Activating generation of the technology system data

Procedure
Step
Activity
1
Double-click "Technology" on the mounting rail.
2
Select the "Technology system data" tab, then set the "Generate technology system data" check box.
Confirm with "OK".
Result: When you download these data to the target system later on in this Getting Started, the system also
generates the technology system data and includes these in the download to your CPU 317T-3PN/DP.
Note: If you do not set the check box, the technology system data is not generated and the technology data
that is present on the CPU is deleted at the next download.
CPU 317T-3PN/DP: Controlling a SINAMICS S120
Getting Started, 10/2013, A5E00480391-06
4.1 Creating a T station
Result
The "Properties - Technology" dialog box