Connect Power To A Pa-800 Series Firewall - PaloAlto Networks PA-800 Series Hardware Reference Manual

Hide thumbs Also See for PA-800 Series:
Table of Contents

Advertisement

Connect Power to a PA-800 Series Firewall Overview

Connect Power to a PA-800 Series Firewall

To avoid injury to yourself or damage to your Palo Alto Networks
that resides on the hardware, read the
STEP 1 |
Remove the nut and star washer from the ground stud.
STEP 2 |
Crimp a 14AWG ground cable to a ring lug (cable and lug not included) and then aach the
ring lug to the ground stud on the firewall. Replace the star washers and nuts and torque to
25 in-lbs. Connect the other end of the cable to earth ground.
STEP 3 |
Connect the AC power cord to the power input on the back of the firewall. On a PA-850
firewall, connect a second power cord to the second power input.
STEP 4 | (PA-850 firewall only)
STEP 5 |
Connect the other end of the power cord to an AC power source. Aer power is connected,
the firewall powers on as indicated by the PWR LED on the front of the firewall.
STEP 6 | (PA-850 firewall only)
the second power supply also turns green.
Connect the second power cord through a different circuit breaker to provide power
redundancy and to allow for electrical circuit maintenance.
PA-800 Series Next-Gen Firewall Hardware Reference
Product Safety
Secure the power cords to the power supplies using the Velcro straps.
Connect the second power cord to an AC power source; the LED for