Drain Pan Unit / Swing Motor - Daikin ATC25QRV16 Service Manual

Removal procedure
Table of Contents

Advertisement

Si041402EC

7. Drain Pan Unit / Swing Motor

Warning
Step
1. Remove the drain pan
unit.
1
Remove the screw at
the right side of the
drain pan unit.
2
Press the right side of
the drain pan unit and
twist the left side.
3
Remove the drain pan
unit from the indoor
unit.
2. Remove the swing motor.
1
Remove the screw of
the swing motor.
2
Remove the shaft, and
then the swing motor.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Drain pan unit
Drain Pan Unit / Swing Motor
When reassembling, make
sure that the hook at the left
side is fitted in the groove.
(R20084)
(R20085)
(R23421)
Shaft
Swing motor
(R20087)
Points
13