Nussbaum POWER LIFT HL 2.30 NT Operating Manual And Inspection Book

Nussbaum POWER LIFT HL 2.30 NT Operating Manual And Inspection Book

Hide thumbs Also See for POWER LIFT HL 2.30 NT:

Advertisement

Operating Manual and Inspection Book
Including Spare Parts List
POWER LIFT HL 2.30 NT
HYMAX HL 3000 PH
POWER LIFT HL 2.35 NT
HYMAX HL 3500 PH
POWER LIFT HL 2.40 NT
HYMAX HL 4000 PH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POWER LIFT HL 2.30 NT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nussbaum POWER LIFT HL 2.30 NT

  • Page 1 Operating Manual and Inspection Book Including Spare Parts List POWER LIFT HL 2.30 NT HYMAX HL 3000 PH POWER LIFT HL 2.35 NT HYMAX HL 3500 PH POWER LIFT HL 2.40 NT HYMAX HL 4000 PH...
  • Page 3 Serial number:........Dealer address / phone Otto Nußbaum GmbH & Co.KG | Korker Str. 24 | D 77694 Kehl-Bodersweier www.nussbaum-group.de | email: info@nussbaum-group.de Service hotline Germany: 0800 5 288 911 | Service Hotline International: +49 180 5 288 911...
  • Page 4: Table Of Contents

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Contents Introduction ........................... 3 Assembly protocol ......................... 5 Transfer protocol ........................6 1 General information ......................7 1.1 Set up and test the lift ..................... 7 1.2 Hazard information ......................
  • Page 5: Introduction

    POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Introduction Nussbaum products are a result of many years of experience. A high quality standard and superior concept guarantees you reliability, long lifetimes and economical operation. To prevent unnecessary damage and hazards, read this operating manual carefully and always comply with its contents.
  • Page 6 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Organizational measures The operating manual is always to be kept ready at the location of use of the system. Supplemental to the operating manual, refer to and comply with generally valid legal and other binding regulations for accident prevention and for environmental protection.
  • Page 7: Assembly Protocol

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT After successful set up, complete this form fully, sign it, make a copy and send the original to the manufacturer within a week. The copy remains in the inspection book.
  • Page 8: Transfer Protocol

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Transfer protocol The lift..............With serial number..........was set up on (date)....... at (company name)..........in (town, city).......... checked for function and safety and put into operation.
  • Page 9: General Information

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 1 General information Technical documentation contains important information for safe operation and for retaining functional safety of the lift. • To verify lift set up, the assembly protocol form is to be completed, signed and sent to the manufacturer.
  • Page 10: Lift Master Forms

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 2 Lift master forms 2.1 Manufacturer Otto Nußbaum GmbH & Co.KG Korker Strasse 24 D-77694 Kehl-Bodersweier 2.2 Purpose The lift is a lifting tool for raising vehicles with a total weight of (* see list) in normal workshop operation at a maximum load distribution of (2:3**) (1:3***) in or against the drive-in direction A single load from only one or two lifting arms may not happen.
  • Page 11: Changes To The Design / Construction

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 2.3 Changes to the design / construction Inspections by a technical expert are required before recommissioning (Date, type of change, technical expert signature) ..............................
  • Page 12: Declaration Of Conformity

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 2.5 Declaration of conformity 20100016 OPI - 10 - Version 1.1...
  • Page 13 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 11 - Version 1.1...
  • Page 14: Technical Information

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 3 Technical information 3.1 Technical data Load carrying capacity: POWER LIFT HL 2.30 NT = 3000 kg POWER LIFT HL 2.35 NT = 3500 kg POWER LIFT HL 2.40 NT = 4000 kg...
  • Page 15: Safety Devices

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 3.2 Safety devices 1. Over-pressure valve Hydraulic system fuse against over-pressure 2. Check valve Secure the vehicle against unauthorized lowering 3. Main switch with curtain lock device Fuse to prevent unauthorized use 4.
  • Page 16: Data Sheet Power Lift Hl 2.30 Nt

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 3.3 Data sheet POWER LIFT HL 2.30 NT 20100016 OPI - 14 - Version 1.1...
  • Page 17 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 15 - Version 1.1...
  • Page 18 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 16 - Version 1.1...
  • Page 19: Data Sheet Power Lift Hl 2.35 Nt

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 3.4 Data sheet POWER LIFT HL 2.35 NT 20100016 OPI - 17 - Version 1.1...
  • Page 20 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 18 - Version 1.1...
  • Page 21 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 19 - Version 1.1...
  • Page 22: Data Sheet Power Lift Hl 2.40 Nt

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 3.5 Data sheet POWER LIFT HL 2.40 NT 20100016 OPI - 20 - Version 1.1...
  • Page 23 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 21 - Version 1.1...
  • Page 24: Hydraulic Plan

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 3.6 Hydraulic plan 0 . 9 0 . 8 0 . 7 0 . 5 0 . 4 0 . 3 0 . 2 0 .
  • Page 25 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Hydraulic parts Oil container 230HLNT01913 Suction filter 980012 Mechanical pump POWER LIFT HL 2.30 NT 3.2 cm³ 982032 Mechanical pump POWER LIFT HL 2.35 NT / HL 2.40 NT 2.7 cm³...
  • Page 26: Electrical Plan

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 3.7 Electrical plan 20100016 OPI - 24 - Version 1.1...
  • Page 27 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 25 - Version 1.1...
  • Page 28 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 26 - Version 1.1...
  • Page 29 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 27 - Version 1.1...
  • Page 30 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 28 - Version 1.1...
  • Page 31: Safety Regulations

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 4 Safety regulations When working with lifts comply with legal accident prevention regulations according to BGG 945: Comply with inspection of lifts; BGR500, operation of lifts; (VBG14).
  • Page 32: Operating Manual

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 5 Operating manual When handling the lift, it must absolutely comply with safety regulations. Carefully read the safety regulations in Section 4 before first operation! 5.1 Positioning the vehicle...
  • Page 33: Lifting The Vehicle

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Figure 3: To release the fixture plate, the rear lever must be pushed. • The lifting arm block must be ratcheted in after the fixture point has been reached.
  • Page 34: Lift Synchronization

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Figure 4: Operating unit Optional energy set Operating lever Fig. similar Lift => push the lever forwards Main switch Lower => pull the lever backwards 5.3 Lift synchronization...
  • Page 35: Behavior In Cases Of Error

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 6 Behavior in cases of error Defective operational readiness of the lift may be due to a simple error. Check the system for the listed sources of error.
  • Page 36: Emergency Discharge

    Legal principles: BSV (operating equipment regulation) + BGR500 (Operation of work equipment). Value is placed on long lifetimes and safety in the development and production of Nussbaum products. To guarantee the safety of the operator, product reliability, low running costs, keep the warranty and also the long-lifetime of the product, proper set up and operation is just as important as regular maintenance and sufficient care.
  • Page 37: Maintenance Plan

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 7.1 Maintenance plan Before beginning service, disconnect from power. The work area around the lift is to be secured against unauthorized use.
  • Page 38 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Version with MINI-MAX lifting arm 1. Blow out and spray bolts. Check the rollers for wear. 2. Check the locking screws (this is only screwed in lightly and is then glued (Loctite)).
  • Page 39 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Check electrical components for function and condition. Plug At least 1 x per year Operating lever with button switch Daily During assembly and maintenance always check the condition of electrical lines.
  • Page 40 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Excerpt from BGR237 Specifications for the hydraulic hose lines Recommended exchange intervals Normal specification: 6 years (operation duration including max. 2 years storage Increased demands e.g.
  • Page 41: Cleaning The Lift

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 7.2 Cleaning the lift A regular and expert clean helps retain the value of the lift. Additionally, it can also be a pre-requisite for the preservation of guarantee claims for any eventual corrosion damage.
  • Page 42: Assembly And Commissioning

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 8 Assembly and commissioning Figure 20: 8.1 Set up guidelines • Lift set up is done by trained manufacturer personnel or a contract partner. Set up is to be done according to the assembly instructions.
  • Page 43 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Cross-beam Riser Riser Counter column Operating column Short lifting arm Short lifting arm Operating unit Figure 21: General assembly view without riser extension A foundation must be made according to the "Foundation plan"...
  • Page 44: Lift Assembly With Riser Extension

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT • Position and align the lift and lift columns using a bubble level. • The base plates are also to be supported with suitable underlays (thin metal strips) to ensure precise vertical set up and contact between the base plate and the floor.
  • Page 45 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Riser extension is set on the existing riser. The open side faces inwards. Set to the desired height (from 100 mm to 900 mm in 100 mm steps) depending on the ceiling height.
  • Page 46: Retrofitting The Riser Extension

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 8.1.3 Retrofitting the riser extension Extension Extension The optional riser extensions are delivered in a box. Have other supplied parts at hand.
  • Page 47 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Riser extension is set on the existing riser. The open side faces inwards. Set to the desired height (from 100 mm to 900 mm in 100 mm steps) depending on the ceiling height.
  • Page 48 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Remove existing hydraulic lines. Do not remove colour markings. Loosen and turn the T-piece and bracket visible in the figure. Exchange the supplied hydraulic hoses Place yellow and white on the top of the operating column.
  • Page 49: First Filling

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Connect blue to K1 of the operating column. Cut the cover panel to length and mount. 8.1.4 First filling When filling the hydraulic system, identify already filled cylinders (with the sticker "first filling"...
  • Page 50 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Operating lever 10 2x Allen key operating lever 11 Oil filling opening • Loosen and remove the plastic part of the operating lever (9) of both Allen screws (10) •...
  • Page 51: Lifting Arm Assembly

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT First filling without sticker. • Required oil volume: 13 litre (HLP 32) for the aggregate, hoses and cylinders. • After setting up the electrical connection to the lift, the hydraulic system can be filled.
  • Page 52: Lifting Arm Alignment

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 8.3 Lifting arm alignment • After assembly of the lift, the lifting arm may be placed at the lowest position and become difficult to move.
  • Page 53: Commissioning

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 8.4 Commissioning Before commissioning, a single safety inspection must be done (use the "single safety inspection" form). If the lift set up is done by a specialist (factory trained assembler) then he can also do the safety inspection.
  • Page 54: Safety Inspection

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 9 Safety inspection The safety inspection is required to guarantee operational safety of the lift. It is to be done: 1. Before first commissioning after setting up the lift.
  • Page 55 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Cement quality min. C20/25 Normal reinforcement Rights reserved to make changes! POWER LIFT HL 2.30 NT Hilti injection anchor POWER LIFT HL 2.35 NT POWER LIFT HL 2.40 NT...
  • Page 56 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Marking the anchoring depth Rights reserved to make changes! POWER LIFT HL 2.30 NT fischer anchor POWER LIFT HL 2.35 NT POWER LIFT HL 2.40 NT...
  • Page 57: Single Safety Inspection Before Commissioning

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Single safety inspection before commissioning Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 58: Regular Safety Inspection And Maintenance

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Regular safety inspection and maintenance Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 59 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Regular safety inspection and maintenance Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 60 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Regular safety inspection and maintenance Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 61 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Regular safety inspection and maintenance Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 62 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Regular safety inspection and maintenance Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 63 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Regular safety inspection and maintenance Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 64 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Regular safety inspection and maintenance Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 65 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Regular safety inspection and maintenance Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 66 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Regular safety inspection and maintenance Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 67 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Regular safety inspection and maintenance Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 68 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Regular safety inspection and maintenance Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ............
  • Page 69: Exceptional Safety Inspection

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Exceptional safety inspection Serial number: Complete and leave in the inspection book ____________________________ Defective Retest Test step Missing Remarks -------------------------------------------------------------------------------------------------------- -------------------------------- Model plate ...............
  • Page 70: Spare Parts List | Ersatzteilliste

    Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 10 Spare parts list | Ersatzteilliste Spare parts list Ersatzteilliste 20100016 OPI - 68 - Version 1.1...
  • Page 71 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 69 - Version 1.1...
  • Page 72 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 70 - Version 1.1...
  • Page 73 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 71 - Version 1.1...
  • Page 74 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 72 - Version 1.1...
  • Page 75 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 73 - Version 1.1...
  • Page 76 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 74 - Version 1.1...
  • Page 77 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 75 - Version 1.1...
  • Page 78 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Gültig bis 04-2013 (SN: 380973) Valid until 04-2013 Abdeckung vorbereitet für Energieset gültig bis SN:380973 230HLNT01406 Sicherung 1A Fuse 990286 Hauptschalter Main switch 990403 Motorschütz...
  • Page 79 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Hebel komplett Hydraulikblock kpl. Handle complete 230SLNT41150 230HLNT01560 Zahnradpumpe HL 2.30 NT - 982361 HL 2.40 NT - 980340 Motor 992658 Motorhalter...
  • Page 80 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Ölbehälter gültig bis 04-2013 / Oil tank valid until 04-2013 Bestellnummer kpl. 240SLH01013 Ölbehälter gültig ab 04-2013 / Oil tank valid since 04-2013 Bestellnummer kpl.
  • Page 81 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Handgriff Handgriff Handle Handle 230HLNT01411 230HLNT01408 Hebel komplett Handle complete 230HLNT01560 Hydraulikblock komplett Hydraulic block complete 230SLNT41150 Deckel Cover Ölpeilstab 230SLNT01412 Oil level gauge...
  • Page 82 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Gültig ab 04-2013 Valid since 04-2013 Frontplatte gültig ab SN:380974 230HLNT01858 Haltegriff handle 230HLNT01704 Motorschütz Hauptschalter Up contactor Main switch 990841 990403...
  • Page 83 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Haube ohne integriertem Energieset gültig ab SN:380974 230HLNT01416 cover without integrated energy set Haube mit Verriegelung 230HLNT01407-1 cover with locking equipment 20100016 OPI - 81 - Version 1.1...
  • Page 84 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 82 - Version 1.1...
  • Page 85 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT HL 2.30 NT Standard Tragarmsatz / standard arms 20100016 OPI - 83 - Version 1.1...
  • Page 86 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT HL 2.30 NT 2-fach Tragarmsatz (MB/BMW-Version) 20100016 OPI - 84 - Version 1.1...
  • Page 87 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT HL 2.30 NT Mini-Max 20100016 OPI - 85 - Version 1.1...
  • Page 88 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 86 - Version 1.1...
  • Page 89 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 87 - Version 1.1...
  • Page 90 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT HL 2.40 NT Standard Tragarme 20100016 OPI - 88 - Version 1.1...
  • Page 91 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT HL 2.40 NT Mini-Max Tragarme 20100016 OPI - 89 - Version 1.1...
  • Page 92 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Energieset komplett / Energy set complete Energieset / Energy set Schweiz/ Switzerland 225SL05091CH (Bedienseite) 225SL05092CH (Gegenseite) Energieset / Energy set 225SL05092MB Energieset / Energy set 225SL05091MB mit Betriebsstundenzähler / with elapsed time indicator...
  • Page 93 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT Verlängerung / Extension Steigrohr Steigrohr Verlängerung komplett Satz = 2 Steigrohre + Hydraulikschlauchpaket Extension complete Set = 2 extension pipes+ Hydraulic hose package...
  • Page 94 Notes:...
  • Page 95 Operating Manual and Inspection Book POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT 20100016 OPI - 2 - Version 1.1...
  • Page 96 Otto Nußbaum GmbH & Co.KG | Korker Str. 24 | D 77694 Kehl-Bodersweier www.nussbaum-group.de | e-Mail: info@nussbaum-group.de Service Hotline Germany: 0800 5 288 911 Service Hotline International: +49 180 15 288 911 20100016 POWER LIFT HL 2.30 -2.35 -2.40 NT - HYMAX HL 3000-3500-4000 PH OPI+ETL | EN | Version 1.0...

Table of Contents