Summary of Contents for Bosch AVENAR panel

  • Page 1 AVENAR panel System manual...
  • Page 3: Table Of Contents

    Topologies in Local Security Network Failure handling in Local Security Network Redundancy 3.6.1 AVENAR panel 8000 with panel redundancy 3.6.2 Remote keypad as redundant panel controller Achievable cable length with LSN 0300 A Achievable cable length with LSN 1500 A Configuration with BCM-0000-B modules 3.10...
  • Page 4 | Table of contents AVENAR panel Controlling Extinguishing Systems Additional documentation 8.3.1 Frame installation housings, mounting frames and installation kits 8.3.2 Wall mounting housings and installation kits 8.3.3 Accessories for housing 8.3.4 Panel rails 8.3.5 Power supply units 8.3.6 Panel controller | remote keypad 8.3.7...
  • Page 5: Safety

    Warning! Risk of overheating Bosch provides no front door for this system. You are not allowed to operate the system with a front door. Otherwise, the system can overheat, because the air vents are blocked. Notice! Bosch Sicherheitssysteme GmbH uses Open Source Software.
  • Page 6 | Safety AVENAR panel Notice! Consider national and local regulations when installling and operating the fire system. 2022-07 | 5.0 | F.01U.378.910 Bosch Sicherheitssysteme GmbH System manual...
  • Page 7: Avenar Panel Series

    AVENAR panel 8000 uses functional modules that are clicked in a slot on a rail. AVENAR panel 2000 comes as a kit in a housing. The functional modules can be plugged onto the rail inside the housing.
  • Page 8 Features – Completely modular fire panel, expandable up to 32 loops for AVENAR panel 8000 and up to 4 loops for AVENAR panel 2000, provides customized solutions for medium to large size applications –...
  • Page 9 AVENAR panel AVENAR panel series | en 1 Panel controller 6 PRD 0004 A Panel Rail Long 2 Fire brigade peripheral module 7 Power supply unit 3 HBC 0010 A Panel Housing for 10 8 Power supply bracket modules 4 Batteries...
  • Page 10 | AVENAR panel series AVENAR panel Functional modules are independent encapsulated units. They are placed into a slot of a panel rail. The power supply and the data traffic with the panel are therefore provided automatically. The module is identified by the panel with no further settings and operates in the default operating mode (plug and play).
  • Page 11: Panel Controller

    AVENAR panel AVENAR panel series | en Panel controller The panel controller is the central component of the fire panel. All messages are shown on the color display. The entire system is operated via a touch screen. The user-friendly user interface adapts to various situations.
  • Page 12 For each AVENAR panel 2000 which needs to be networked with other panels, a premium license is required. It is not sufficient to equip only one AVENAR panel 2000 with a premium license to network multiple panels. An AVENAR panel 2000 with premium license can be networked with any AVENAR panel 8000 and with FPA-5000.
  • Page 13 AVENAR panel AVENAR panel series | en Figure 2.2: Overview of panel controller Pos. Designation Function Interfaces Panel networking and inputs for internal device monitoring Touchscreen Operating the networked system through virtual buttons and variable display windows 6 fixed buttons Standard entries...
  • Page 14 | AVENAR panel series AVENAR panel Additional annunciator modules, each with 16 red and 16 yellow LEDs are available to indicate a larger number of self-defined alarms, faults or deactivations. Smart Safety Link Smart Safety Link is the most reliable and secure interface to combine a fire detection and a voice alarm system (VAS).
  • Page 15: Remote Keypad

    AVENAR panel AVENAR panel series | en – 1 Rail connector – 4 Ethernet interfaces (1 / 2 / 3 / 4) for networking, prescribed usage: – 1 and 2 (blue): Panel network – 3 (green): Building management system, hierarchy panel, voice alarm system –...
  • Page 16 | AVENAR panel series AVENAR panel Pos. Designation Function Interfaces CAN1, CAN2, IN1/2, Rail Touchscreen Operating the networked system through virtual buttons and variable display windows 6 fixed buttons Standard entries Memory card slot Memory card reader for maintenance services...
  • Page 17: Housings For Frame Installation

    AVENAR panel AVENAR panel series | en In combination with an AVENAR panel 8000, standard or premium license, an AVENAR keypad 8000 can be used as a redundant panel controller. Only in this case the rail connector is needed. Installation Refer to the installation guide for the FPE-8000-FMR Remote keypad (F.01U.347.558) available...
  • Page 18 | AVENAR panel series AVENAR panel – FBH 0000 A Mounting Frame Large – FMH 0000 A Mounting Frame Medium – FSH 0000 A Mounting Frame Small The housings for frame installation require the following mounting frames for surface-mounted version: Housing type Mounting frames CPH 0006 A FBH 0000 A...
  • Page 19 AVENAR panel AVENAR panel series | en Housing type Panel controller UPS power Batteries supply units CPH 0006 A 2 x 45 Ah MPH 0010 A EPH 0012 A PSF 0002 A 2 x 45 Ah PMF 0004 A 4 x 45 Ah USF 0000 A Installation Kits for 48 cm (19") racks Special installation kits are available for installing the frame installation housing in 482.6 mm...
  • Page 20: Housings For Wall Mounting

    | AVENAR panel series AVENAR panel Housings for wall mounting Figure 2.4: Housings for wall mounting Wall mounting housings are screwed directly onto the wall. This reduces the installation depth by approx. 9 cm, although the smaller 12 V/28 Ah batteries must be used as a result.
  • Page 21 AVENAR panel AVENAR panel series | en The table below shows the maximum number of: – Panel controllers – UPS power supply units – Batteries Housing type Panel controller UPS power supply Batteries units HCP 0006 A 2 x 28 Ah HBC 0010 A 2 x 28 Ah...
  • Page 22: System Overview

    | AVENAR panel series AVENAR panel System overview LSN improved/classic Figure 2.5: System overview with periphery Position Description LSN loop (classic or improved version) Conventional stub with EOL resistor or EOL module (optional: conventional loop) The tables below list the various product groups with all compatible peripheral devices.
  • Page 23 AVENAR panel AVENAR panel series | en Product group Product name Interface Automatic fire Point detectors detectors FAP-425/FAH-425 LSN 0300 A FAP-520 LSN 1500 A FCP-500 CZM 0004 A FCP-320/FCH-320 FLM-420/4‑CON OOH740-A9-Ex FLM-420/4‑CON Connection with DCA1192/SB3 Wireless smoke detectors and manual call points...
  • Page 24 | AVENAR panel series AVENAR panel Product group Product name Interface Notification Audible and visual notification appliances appliances ROLP-LX LSN 0300 A LSN 1500 A FNX-425U LSN 0300 A LSN 1500 A Audible notification appliances FNM-320 LSN 0300 A...
  • Page 25: Networking

    AVENAR panel AVENAR panel series | en Product group Product name Interface Fire service FBF 100 LSN Classic LSN only: devices LSN 0300 A LSN 1500 A FAT 2002 FPE-5000-UGM + FLM-420-I2 FAT 2002 RE (+ ADP-NB*) FMF-FAT/FMF-FBF-FAT FMF-ADP-TTY FMF-FIBS FMF-ADP-TTY FMF-ESPA...
  • Page 26: Connection To A Voice Alarm System

    | AVENAR panel series AVENAR panel Figure 2.6: Connection to BIS For a multiple-building network, it is essential to clarify with the network administrator: – whether the network is designed for multiple-building connections (e.g. there must be no technical interference due to differences in grounding potential) –...
  • Page 27 AVENAR panel AVENAR panel series | en Plena RS232 ≤ 3m Figure 2.7: Connecting a Plena Voice Alarm System Bosch Sicherheitssysteme GmbH 2022-07 | 5.0 | F.01U.378.910 System manual...
  • Page 28: Planning

    (creeping short circuit and creeping open monitoring). – Conventional detectors of the Bosch portfolio for fire products can be connected using one of the following methods: – Using the CZM 0004 A 4 Zone Conventional Module The module provides four DC primary lines (zones).
  • Page 29: Detection Points

    As stipulated by EN 54-2, panels with more than 512 detectors and manual call points must be equipped with a redundant panel controller. Combined with an AVENAR panel 8000, an AVENAR keypad 8000 can be used as a redundant panel controller.
  • Page 30: Address Setting

    | Planning AVENAR panel Address setting LSN elements are addressed via rotary switches (e.g. FAP 425-O-R) or DIP switches (e.g. E/W versions of the FLM-420). For setting addresses with DIP switches, refer to the instructions in the installation guide supplied with the product.
  • Page 31: Topologies In Local Security Network

    AVENAR panel Planning | en Topologies in Local Security Network Loop topology Each LSN element provides a built-in isolator between the b1 and b2 connectors. The current flows through the LSN element between b1 and b2. With the return of the current to the LSN module the loop is formed.
  • Page 32 | Planning AVENAR panel Notice! - From LSN module software version 1.0.35 onward, you can operate LSN improved elements and LSN classic elements in combination in a loop or in a stub. - If an LSN classic element is present, only 127 elements can be used in the loop.
  • Page 33: Failure Handling In Local Security Network

    AVENAR panel Planning | en LSN 0300 A LSN 0300 A LSN 0300 A LSN 1500 A LSN 1500 A LSN 1500 A 2 stubs with Loop with branches Loop with one- branches element branches Table 3.6: Topologies in LSN improved with manual address setting (T-tap)
  • Page 34: Redundancy

    3.6.2 Remote keypad as redundant panel controller In combination with an AVENAR panel 8000, standard or premium license, an AVENAR keypad 8000 can be used as a redundant panel controller. Only in this case the rail connector is needed.
  • Page 35: Achievable Cable Length With Lsn 0300 A

    AVENAR panel Planning | en Achievable cable length with LSN 0300 A The usable cable length depends essentially on the resistance of the cable and the quantity and current consumption of the network elements. The way in which the elements are distributed locally on the bus also makes a difference.
  • Page 36 | Planning AVENAR panel Notice! Remote indicators activated by the detector C point: A maximum additional cable length of 500 m is allowed when using remote indicators (e.g. FAA-420-RI-DIN/FAA-420-RI-ROW). The total length of installed cable must not exceed the limit of 1600 m.
  • Page 37: Achievable Cable Length With Lsn 1500 A

    AVENAR panel Planning | en L [m] Figure 3.2: Diagram for determining the maximum achievable cable length: LSN improved elements with LSN 0300 A cable length in meters number of LSN improved elements 1600 m limit bus dynamic limit maximum possible number of LSN improved elements = 254 300 mA limit...
  • Page 38 | Planning AVENAR panel = bus end voltage = 15 volt (must not fall below this limit!) q = cable cross section = 0.503 mm (for cable Ø 0.8 mm) = number of elements ρ = specific resistance of copper = 0.0178 mm = FET resistance = 0.7 Ω (LSN classic) or 0.35 Ω (LSN improved), = average current consumption of elements in [A]...
  • Page 39 AVENAR panel Planning | en L [m] 3200 1,25mA 3000 2800 2600 b = 127 2400 2200 2000 1800 0,4mA 1600 1400 1200 1000 0,7mA 20mA 10mA 7,5mA 300mA 1,5mA 4,5mA 3,5mA 2,5mA 95 100 105 110 115 120 125 130 Figure 3.3: Diagram for determining the maximum achievable cable length: LSN classic elements with LSN 1500 A...
  • Page 40: Configuration With Bcm-0000-B Modules

    LSN improved elements = 254 Configuration with BCM-0000-B modules AVENAR panel 8000 can be powered by up to 8 BCM-0000-B battery controller modules, each with its own UPS 2416 A power supply unit. Current consumption is equally distributed among all battery controller modules.
  • Page 41 AVENAR panel Planning | en MAIN POWER MAIN POWER MAIN POWER MAIN POWER TROUBLE TROUBLE BATTERY 1 BATTERY 1 TROUBLE TROUBLE BATTERY 2 BATTERY 2 TROUBLE TROUBLE MAIN BAT1 BAT2 FAULT MAIN BAT1 BAT2 FAULT MAIN POWER MAIN POWER MAIN POWER...
  • Page 42 | Planning AVENAR panel EPH 0012 A 12 V / 45 Ah 12 V / 45 Ah 12 V / 45 Ah 12 V / 45 Ah 12 V / 45 Ah 12 V / 45 Ah 12 V / 45 Ah 12 V / 45 Ah Figure 3.6: Configuration of 1 to 4 BCM modules (frame installation)
  • Page 43 AVENAR panel Planning | en HBE 0012 A HBE 0012 A UPS 2416 A UPS 2416 A UPS 2416 A 12 V / 28 Ah 12 V / 28 Ah 12 V / 28 Ah 12 V / 28 Ah...
  • Page 44: Protective Earth And Equipotential Bonding

    | Planning AVENAR panel Standby Current Calculation to EN 54-4 x 0,5h Batt Batt Alarm = 6A - max, Standby max, A Standby = min max, Standby max, A Formula (1) describes the maximum system current to guarantee a particular back-up time (Imax,Standby).
  • Page 45: Installation

    The standard precautions for CMOS technology must be taken when handling PC boards. Warning! Risk of overheating Bosch provides no front door for this system. You are not allowed to operate the system with a front door. Otherwise, the system can overheat, because the air vents are blocked. –...
  • Page 46: Installation Sequence

    Building Management System – If connected to a building management system (Bosch Building Integration System BIS) via an Ethernet interface using an OPC server, the following must be noted: In a multi-building network, it is essential to clarify with the network administrator whether the network is designed for multi-building connections (e.g.
  • Page 47: Installation Of Cph 0006 A, Fully Assembled Panel

    AVENAR panel Installation | en – Optional: accessories for housing – Power supply unit and batteries – Panel rail – Panel controller – Functional modules 4 After installation Store all documents. Installation of CPH 0006 A, fully assembled panel The installation sequence is given by the numbers 1 to 9.
  • Page 48: Installation Of Hcp 0006 A, Fully Assembled Panel

    | Installation AVENAR panel Installation of HCP 0006 A, fully assembled panel The installation sequence is given by the numbers 1 to 10. BCM-0000-B PRS-0002-C PRD 0004 A <= 4 Module HCP 0006 A FPO-5000-PSB-CH 12 V / 28 Ah...
  • Page 49: Fpp-5000 External Power Supply Unit Kit 24 V/6 A

    AVENAR panel Installation | en Monitor with 4-wire end of line element: – On stub cabling, terminate the exposed end of an AUX line with an FLM-420-EOL4W – Insert an FLM-420-EOL4W as the last element of an LSN ring or of a stub –...
  • Page 50 | Installation AVENAR panel The FPP-5000-TI is connected directly to the LSN bus line and supplied with power via the bus line. You can find the installation instructions for the FPP‑5000‑TI module at www.boschsecurity.com (document number for installation instructions: F.01U.081.396).
  • Page 51: Commissioning

    Observe all country-specific testing and acceptance regulations. – A functional test must be carried out before commissioning. Bosch recommends at least one functional test and one visual inspection per year. – Follow the shut down procedure specified in the user guide, before removing the power from the panel or remote keypad.
  • Page 52: Testing The Power Supply

    | Commissioning AVENAR panel 5.1.1 Testing the power supply Measure the voltage of the batteries. The target values are12.0 V to 14.1 V, or 24 V to 28.2 V. Test the power failure function Remove the fuse and make sure that the failure of the power supply is indicated on the display.
  • Page 53 Firmware V3.x combines AVENAR panel series and FPA-5000 panel series in one panel network. This implies that when AVENAR panel and AVENAR keypad are running firmware V3.x, they only contain bound product features and peripheral devices that are also available with MPC-xxxx-B and MPC-xxxx-C panel controllers.
  • Page 54: Storing Trace Files On A Memory Card

    After restart, select the Bosch logo to verify the software version. Storing trace files on a memory card AVENAR panel has the option to store trace files on a memory card, for instance for an expert analysis when the system behaves unexpected.
  • Page 55 AVENAR panel Commissioning | en Notice! Do not remove or rename files. Bosch Sicherheitssysteme GmbH 2022-07 | 5.0 | F.01U.378.910 System manual...
  • Page 56: Maintenance And Service

    Notice! Have maintenance and inspection work carried out regularly by trained, qualified personnel. Bosch recommends a functional and visual inspection at least once a year. Warning! Live components and stripped cable! Risk of injury from electric shock. The system must be current-free during connection work.
  • Page 57: Replacement Of Fpa Panel Controller

    Exchange the short rail when the panel is equipped with a PRS 0002 A. Not exchanging the short rail will generate faults. Battery controller module – AVENAR panel cannot comply with EN 54-4 when the panel contains the legacy battery controller BCM-0000-A. – Replace all BCM-0000-A by BCM-0000-B battery controller modules.
  • Page 58 – AVENAR panel 8000 is not compatible with the CRP 0000 A cable set. Use an FPE-8000- CRP cable set instead. –...
  • Page 59 AVENAR panel Maintenance and service | en – To simplify the panel controller replacement, it is recommend not the change the Ethernet pattern. For instance keep the Ethernet switch in the panel and keep the OPC or FSI interface connected to the switch. Removing the switch or moving the OPC or FSI interface to Ethernet port 3 will result in a changed autonomy.
  • Page 60: System Limits

    | System limits AVENAR panel System limits System limits AVENAR panel 8000 Panels/remote keypads/OPC servers in the network Max. number Ethernet / CAN LSN elements Max. number Stand-alone panel 4096 Per network panel 2048 Total network 32768 Detection points Max.
  • Page 61: System Limits Avenar Panel 2000

    IOS 0232 A LSN 0300 A LSN 1500 A NZM 0002 A RMH 0002 A RML 0008 A System limits AVENAR panel 2000 Panels/remote keypads/OPC servers in the network Max. number Ethernet / CAN (premium license) LSN elements Max. number...
  • Page 62 | System limits AVENAR panel LSN elements Max. number Per network panel 1016 Total network 32512 Detection points Max. number EN 54 compliant panel Stand-alone panel, not EN54 compliant 4096 Networked panel, not EN 54 compliant 2048 Total network...
  • Page 63: Maximum Number Of Devices Per Functional Module Or Interface Module

    AVENAR panel System limits | en Configuration limits per fire panel (FSP-5000-RPS) Max. number Exportable objects including counters in the entire panel cluster 2000 (without pre-defined system counters) Importable objects including counters (without pre-defined system 2000 counters) Automatic connections to remote keypad...
  • Page 64: Power Loss Of Panel Components

    | System limits AVENAR panel Module Device Max. number Further information FMF-ADP-TTY FMF-FAT FMF-ADP-FBF FMF-FBF-FAT FLM-420-I8R1-S FCS-LHD-2EN Altogether only 200 LSN devices including max. 2 EOL modules on the same LSN bus No pre-alarm LSN 0300 A FLM-420-RLE-S Max. number is valid for fire...
  • Page 65: Fpp-5000 External Power Supply Unit Kit 24 V/6 A

    AVENAR panel System limits | en Component Power loss FPE-2000-SPC max. 10 W FPE-5000-UGM 0.17 W FPE-8000-FMR max. 12 W FPE-8000-PPC max. 10 W FPE-8000-SPC max. 10 W IOP 0008 A 0.24 W IOS 0020 A 0.36 W IOS 0232 A 0.36 W LSN 0300 A – 1.50 W (AUX with 490 mA load) –...
  • Page 66: Appendix

    | Appendix AVENAR panel Appendix Options with requirements under EN 54‑2:1997/A1:2006 The panel provides the following options with requirements under EN 54‑2:1997/A1:2006: – Output for activation of fire alarm devices – Activation of fire alarm transmission equipment – Output to fire alarm transmission equipment –...
  • Page 67 AVENAR panel Appendix | en – a– b+ – a– b+ – a– b+ – a– b+ AUX1 LSN1 AUX2 LSN2 AUX1 LSN1 AUX2 LSN2 – NO COM – NO COM REL1 REL1 Figure 8.1: Several FLM-420-RLE modules in the LSN loop Additional documentation 8.3.1...
  • Page 68 | Appendix AVENAR panel Mounting Frames Designation Installation manual ID FBH 0000 A Mounting Frame Large 4998153998 FHS 0000 A Mounting Frame Large with Distributor Rail 4998154018 FMH 0000 A Mounting Frame Medium 4998153999 FSH 0000 A Mounting Frame Small 4998154000 48 cm (19”) Installation Kits for Frame Installation Housing...
  • Page 69 AVENAR panel Appendix | en Designation Installation manual ID RLE 0000 A Junction Board F01U003090_610 Mounting Kits for Ethernet switch and media converter Designation Installation manual ID FPM-5000-KES Mounting Kit for Ethernet Switch F01U260523 FPM-5000-KMC Mounting Kit for Media Converter F01U260524 8.3.4...
  • Page 70 | Appendix AVENAR panel User manuals FPE-8000-FMR and FPE-2000-SPC | FPE-2000-PPC | FPE-8000-SPC | FPE-8000- Designation User manual ID FPE-2000-SPC panel controller, standard license F01U378877 FPE-2000-PPC panel controller, premium license F01U378877 FPE-8000-SPC panel controller, standard license F01U378877 FPE-8000-PPC panel controller, premium license...
  • Page 71 AVENAR panel Index | en Index Symbols FLM-420/4‑CON  28 “Detector FSP-5000-RPS Programming Software  8, 51 Manual”  23 Functional module  10 Functional test  51 Numerics 4 Zone Conventional Module  28 Height unit  68 Housing Address Setting  30 frame installation  17 Manual  30...
  • Page 72 | Index AVENAR panel Periphery  22 Planning  9, 28 Instructions  28 Software  9, 10, 28 Plena Voice Alarm System  26 Power loss  65, 000, 000, 000, 000, 000, 000 Power supply External  49 Praesideo  26, 60, 62 Redundancy  28, 29, 34 Keypad  34...
  • Page 73 AVENAR panel Index | Bosch Sicherheitssysteme GmbH 2022-07 | 5.0 | F.01U.378.910 System manual...
  • Page 74 | Index AVENAR panel 2022-07 | 5.0 | F.01U.378.910 Bosch Sicherheitssysteme GmbH System manual...
  • Page 76 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2022 Building solutions for a better life. 202207221041...

Table of Contents