Semi-automatic mode cutting operation:
NOTE: Pushing the emergency stop button removes power from
the blade motor. Releasing it,
microswitch in the handle.
1.
Select a suitable blade as outlined in "Blade Selection" on
page 11.
2.
Connect the machine to the central pneumatic system and
position the manometer on 6-7 atm.
3.
Adjust the head vertical stops so that the downward stroke
does not allow the blade to contact the bed. Verify the
head's downward stroke stop adjustment by performing an
idle cycle.
4.
Adjust the cut angle by raising the working head to
maximum height, loosening the fastening handle 82 (see
"Parts List" on page 15) and turning the rotating plate 51
to the required angle, fasten the plate securely when angle
is set.
5.
To make a series of cuts of the same length, set the bar-stop
78 at the required distance from the blade. Secure it with the
knob.
6.
Clamp the piece to be cut with handwheel 77.
10
pulling it out, connects power to the

CHANGING BLADES

To remove and replace the saw blade:
1.
Make sure the cold saw is disconnected from the power.
2.
Hold the saw blade still, by lowering the blade into a piece of
wood set in the vise.
3.
Unhook the guard rod (A) from the guard.
A
B
C
Figure 9.
Blade Hardware
4.
Remove disk fastening screw (B).
5.
Remove the disk fastening flange (C).
6.
Use gloves to safely remove the saw blade.
7.
Follow these steps in the reverse order to install a new
blade.
NOTE: The new blade will need to be broken in before full use.
See "Blade not worn-in correctly" in "Troubleshooting Guide" on
page 12.