Configuration
4.3 Configuring a SINAMICS drive in S7T Config
Step
Activity
6
In the "SINAMICS_S120 – Message frame configuration" dialog box check whether the message frame type has
been set to "SIEMENS message frame 105" for both drives and then click "Align message frame with HW Config:
Set up addresses" to have the message frame address set in the "Input data" and "Output data" columns.
7
Check whether valid addresses are entered for all telegrams and close the dialog box.
8
Select the Project > Save and Compile Changes menu command to save and compile the entire technology
project.
9
Select the Project > Connect to target system menu command to switch to online mode.
54
CPU 317T-3PN/DP: Controlling a SINAMICS S120
Getting Started, 10/2013, A5E00480391-06