office: Osaka Umeda Twin Towers South...
  • Page 21: Trial Operation And Testing

    Trail Operation And Testing 1. Trial operation and testing • Check that the inter-unit wire is correctly connected. • Trial operation should be carried out in COOL operation. 1-1 Measure the supply voltage and make sure that it is within the specified range. 1-2 Select the lowest programmable temperature.
  • Page 22: Outdoor Unit

    Outdoor Unit Purging Air And Checking Gas Leakage WARNING ------------------------- • Do not mix any substance other than the specified refrigerant (R32) into the refrigeration cycle. • When refrigerant gas leaks occur, ventilate the room as soon and as much as possible. •...
  • Page 23: Refrigerant Piping

    Outdoor Unit Installing The Outdoor Unit • When installing the outdoor unit, refer to "Precautions for Selecting a Location" and the "Outdoor Unit Installation Diagram" . ., ..Flaring The Pipe End [ill ,{t WARNING C"' =ctly at � � Removeburrs. Incomplete flaring may result refrigerant gas leakage.
  • Page 24 Binding Of Insulation Pipe 1. The slit direction should be upward. Sectional view 2. It should be sealed with vinyl tape without any gap. lraJiaticn Hml.lnwlationpipocover -�· taii• 3. Do not over tighten with vinyl tape. Comnuilca!lonwtre {B���I llttiebottom.) V�tape Ge•pipe Wrap vinyl tape with the slit of the heat insulation pipe cover facing up so that there are no gap .
  • Page 25: Indoor Unit

    Indoor Unit Wiring 1) Strip wire ends (15mm). Terminal block 2) Match wire colours with terminal numbers on indoor and outdoor unit's terminal blocks and firmly screw wires to the corresponding terminals with the screw. 3) Connect the earth wires to the corresponding terminals. Attach the earth wire so that it is not connected to the fan motor connector.
  • Page 26: Installing The Indoor Unit

    Indoor Unit Installing The Indoor Unit ( Right-Side, Right-Back or Right-Bottom Piping ) Open the front panel, open the Front grille (If Required), then open the service lid.(Referto Installation Tips.) .. . Shape the refrigerant pipes. @Mountlng Pass the drain hose and refrigerant pipes through the wall hole. Hang the indoor unit on (A) mounting Plate Refrigerant pipes...
  • Page 27: Installing The Mounting Plate

    Indoor Unit Installing The Mounting Plate • The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall.
  • Page 28: Installation Tips

    ■ ■ ■ Installation Tips Installing and Removing the indoor unit. � CAUTION---------- • Installation method 1) Push up. Be sure to wear protection gloves. Hook the claws of the bottom frame to the mounting plate. If the claws are difficult to hook, remove the front grille. •...
  • Page 29: Indoor/Outdoor Unit Installation Diagram

    Indoor/outdoor Unit Installation Diagram -:=r,r • The mounting plate should be installed on a wall which can support the weight of the indoor unit. ,,,-, -- @Mountlngplatefixingscr..wM4•25L(7pcs.) �ountingpl • tefixingscrswM4•25L(7pcs.) For type (D®@@) (Refer table no. 4) For type@(Refer table no. 5) Note: Before installation, mounting plate size &...
  • Page 30: Precautions For Selecting A Location

    Accessories ® ~ ® ITEM ITEM QTY. Remarks QTY. Remarks ® ® Mounting plate Remote controller holder fixing screw (M3 x 20L @ Mounting plate fixing screw (M4 x 25U CD 4-Core wire (3. 7M) 617· © Wireless Remote Controller ®...
  • Page 31 Safety Precautions • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail. • Meaning of WARNING and CAUTION notices � WARNING Failure lo follow these instructions properly may result in personal injury or loss of life. �...