Summary of Contents for Nussbaum ATT COMBI LIFT 4.40 S
Page 1
Betriebsanleitung | Prüfbuch mit Ersatzteilliste Operating manual | Inspection book including spare parts list COMBI LIFT 4.40 S HYMAX II 4000 S COMBI LIFT 4.40 S A HYMAX II 4000 S A COMBI LIFT 4.40 S PLUS HYMAX II 4000 S PLUS COMBI LIFT 4.40 S PLUS AMS HYMAX II 4000 S PLUS AMS Serien Nr.:...
Page 2
ist eine Marke der Otto Nußbaum GmbH & Co. KG is a brand of Otto Nußbaum GmbH & Co. KG OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
DEUTSCH Einleitung ___________________________________________5 Radfreiheber ________________________________ 98 AufstelIungsprotokolI _________________________________6 Anheben aus der Sicherheitsklinke ____________ 98 Übergabeprotokoll __________________________________7 Senken des Fahrzeuges ______________________ 98 RFH Schienenhöhenausgleich ________________ 99 Allgemeine Information ___________________ 8 5.10 Sicherheitsschalter unter der Fahrschiene _____ 99 Aufstellung und Prüfung der Anlage ____________8 Verhalten im Störungsfall _________________ 99 Gefährdungshinweise __________________________8 Auffahren auf ein Hindernis __________________ 100...
Page 4
Maintenance and care of the system ____ 217 Selecting the anchors _______________________ 220 System maintenance plan __________________ 217 Assembly ___________________________________ 220 Daily, as required or visible damage _________ 217 Set up and anchoring the lift ________________ 220 Maintenance 1 x per year ___________________ 217 Electrical connections ______________________ 221 Maintenance every 2 years _________________ 218 Loose/broken cable switch __________________ 221...
DEUTSCH Original Einleitung Organisatorische Maßnahmen Nußbaum Produkte sind ein Ergebnis langjähriger • Die Bedienungsanleitung ist ständig am Einsatzort Erfahrung. Der hohe Qualitätsanspruch und das der Anlage griffbereit aufzubewahren. überlegene Konzept garantieren Ihnen Zuverlässig- • Ergänzend zur Betriebsanleitung sind allgemein- keit, eine lange Lebensdauer und den wirtschaftli- gültige gesetzliche und sonstige verbindliche Re- chen Betrieb.
AufstelIungsprotokolI Nach erfolgter Aufstellung, dieses Blatt komplett ausfüllen, unterschreiben, kopieren und das Original innerhalb einer Woche an den Hersteller senden. Otto Nußbaum GmbH & Co.KG Korker Straße 24 D-77694 Kehl-Bodersweier Die Anlage mit der Seriennummer _________________________ wurde am __________________________ bei der Firma _____________________________________________ in __________________________________ aufgestellt, auf Funktion und Sicherheit überprüft und in Betrieb genommen.
Übergabeprotokoll Die Anlage ______________________________________________ mit der Seriennummer ____________________________________ wurde am __________________________ bei der Firma _____________________________________________ in __________________________________ aufgestellt, auf Funktion und Sicherheit überprüft und in Betrieb genommen. Nachfolgend aufgeführte Personen (Bediener) wurden nach Aufstellung der Hebebühne durch einen ge- schulten Monteur des Herstellers oder eines Vertragshändlers (Sachkundiger) in die Handhabung des Hub- gerätes eingewiesen.
Allgemeine Information Die Technische Dokumentation enthält wichtige In- formationen zum sicheren Betrieb und zur Erhaltung der Funktionssicherheit der Anlage. • Zum Nachweis der Aufstellung der Anlage ist das Formular Aufstellungsprotokoll unterzeichnet an den Hersteller zu senden. • Zum Nachweis der einmaligen, regelmäßigen und außerordentlichen Sicherheitsüberprüfungen ent- hält dieses Prüfbuch Formulare.
Stammblatt der Anlage Hersteller Otto Nußbaum GmbH & Co.KG Korker Straße 24 D-77694 Kehl-Bodersweier Verwendungszweck Die Hebebühne ist ein Hebewerkzeug für das Anheben von Kraftfahrzeugen bis zu einem Gesamtgewicht von 4.500 kg bei einer maximalen Lastverteilung von 2:1 in Auffahrrichtung oder entgegen der Auffahrrich- tung.
Konformitätserklärungen 2.5.1 COMBI LIFT 4.40 S, 4.40 S A, 4.40 S PLUS, 4.40 S PLUS AMS OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Page 11
2.5.2 HYMAX II 4000 S, 4000 S A, 4000 S PLUS, 4000 S PLUS AMS OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Technische Information Sicherheitseinrichtungen • Totmann Steuerung Technische Daten Beim Loslassen eines Tasters stoppt die Bewegung der Hebebühne. Tragfähigkeit Anlage • Wendeschalter mit Vorhängeschlosseinrichtung ohne Radfreiheber 4.500 kg Sicherung gegen unbefugte Benutzung. mit Radfreiheber (opti- • Überdruckventil onal) 4.000 kg Sicherung des Hydrauliksystemes gegen Über- druck.
Elektroschaltplan Sicherheitsprüfung und Schutzmaßnahmen Der Schaltschrank wurde unter Beachtung der an- Erdung nach örtlichen Vorschriften erkannten Regeln der Technik nach VDE0100/0113 Vor Inbetriebnahme prüfen, ob Motornennstrom sowie der Unfallverhütungsvorschrift VBG4 (elek- mit Motorschutzrelais übereinstimmt. Alle Klemm- trische Anlagen und Betriebsmittel) gefertigt bzw. stellen auf ordnungsgemäße Verbindung und alle errichtet und geprüft.
Page 21
3.6.1 3 x 230 V OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Page 22
OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Page 23
OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Page 24
OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Sicherheitsbestimmungen • Die Aufstellung der serienmäßigen Hebebühne in explosionsgefährdeten Betriebsstätten und Beim Umgang mit Anlagen sind die gesetzlichen feuchten Räumen (z. B. Waschhallen) ist verbo- Unfallverhütungsvorschriften nach BGG 945: Prü- ten. fung von Hebebühnen; BGR 500 Betreiben von An- • Wir weisen in unseren Plänen auf die Mindestan- lagen;...
Bedienungsanleitung Positionierung des Fahrzeuges • Die Hebebühne muss vor dem Auffahren des Fahr- zeuges vollständig abgesenkt sein und darf nur in Während der Handhabung der Anla- der dafür vorgesehenen Richtung erfolgen. ge sind die Sicherheitsbestimmungen • Das Fahrzeug auf die Fahrschienen in Längs- und unbedingt einzuhalten.
Absetzen in die Sicherheitsklinke • Fahrzeug anheben bis Räder frei sind; Taster „HE- • Durch Drücken des Tasters „Absetzen in Klinke“ BEN” (12) drücken, anschließend den sicheren (15) wird die Hebebühne in die nächst mögliche Sitz des Fahrzeuges auf der Hebebühne überprü- Klinke abgesetzt.
RFH Schienenhöhenausgleich Problem: Hebebühne lässt sich nicht anheben Bei längerem Dauerbetrieb des Radfreihebers ohne mögliche Ursachen: Abhilfe: Erreichen der untersten Position, kann es funktions- bedingt zu einem Ungleichlauf der Auffahrschienen keine Stromversorgung Prüfen der Stromversor- kommen. Im Normalfall stellt sich die Höhengleich- gung heit nach längerer Wartezeit (Abkühlen des Öles) wieder ein.
Problem: Hebebühne lässt sich nicht absenken Stromausfall kann Notablass vorgenommen werden, wenn Sicher- mögliche Ursachen: Abhilfe: heitsklinken (24) nicht eingerastet sind. Daher sollte das Ende des Stromausfalles abge- Hebebühne sitzt auf Hebebühne anheben wartet werden. Bei Ventildefekt kann die einge- Hindernis auf und Hindernis entfernen.
Page 101
19 Aufschraubkappe mit Flügelschraube 20 Ventil MV4 18 Aufschraubkappe mit Innensechskantschraube 21 Ventil MV1 Diesen Vorgang an beiden Seiten vornehmen 22 Ventil MV2 um eine gleichmäßige Absenkung des Fahr- 23 3er Innensechskantschlüssel zeuges zu erreichen. 6.2.3 Hebebühne ohne Radfreiheber Wenn die beiden Radfreiheber Ventile MV4 und Bevor die Hebebühne über den Notablass abge- MV5 durch die Flügelschrauben (19) geöffnet wur- senkt werden kann, müssen die Sicherheitsklinken...
Wartung und Pflege der Anlage Vor einer Wartung sind alle Vorberei- tungen zu treffen, dass bei Wartungs- und Reparaturarbeiten an der Huban- lage keine Gefahr für Leib und Leben und Beschädigungen von Gegenstän- den bestehen. Bei Entwicklung und Produktion von Nußbaum Pro- dukten wird auf Langlebigkeit und Sicherheit Wert gelegt.
Page 103
7.1.1 Täglich, bei Bedarf oder sichtbarer Be- Hydraulikleitungen sind dabei unbedingt auf schädigung mögliche Quetschstellen zu prüfen. Diese betrof- fenen Leitungen müssen ausgetauscht werden. • Zustand des Typenschildes, Tragfähigkeitsanga- Ansonsten sind Druckschläuche nach Bedarf, je- ben und Aufkleber prüfen. Bei Beschädigungen doch spätestens nach 6 Jahren auszutauschen.
7.1.3 Wartung alle 2 Jahre Je länger Straßenstaub, Streusalz und andere ag- Das Hydrauliköl sollte nach Herstellerangaben im gressive Ablagerungen auf der Hebebühne haften normalen Betrieb mindestens alle zwei Jahre ge- bleiben desto schädlicher ist ihre Wirkung. wechselt werden. Verschiedenste Umgebungsein- Wie oft die Anlage gereinigt werden soll hängt un- flüsse z. B. Standort, Temperaturschwankungen, in- ter anderem von der Häufigkeit der Benutzung, von...
• Für elektrischen Standardanschluss • Querträger lösen und entfernen bauseits 3 ~/N + PE, 400 V, 50 Hz bereitzustellen. • Hebebühne an den neuen Aufstellungsort trans- Die Zuleitung ist gemäß VDE 0100 mit 16 Ampere portieren träge abzusichern. Der Mindestleiterquerschnitt •...
Page 106
Vor dem Aufstellen der Hebebühne ist ein ausrei- • Die Säulen an den Enden der Querträger positio- chendes Fundament durch den Betreiber nach- nieren. zuweisen oder zu erstellen. Hierzu ist ein normal • Seile durch die Enden der Querträger ziehen und bewehrter Betonboden mit einer Güte von min.
Elektrischer Anschluss Fahrbahnniveau auf Ebenheit zueinander über- • Für den elektrischen Anschluss (siehe auch Kapitel prüfen. 15 Elektroschaltplan) ist bauseits 3~/N + PE, 400 V, • Die Auffahrschienen durch Verstellen der Befe- 50 Hz, Absicherung 16 Ampere träge bereitzustel- stigungsschrauben der Klinkenleisten (9) auf der len.
Sicherheitsüberprüfung Die Sicherheitsüberprüfung ist zur Gewährleistung der Betriebssicherheit der Hubanlage erforderlich. Sie ist durchzuführen: 1. Vor der ersten Inbetriebnahme nach dem Auf- stellen der Hubanlage Verwenden Sie das Formblatt „Einmalige Sicher- heitsüberprüfung“ 2. Nach der ersten Inbetriebnahme regelmäßig in Abständen von längstens einem Jahr Verwenden Sie das Formblatt „Regelmäßige Si- cherheitsüberprüfung“...
Introduction and comply with generally valid legal and other binding regulations for accident prevention and Nussbaum products are a result of many years of for environmental protection. experience. A high quality standard and superior • Check occasionally that personnel have an awa-...
Set up protocol After successful set up, complete this form fully, sign it, make a copy and send to the manufacturer within a week. Otto Nußbaum GmbH & Co.KG Korker Straße 24 D-77694 Kehl-Bodersweier The system with serial number ____________________________ was set up on (date) ______________________ at (company name) _____________________________________ in (town, city) _____________________________ checked for function and safety and put into operation...
Transfer protocol The system with serial number ____________________________ was set up on (date) ______________________ at (company name) _____________________________________ in (town, city) _____________________________ checked for function and safety and put into operation. The following listed people (operators) were trained to handle the lift after it was set up by a trained assem- bler of the manufacturer or a contract partner (specialist).
General information Technical documentation contains important infor- mation for safe operation and for retaining functio- nal safety of the system. • To verify system set up, the set up protocol form is to be signed and sent to the manufacturer. •...
System master sheet Manufacturer Otto Nußbaum GmbH & Co.KG Korker Straße 24 D-77694 Kehl-Bodersweier Purpose The lift is a lifting tool for raising vehicles up to a total weight or 4,500 kg, for a maximum lift distribution of 2:1 in the drive-in or against the drive-in direction. If the lift is fitted with a wheel free lift the load carrying capacity is 4,000 kg. The wheel free lift is a lifting tool for raising vehicles up to a total weight or 3,000 kg, for a maximum lift dis- tribution of 2:1 in the drive-in or against the drive-in direction.
Declaration of conformity 2.5.1 COMBI LIFT 4.40 S, 4.40 S A, 4.40 S PLUS, 4.40 G PLUS AMS OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Page 127
2.5.2 HYMAX II 4000 S, 4000 S A, 4000 S PLUS, 4000 S PLUS AMS OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Technical information Safety devices • Deadman controls Technical data Lift movement stops when a button is released. • Reversing switch with curtain lock device System load capacity Fuse to prevent unauthorized use. without wheel free lift 4,500 kg • Over-pressure valve with wheel free lift (op- Hydraulic system fuse against over-pressure.
Electrical circuit diagram Safety inspection and safety measures The control cabinet has been produced, set up Grounding according to local regulations and inspected according to recognized technolo- Before commissioning check whether the nominal gy rules according to VDE0100/0113 and accident motor current matches the motor protection relay.
Page 137
3.6.1 3 x 230 V OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Page 138
OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Page 139
OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Page 140
OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Safety regulations Operating manual When working with systems comply with legal acci- When handling the system, it must ab- dent prevention regulations according to BGG 945: solutely comply with safety regulati- inspection of lifts; BGR 500 operation of systems; ons. Carefully read the safety regulati- VBG 14.
Positioning the vehicle Set down into the safety ratchets • The lift must be completely lowered before the • Pushing the “Lower into catches” button (15) vehicle is driven on, and it may only be done in sets the lift down into the next possible catches. the intended direction.
5.10 Safety switch below the drive rails • Continue to push the “LOWER” button until the vehicle reaches the desired working height or un- The lift has a safety switch (4) fitted below the drive- til reaching the lowest position. in rails used to monitor the cables. This triggers if, •...
Problem: Motor starts, load is not lifted is possible to open the control valve (22) manually and bring the lift in the lowest position so that the Possible causes: Remedy: vehicle can be driven from the lift. An emergency lowering is an enga- The vehicle is too heavy Unload vehicle if possible gement into the system controls and may only be done by experienced...
Page 216
Only operate the lift if it is in seamless condition If you are underneath the rail, looking in drive-in di- from a safety point of view. rection, the valve to lower the wheel free lift is posi- tioned on the right side of the cylinder (see picture 024) close to the opening of the wheel free lift.
Value is placed on long lifetimes and safety in the development and production of Nussbaum pro- ducts. To guarantee the safety of the operator, pro- duct reliability, low running costs, keep the warran- ty and also the long-lifetime of the product, proper set up and operation is just as important as regular maintenance and sufficient care.
ticular, the buttons and the safety ratchet. The condition is done in adjusted, shortened time fra- components are to be exchanged if there are mes, if required and by competent personnel. defects or damage. If ther is an extension of the replacement interval, •...
tal protection office or commercial regulatory of- • Dry the system with a cloth and spray it with a fice has the obligation to disclose about disposal spray wax or oil. points). • Moving parts (bolts, bearing zones) are to be lu- bricated or oiled according to instructions.
Assembly After commissioning, the set up protocol must be completed and sent to the manufacturer. Follow the instructions enclosed in the anchor Changing the assembly location packaging. To change the assembly location the pre-conditions must be met according to the assembly guidelines. The location change is to be done according to the following sequence: •...
Each anchor must be able to be tigh- The following preparation and work steps are to be tened to the torque specified by the done: manufacturer. Safe operation of the lift • To achieve a greater degree of protection is not guaranteed with a lower torque. against humidity from the workshop floor, a thin PE foil should be placed between the workshop floor and column base plate (3) before anchors...
Safety inspection important to set up and level the lift platform as precisely as possible. For this, the following work steps must be done: The safety inspection is required to guarantee ope- rational safety of the lift. It is to be done: •...
Single safety inspection before commissioning Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................
Regular safety inspection and maintenance Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................
Page 225
Regular safety inspection and maintenance Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................
Page 226
Regular safety inspection and maintenance Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................
Page 227
Regular safety inspection and maintenance Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................
Page 228
Regular safety inspection and maintenance Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................
Page 229
Regular safety inspection and maintenance Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................
Page 230
Regular safety inspection and maintenance Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................
Page 231
Regular safety inspection and maintenance Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................
Page 232
Regular safety inspection and maintenance Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................
Page 233
Regular safety inspection and maintenance Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................
Exceptional safety inspection Copy, complete and leave in the inspection book Serial number: _______________________________ Test step Defective Post- Remarks or missing inspection □ □ □ Model plate .................._______________________________ □ □ □ Operating manual ................_______________________________ □...
Page 237
Ersatzteilliste Spare parts list HYMAX II 4000 S COMBI LIFT 4.40 S COMBI LIFT 4.40 S A HYMAX II 4000 S A HYMAX II 4000 S PLUS COMBI LIFT 4.40 S PLUS COMBI LIFT 4.40 S PLUS AMS HYMAX II 4000 S PLUS AMS Made Germany...
Page 238
COMBI LIFT 4.40 S - HYMAX II 4000 S 10.xx Hub 1816 mm, Tragfähigkeit 4.500 kg Stroke 1816 mm, load capacity 4.500 kg 12.01.2016 BeMe 440CL00021 440CL08800 ANTRIEBSSCHIENE 9125M06ZN SCHEIBE 440CL08590 AUFFAHRRAMPE KOMPLETT 97991-M12X30 SENKSCHRAUBE 440CL05300 HUBSÄULE 9912-M12X35 ZYLINDERSCHRAUBE 440CL05200 HUBSÄULE LINKS VORNE 440CL08137 PVC-SCHUTZSCHLAUCH...
Page 239
COMBI LIFT 4.40 S AMS - HYMAX II 4000 S AMS 11.xx mit Achsmessset | With axis measurement set mit Achsmessset + Achsmessklinke Hub 1816 mm, Tragfähigkeit 4.500 kg With axis measurement set + axis measurement catch Stroke 1816 mm, Load capacity 4500 kg 11.01.16 BeMe 440CL00022 440CL09700 AMS KOMPLETT (MIT FLATPLATE)
Page 240
COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS 12.xx mit Radfreiheber und Achsmessset | With wheel free lift and axis measurement set mit Radfreiheber + Achsmessset + Achsmessklinke Hub 1816 mm, Tragfähigkeit 4.000 kg With wheel free lift + axis measurement set + axis measure- ment catch Stroke 1816 mm, load capacity 4.000 kg 13.01.16 BeMe 440CL00024...
Page 241
OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN...
Page 242
Achsmessset bei | Axis measurement set COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS 15.xx 0.300 08.08.2016 BeMe 440CL09600 440CL08451 AUFSETZKASTEN 260 X 514 X 50 9915_1-A8_4 SCHEIBE 440CL08501 AUFSETZKASTEN 500 X 514 X 50 9912-M8X10 ZYLINDERSCHRAUBE DIN 912 440CL58545...
Page 243
Achsmessset bei | Axis measurement set COMBI LIFT 4.40 S AMS - HYMAX II 4000 S AMS 16.xx 0.300 08.08.16 BeMe 440CL09700 440CL08451 AUFSETZKASTEN 260 X 514 X 50 440CL08294 RECHTECKROHR 440CL08501 AUFSETZKASTEN 500 X 514 X 50 9915_1-A8_4 SCHEIBE 440CL08461 FLAT-PLATE 514 X 1610 9912-M8X10...
Page 244
Antriebsschiene bei | Drive rail COMBI LIFT 4.40 S PLUS - HYMAX II 4000 S PLUS 20.xx 08.08.16 BeMe 440CL08600 440CL08603 ANTRIEBSSCHIENE SCHWEISSTEIL 440CL08121 BOLZEN 99-330-16-00-5L BLOCK KOMPLETT 435H04008 DISTANZ 030RFH00020 RADFREIHEBER NTPLUS 435H04011 DISTANZ 030ULN03302 STABLAMPE KOMPLETT 440CL08139 HALTER 440CL02100 ZYLINDER KOMPLETT 9951970...
Page 260
Händleradresse/Telefon: Dealer address/phone: Otto Nußbaum GmbH & Co. KG • Korker Str. 24 • D-77694 Kehl-Bodersweier www.nussbaum-group.de • E-Mail: info@nussbaum-group.de Service Hotline Germany: 0800-5 288 911 Service Hotline International: +49 180-5 288 911 OPI_COMBI LIFT 4.40 S PLUS AMS - HYMAX II 4000 S PLUS AMS_V1.0_DE-EN_112017...
Need help?
Do you have a question about the ATT COMBI LIFT 4.40 S and is the answer not in the manual?
Questions and answers