Step
Activity
14
Close the output window with File > Close.
15
Close the NetPro configuration program by calling the Network > Exit command.
16
Finalize your HW configuration by calling the Station > Save
and compile command.
4.1.2

Creating a T station without station wizard

4.1.2.1

Configuring CPU 317T-3PN/DP in HW Config

Procedure
Step
Activity
1
Create a new project in the SIMATIC Manager (for example,
"GS_317T_3PN-DP_with_S120") and add a SIMATIC 300 station.
2
Open HW Config by selecting the "SIMATIC 300" station and
double-clicking "Hardware".
3
From the hardware catalog, select the "SIMATIC Technology CPU"
profile.
4
Open the folder "SIMATIC 300 > RACK-300" and insert a mounting
rail in the station window of HW Config with drag-and-drop.
5
Drag-and-drop the "PS 307 10A" power supply module onto the
mounting rail.
CPU 317T-3PN/DP: Controlling a SINAMICS S120
Getting Started, 10/2013, A5E00480391-06
4.1 Creating a T station
Result
The system compiles your project, and adds
the "Technology Objects" object to the
project window in SIMATIC Manager.
Result
The SIMATIC 300 station is
displayed in SIMATIC Manager.
HW Config opens.
The "SIMATIC Technology"
directory is displayed.
This creates a mounting rail.
The power supply module appears
on the mounting rail.
Configuration
25