Palmgren 9683338 Operating Instructions & Parts Manual page 7

14.5” vertical column cold saw
Table of Contents

Advertisement

Electrical Connection To The Mains
NOTE: Install a differential thermomagnetic switch with
characteristics suited to the mains.
Before machine activation check motor
for correct voltage wiring.
Make sure that the power supply voltage corresponds to the
voltage on the motor plate. Connect the cable to the power
supply line observing the color codes of the individual wires, pay
particular attention to the earth wire. Ensure that the rotation of
the circular blade is in the direction shown by the arrow on the
guard before first use.
Assembly: Handle
See "Maintenance/Repair" on page 14 for all part numbers
shown in the procedure steps.
1.
Connect the electric cable terminals 220 to the microswitch
218 and place it inside the handle.
Figure 3. Microswitch Installation
2.
Fit the supplied head lever 36, into position and fasten it by
means of the nut 47.
3.
Fasten the cover using the screws 221 and then by
fastening the handle to the lever using the screw 219. Make
sure that the cable is inserted into the lever slot, after having
checked that there are no burrs or sharp edges in the slot
Figure 4. Handle
36
47 (on lower
end)
Length Stop
4.
Slide the two rods into the bracket. Then fit the assembled
rod into the matching hole on the right side of the vise
platform.
81
Figure 5.
Length Stop
Roller Stand
1.
Using the provided screws, attach the stand legs to the roller
frames.
Figure 6. Roller Stand
2.
Attach the whole assembly to the frame of the saw.
3.
Fit the rollers into the roller frame.
4.
Adjust the tilt/height of the roller stand by screwing/
unscrewing the feet of the roller stand. Employ a level to
assist if needed.
Saw Blade
Select the appropriate blade for the job as shown in "Blade
Selection" on page 11.
1.
Remove guard 121 exposing saw shaft and saw collars.
78
80
83
7

Advertisement