Analog Devices ADRV9029 User Manual page 25

Transceiver dpd, clgc and cfr
Hide thumbs Also See for ADRV9029:
Table of Contents

Advertisement

Preliminary Technical
Data
Select Error
The DPD recovery actions configured in the firmware on startup are listed in Table 9.
Table 9. Default Recovery Action Matrix
Metric
Mean TU Power (Pre-
DPD)
Peak TU Power (Pre-
DPD)
Mean Tx Power (Post-
DPD)
Peak Tx Power (Post-
DPD)
Mean ORx Power
(Post-DPD)
Peak ORx power (Post-
DPD)
Pre-DPD Capture Tx to
ORx EVM (Direct EVM)
Post-DPD Capture Tx
to ORx EVM (Indirect
EVM)
Indirect Error
Select Error
NOTE: The recovery actions follow a many-to-one mapping. Each of the four columns in the table indicate error conditions and
each error condition has a unique metrics-mask to which multiple fault condition metrics can be mapped by 'OR'ing the metrics.
For example, in the matrix shown below, persistent error 0 looks for violation of lower thresholds from either indirect EVM,
mean TU power OR Peak Tx power, whereas persistent error1 looks for high threshold violations from indirect EVM only to
trigger a recovery action.
Error
Error0 - Fault
Condition
condition threshold0
violated once
Recover Action if
Recover Action if
Low Threshold is
Low Threshold
Violated Once
Violation Persists
Abandon DPD LUT
Take no action
Update
Abandon DPD LUT
Take no action
Update
Abandon DPD LUT
Take no action
Update
Abandon DPD LUT
Take no action
Update
Abandon DPD LUT
Take no action
Update
Abandon DPD LUT
Take no action
Update
Take no action
Take no action
Take no action
Take no action
Abandon DPD LUT
Abandon DPD LUT
Update
Update + Revert LUTs
to unity + Reset DPD
adaptation state + HW
reset DPD actuator
Abandon DPD LUT
Abandon DPD LUT
Update
Update + Revert LUTs
to unity + Reset DPD
adaptation state + HW
reset DPD actuator
Persistent0 – Fault
Condition Threshold0
violated persistenly
Greater Than
3%
Recover Action if
High Threshold is
Violated Once
Take no action
Take no action
Take no action
Take no action
Take no action
Take no action
Take no action
Take no action
Take no action
Take no action
Error1 - Fault
condition threshold0
violated once
Rev. PrA | Page 25 of 82
13%
10
Recover Action if
High Threshold
Violation Persists
Take no action
Take no action
Take no action
Take no action
Take no action
Take no action
Take no action
Take no action
Take no action
Take no action
Persistent1 – Fault
Condition Threshold0
violated persistenly