OPERATOR'S MANUAL
TORQUE DATA MANAGEMENT SYSTEM (TDMS)
FOR USE WITH TDMS SOFTWARE (VERSION 4.0.X)
Part Number 34342 | Issue 11 | Original Instructions (English)

Advertisement

Table of Contents
loading

Summary of Contents for norbar T-Box 43236

  • Page 1 OPERATOR’S MANUAL TORQUE DATA MANAGEMENT SYSTEM (TDMS) FOR USE WITH TDMS SOFTWARE (VERSION 4.0.X) Part Number 34342 | Issue 11 | Original Instructions (English)
  • Page 3: Table Of Contents

    Introduction Features and Functions Upgrading TDMS from an older version Installing TDMS Connecting a T-Box XL™ to TDMS Connecting Other Norbar Torque Measuring Instruments to TDMS Disconnecting a T-Box XL™ from TDMS Departments (Customers) Rename Departments Add Department (Customer) Rename Department (Rename Customer)
  • Page 4 Work ID (Including Statistics & Histogram) View Work ID Tests List Tools for a Work ID View Statistics SPC Calculations View Histogram Calibration Menu Calibration Options List Tools Requiring Recalibration List Tools with Calibration Data and no Certificate Create Calibration Certificate from T-Box XL™ Calibration Data ISO 6789 Tool Type Non-ISO (Other) Tool Type Create Declaration of Conformance from T-Box XL™...
  • Page 5: T-Box Software Compatibility

    Norbar standard Tool Templates for N∙m, lbf∙ft, lbf∙in & kgf∙cm are supplied pre-loaded. • Generate calibration certificates from other Norbar instruments (e.g. TTT, TST & Pro-Test) via RS232. Database for archiving of data for calibration (and Use) of Torque Tools.
  • Page 6: Upgrading Tdms From An Older Version

    Select Database menu then select Backup. Enter backup file name and click Save. Uninstall the old version of TDMS. On your computer go to Control Panel – Programs and Features – Select Norbar TDMS version X.X – Click ‘Uninstall’ (or ‘Remove’) and then click ‘Yes’ to confirm you want to un-install TDMS.
  • Page 7: Installing Tdms

    INSTALLING TDMS Plug Norbar USB Flash Drive into PC. Go to START – MY COMPUTER and click Removable Disk (?). NOTE: You may need administrative privileges to be able to install the software. Open SetupNorbarTDMS.4.0.X (where X represents the latest software revision number).
  • Page 8 The license agreement is shown. Read and click I accept the agreement to proceed. Click Next. NOTE: For 64 bit versions the destination location will be C:\Program Files (x86)\Norbar\TDMS. The destination location is shown. Change location if required. Click Next.
  • Page 9 The start menu folder is shown. Change the folder name if required and click Next. NOTE: For 64 bit versions the destination location will be C:\Program Files (x86)\Norbar\TDMS. The ready to install screen is shown. Click Install. If Windows Mobile Device Centre is not installed the above message will be shown. Click No.
  • Page 10 The following “ActiveSync” is only required for Windows ® If a newer version of ActiveSync is required the above message will be shown. Click OK. The ActiveSync Welcome screen is shown. Click Next. The ActiveSync License Agreement screen is shown. Read then click I accept the terms in the license agreement.
  • Page 11 The ActiveSync Customer Information screen is shown. Enter User Name and Organisation. Click Next. The ActiveSync Ready to Install the Program screen is shown. Click Install. The ActiveSync setup is complete. Click Finish.
  • Page 12 Windows ® 7, 8.1 & 10 computers require “.NET Framework”. If required select control panel then programs and features to ensure “.NET FRAMEWORK” is ON. To adjust select Turn Windows features on or off. Internet access may be required for the computer to obtain the latest software updates. For Windows XP click ‘restart the computer now’.
  • Page 13: Connecting A T-Box Xl™ To Tdms

    The right pane is used to show results. TDMS comes with a Sample department, Sample Tool & Sample Tool Template already created. These are for information only and should be deleted when not required. Norbar standard Tool Templates for N∙m, lbf∙ft, lbf∙in & kgf∙cm are also pre-loaded.
  • Page 14 Plug USB host cable (part no 39483 supplied with T-Box XL™) between USB Type B connector on the back of the T-Box XL™ and the USB Type A connector on a PC USB Type B connector Before T-Box XL™ is connected, the bottom left of the TDMS window will show: Switch on T-Box XL™.
  • Page 15: Connecting Other Norbar Torque Measuring Instruments To Tdms

    CONNECTING OTHER NORBAR TORQUE MEASURING INSTRUMENTS TO TDMS Norbar instruments such as TTT, TST, & Pro-Test can be connected to TDMS with an RS232 interface cable (part no 39264). The TruCheck™ Plus must use RS232 interface cable (part no 39297). These cables are included with the Instruments when purchased new from Norbar.
  • Page 16: Departments (Customers)

    DEPARTMENTS (CUSTOMERS) Rename Departments Departments represents the name of the structure that holds the tools being processed; the name ‘departments’ represents the areas of use within a single factory. For a Calibration laboratory environment the ‘departments’ name could be changed to ‘customers’; other names will suit different applications.
  • Page 17: Add Department (Customer)

    Add Department (Customer) Right click Departments (Customers) icon to show the drop down menu. Select Add Department (Add Customer) from the drop down menu. Enter required Department (Customer) name or identification and press enter.
  • Page 18: Rename Department (Rename Customer)

    Rename Department (Rename Customer) Right click on the Department (Customer) to show the drop down menu. Select Rename Department (Rename Customer). Enter new Department (Customer) name or identification and press enter.
  • Page 19: Delete Department (Delete Customer)

    Delete Department (Delete Customer) Right click on the Department (Customer) to show the drop down menu Select Delete Department (Delete Customer). If a Department (Customer) has tools and data associated with it, you will see the following message. Select Yes, No or Cancel as required.
  • Page 20: Synchronize Department (Customer)

    Synchronize Department (Customer) Synchronize Department (Customer) receives any calibration and test data for any tool from the T-Box XL™ into TDMS and then TDMS sends back the Department Tools, Tool Templates, Targets & Transducer data. This option is only active when ‘USB Connected’ is shown in the bottom left hand corner of TDMS after connecting to a T-Box XL™...
  • Page 21: Set Name & Address For Department (Customer)

    Set Name & Address for Department (Customer) The Name & Address set will be specific to one Department (Customer). If set the Name & Address will appear on all calibration certificates created for a Tool in that Department (Customer). Right click on the Department (Customer) to show the drop down menu. Click Set Department (Customer) Name &...
  • Page 22: Adding A Tool To A Department (Customer)

    Adding a Tool to a Department (Customer) Right click on a department (Customer) to show the drop down menu & click Add Tool (or click Enter Tool Serial Number which could be entered with a bar code reader (not supplied). Choose a Tool Template from the drop down menu to assign to that tool.
  • Page 23: Tools

    TOOLS Expand the Departments (Customers) tree and right click on the required Tool and select the required option from the drop down menu (Or select...
  • Page 24: Rename Tool

    Rename Tool Right click the Tool in the left hand tree structure to show the drop down menu. Select Rename Tool. Type in serial number and press Enter. Change Tool Template Right click the Tool in the left hand tree structure to show the drop down menu. Select Change Tool Template.
  • Page 25: View Tool Template

    View Tool Template Right click the Tool in the left hand tree structure to show the drop down menu. Select View Tool Template. Select OK. Scrap Tool 1. Right click the Tool in the left hand tree structure to show the drop down menu. 2.
  • Page 26: Delete Tool

    Delete Tool Right click the Tool in the left hand tree structure to show the drop down menu. Select Delete Tool to show the screen below. Select Yes, No or Cancel.
  • Page 27: Find A Tool

    Find a Tool Right click the Departments in the left hand tree structure to show the drop down menu. Select Find a Tool. Enter the Tool Serial Number and select OK. The Tool will be highlighted in the left hand tree structure.
  • Page 28: Tool Lists

    Tool Lists 1. Right click the Departments in the left hand tree structure to show the drop down menu. 2. Select List Tools and the Tool List will be displayed in the right pane 3. The Tool List can be printed or copied. Individual department Tool Lists can be produced by right clicking the individual department name and again selecting List Tools.
  • Page 29: Tool Templates

    TOOL TEMPLATES There are 2 variants of Tool Template: • ‘ISO 6789’ for Torque Wrenches & screwdrivers • ‘Other’ Type Tool Templates for PneuTorques, EvoTorques etc. When a Tool Template is attached to a Tool and sent to a T-Box XL™ when synchronizing, the Tool can be selected on the T-Box XL™...
  • Page 30 Right click in the stored Tool Templates window (right pane) to show the drop down menu. 4. Select Add Template. From the ‘Tool’ tab enter the Model # and Description for the new tool Select the Tool Type drop down and select the Tool Template.
  • Page 31 12. Select the ‘Test’ tab 13. Select Modes Available by ticking / un-ticking the boxes. Only the modes ticked (selected) will be available when the Tool Template is used on a T-Box XL™. 14. Enter Number of Tests. This is the number of readings taken at each Target value. This is greyed out for ‘ISO 6789’...
  • Page 32 20. Select the ‘Setting Values’ tab 21. Click Add Setting to Certificate tick box to add a setting to the certificate i.e. pressure. This is greyed out for ‘ISO 6789’ Tool Types. Enter Setting Units e.g. P.S.I. Enter Default Setting Values for each Set Point. The values can be changed during the calibration if necessary.
  • Page 33 22. Select the ‘Uncertainty’ Note: Uncertainties are greyed out for ‘Other’ Tool Type. They are also not used for ISO 6789-1:2017 Declarations of Conformance tests so can be left blank if not performing ISO 6789-2:2017 Certificates of Calibration on this model of tool. 23.
  • Page 34: Uncertainty Test Data

    Uncertainty Test Data To View/Use uncertainty test data, press the Test Data button next to the respective uncertainty value from the tool template ‘Uncertainty’ tab. This lists by date and time individual uncertainty tests which have been performed on this model of tool. In the above example 3 reproducibility uncertainty tests have been performed on 2 different tools of model number 11034.
  • Page 35 To view individual tests results, double click on the test in the list. This shows the readings taken during that test and the calculated uncertainty value for that individual test.
  • Page 36: Modify Tool Template

    Modify Tool Template Select the Define menu then select Tool Templates (or select Right click the Tool Template to show the drop down menu then select Modify Template. Make changes (see Add Tool Template section for more information) then select OK.
  • Page 37: Delete Tool Template

    Delete Tool Template Select the Define menu then select Tool Templates (or select Right click the Tool Template you wish to delete to show the drop down menu. Select Delete Template. Select Yes, No or Cancel. If a Tool Template has been assigned to a Tool, you will see the following message. Refer to the Delete Tool section for more information.
  • Page 38: Targets

    TARGETS A Target is a Torque value which has an upper and lower limit. To obtain SPC data on a Work ID (i.e. USE), a Target must be in use when the test results are being taken. Select the Define menu then select Targets (or select The targets are shown in the right hand pane.
  • Page 39: Add Target

    Add Target Select the Define menu then select Targets (or select Targets are shown in the right hand pane. Right click on a target to show the drop down menu. Select Add Target. Ensure the cursor is blinking in the Name entry box and Type required text. Select the Description entry box and enter the required text.
  • Page 40 Select the Upper Limit entry box and enter the required value (up to 2 decimal places i.e. 4.15). This is the Torque Upper Limit as a percentage of the Target value. Select the Lower Limit entry box and enter the required value (up to 2 decimal places i.e. 3.85). This is the Torque Lower Limit as a percentage of the Target value.
  • Page 41: Modify Target

    Modify Target Select the Define menu then select Targets (or select Targets are shown in the right hand pane. Right click on a Target to show the drop down menu. Select Modify Target. Refer to the Add Target section for more information. Make necessary changes then select OK Delete Target Select the Define menu then select Targets.
  • Page 42: Transducers

    TRANSDUCERS Any transducers used for ISO 6789:2017 Calibrations or Conformances or non-ISO Calibrations should be added to the Transducer register. Note: If any of the transducers are not SMART, entering either of the mV/V values will enable them to synchronise with the T-Box XL™ instrument. Add Transducer Select Define menu then select Transducers (or select...
  • Page 43: Edit Transducer

    Edit Transducer Select the Define menu then select Transducers (or select Transducers are shown in the right hand pane. Right click on a Transducer to show the drop down menu. Select Edit Transducer. The Edit Transducer screen is shown. See Add Transducer section for more information. Make required changes then select OK...
  • Page 44: Delete Transducer

    Delete Transducer Select the Define menu then select Transducers (or select Transducers are shown in the right hand pane. Right click on a Transducer to show the drop down menu. Select Delete Transducer. Select Yes, No or Cancel.
  • Page 45: Measurement Devices

    MEASUREMENT DEVICES Any measurement devices used for ISO 6789:2017 Calibrations or Conformances or non-ISO Calibrations should be added to the Measurement Device register. Note: A measurement device can be a display instrument (e.g. a T-Box XL™), which connects to external transducers listed in the transducer register and can also be a self-contained device with its own display and integral transducer.
  • Page 46: Edit Measurement Device

    Integrated System (e.g. Pro-Test):- Fill in:- Serial Number Model Integrated Transducer Certificates Number/s Transducer Uncertainty Transducer Uncertainty Interval Edit Measurement Device Select the Define menu then select Measurement Devices (or select Measurement Devices are shown in the right hand pane. Right click on a Measurement Device to show the drop down menu.
  • Page 47 Select Yes, No or Cancel.
  • Page 48: Work Id (Including Statistics & Histogram)

    WORK ID A Work ID is a name of a collection of tests done on an application e.g. Lorry Axle. A Work ID can also be added to a calibration i.e. to identify the person who carried out that calibration. Statistical Process Control (SPC) can also be performed on the archived Work or Calibration data as well as the ability to view histograms of the archived data.
  • Page 49: List Tools For A Work Id

    List Tools for a Work ID Select Define menu then select List Tools for a Work ID. Enter the Work ID you are looking for & select OK. Double click on the Work ID in the left hand tree structure to view the results (or graph) in the right hand pane.
  • Page 50: View Statistics

    View Statistics Right click the Work ID for a Tool in the left hand tree structure to show the drop down menu. Select View Tests. Select the Tests to view Statistics for by left clicking on the first test, then hold down shift and left click on the last test.
  • Page 51: Spc Calculations

    SPC Calculations Term Mathematical equation Comment No readings The number of readings Minimum The smallest reading. Maximum The largest reading. Mean Sum of readings / N This is the average reading. The square root of: Also known as standard deviation, this shows how Sigma Σ(reading-mean)²...
  • Page 52: View Histogram

    View Histogram Right click on a Work ID for a Tool in the left hand tree structure to show the drop down menu. Select View Tests. Select the Tests to view a Histogram for by left clicking on the first test, then hold down shift and left click on the last test.
  • Page 53: Calibration Menu

    CALIBRATION MENU Calibration Options Select Calibration menu then select Options (or select icon). Select the General tab, this contains header information for all certificates. The Next Certificate Number is generated automatically. The Standard can be entered. This will be included on non-ISO certificates. The Company Name and address (shown as Header Line 1, 2 and 3) can be entered, these will appear at the top of the certificate.
  • Page 54 Select the Recalibration tab. Select Recalibration Frequency to set specific value for the tool. Select Warn on recalibration required at to set value for recalibration warning. Select the Text(1) tab. Use Text(1) to Text(10) to enter extra details that will appear on the calibration certificate. Use the Include This option to include / exclude text as required.
  • Page 55: List Tools Requiring Recalibration

    List Tools Requiring Recalibration Tools requiring re-calibration will be preceded by a warning symbol in the left hand window (pane). This symbol will only appear if the Recalibration Frequency has been specified in the Calibration Options settings and the last time the Tool was calibrated is less than the number specified on Warn on recalibration required at within the Calibration Options.
  • Page 56: List Tools With Calibration Data And No Certificate

    List Tools with Calibration Data and no Certificate Select the Calibration menu then select List Tools requiring Recalibration. Select the tool in the right hand pane as shown below. Double left click on a Tool to highlight that Tool in the left pane.
  • Page 57: Create Calibration Certificate From T-Box Xl™ Calibration Data

    Create Calibration Certificate from T-Box XL™ Calibration Data Calibrate a Tool on T-Box XL™ and then Synchronize with TDMS. Select Calibration Data to show results in the right hand pane. Right click on the Calibration Data to show the drop down menu. Select Create Calibration Certificate NOTE: icon will be shown in front of a Tool that has been calibrated but no certificate...
  • Page 58 10. If adding an additional calibration the Certificate Text screen will appear. Use the pull down option to select As found, As left or enter your own text. Select OK. 11. Select the Equipment tab to review the calibration equipment used to perform the calibration Note: Check the current certificate numbers are correct and that the uncertainty values are correct.
  • Page 59: Iso 6789 Tool Type

    Create Certificate – ISO 6789 Tool Types For ISO 6789 tool types, make sure the respective tool template has its uncertainty values entered under the tool template ‘Uncertainty’ tab. If any of the required uncertainty values are equal to zero, the following message will appear:- If the uncertainties set to zero are valid (e.g.
  • Page 60 If the measurement system and temperature comply with ISO 6789-2:2017, the certificate will be generated:-...
  • Page 61: Non-Iso (Other) Tool Type

    Create Certificate – Non-ISO (Other) Tool Type For non-ISO (Other) tool type, the respective tool templates uncertainty values under the ‘Uncertainty’ tab are not needed, so are greyed out. If the tool was calibrated below 18°C or above 28°C the following message will appear:- Pressing ‘Yes’...
  • Page 62: Create Declaration Of Conformance From T-Box Xl™ Conformance Data

    Create Declaration of Conformance from T-Box XL™ Conformance Data Note: Declarations of Conformance can only be produced for ISO 6789 tool types. Declarations of Conformance do not use uncertainty values in the respective tool templates ‘Uncertainty’ tab. Conformance test a Tool on T-Box XL™ and then Synchronize with TDMS.
  • Page 63 10. If adding an additional conformance the Certificate Text screen will appear. Use the pull down option to select As found, As left or enter your own text. Select OK. 11. Select the Equipment tab to review the calibration equipment used to perform the conformance test Note: Check the current certificate numbers are correct and that the uncertainty values are correct.
  • Page 64 If the measurement device and transducers uncertainty values are too high, the following message will appear:- Check the measurement device and transducer uncertainty values are correct. The measurement systems maximum relative error can be no greater than ¼ of the tools maximum permissible relative deviation.
  • Page 65: Calibrate (Via Rs232)

    Calibrate (via RS232) This option is for generation of certificates via the RS232 interface. Ensure the Calibration Options are set up correctly. Calibrate (via RS232) is available for all tool types. Select the tool to be calibrated, then select Calibrate (via RS232) from the right mouse button menu Select or Enter an Inspector (this must be...
  • Page 66 9. Select Readings tab Press ‘Start RS232 Capture’ button Perform calibration, sending readings via RS232 A reading can be deleted by pressing the ‘Delete Last Reading’ button Continue taking readings until the calibration is complete 10. Press ‘Create Certificate’ button Note: Calibrate (via RS232) can be used for ISO 6789 and non-ISO (Other) tool types.
  • Page 67: Conformance (Via Rs232)

    Conformance (via RS232) This option is for generation of declarations of conformance via the RS232 interface. Ensure the Calibration Options are set up correctly. Conformance (via RS232) is only available for ISO 6789 tool types. 1. Select the tool to be calibrated, then select Conformance (via RS232) from the right mouse button menu Select or Enter an Inspector (this must be...
  • Page 68 9. Select Readings tab Press ‘Start RS232 Capture’ button Perform conformance test, sending readings via RS232 A reading can be deleted by pressing the ‘Delete Last Reading’ button Continue taking readings until the conformance test is complete 10. Press ‘Create Certificate’ button...
  • Page 69: Certificates

    CERTIFICATES View Certificate Find the tool in the left pane. If required the left pane right mouse button menu and select Find Certificate to search. 2. Select certificate then either double click or select View Certificate from the right mouse button menu 3.
  • Page 70 4. To view the tools uncertainty values which were used to generate a specific certificate, select ‘Uncertainty Values Used’ and then ‘View’ from the right mouse button menu. The 5 uncertainty values shown are the values which were stored in the respective tool template at the time the certificate was generated.
  • Page 71: Delete Certificate

    Delete Certificate Find the tool in the left pane. Select certificate, then select Delete Certificate from the right mouse button menu Select Yes, No or Cancel.
  • Page 72: View Air Pressure Graph

    View Air Pressure Graph Find the tool in the left pane. Select certificate then right click to View Menu. Select View P.S.I. Graph. TIP: Only one air pressure graph can be created from each certificate. If more than one graph is required then create separate certificates.
  • Page 73: Graphs

    GRAPHS Use T-Box XL™ ‘Graph’ mode to take results & transfer results to TDMS. Find the tool in the left pane. Find the graph data then double left click or press + to expand. Select graph then double left click right click to View Menu.
  • Page 74 Right click on the graph to show a drop down menu. View options include: View as Torque/Angle v Time View as Torque v Angle View as Torque v Speed. The Print option will send the graph to a printer. 9. The Copy to Clipboard option will send the graph to the clipboard.
  • Page 75: Options Menu

    OPTIONS MENU USB Synchronization Options This option controls the data (Tools, Tool Templates, Targets, Transducers, Test Data (Work ID), Calibration Data and Graphs) sent between TDMS & T-Box XL™. Use the Synchronize Now and Send Updates Now options to control the data sent between single or multiple T-Box XLs. Ensure TDMS is connected to T-Box XL™, see bottom left of TDMS screen.
  • Page 76: Change Certificate Language

    Change Certificate Language The language will change for all New and Archived Calibration Certificates. Select Options then select Certificate Language then select language. TIP: If a certificate was open before the language change, close the certificate and re-open. Reset Test Data Read Index This should only be selected if you are experiencing loss of data transfer between the T-Box XL™...
  • Page 77: Copy From Usb Stick Options

    COPY FROM USB STICK OPTIONS For remote data transfer (without a USB cable) the data can be sent via a USB stick (memory drive). The files on the USB stick include: File name Contents xxxxxxxAudit.txt Stores the T-Box XL™ results (data). Where xxxxxx represents the T-Box XL™ serial number. Instrument.txt Stores the instrument settings (not used by TDMS).
  • Page 78: Load Template File

    Load Template File Select Options then select Load Template File. Browse to the Template.txt file then select Open.
  • Page 79: Load Tools File

    Load Tools File Select Options then select Load Tools File. Browse to the Tools.txt file then select Open.
  • Page 80: Load Targets File

    Load Targets File Select Options then select Load Targets File. Browse to the Targets.txt file then select Open.
  • Page 81: Load Audit File

    Load Audit File Select Options then select Load Audit File. Browse to the XXXXXXAudit.txt file (where XXXXXX is the T-Box XL™ serial number) and select Open.
  • Page 82: Set Printer Margins

    Set Printer Margins To ensure compatibility with different printers where printouts of reports do not fit on the page: Select Options menu then select Set Printer Margins. Enter desired values then select OK.
  • Page 83: Database Menu

    DATABASE MENU Database / Backup It is recommended to backup the database regularly for security purposes and before updating the TDMS software. Select Database menu then Backup. Enter file name and select Save. Database / Restore Select Database menu then Restore. Select stored file and select Open. Database / Reload Standard Templates The standard templates are built into the TDMS software.
  • Page 84: Database / Update Application

    Database / Update Application Using this feature T-Box XL™ software can be updated. Ensure current T-Box XL™ is software 2.X.X.X or later. If not contact Norbar for assistance. Connect T-Box XL™ to computer using USB cable. In TDMS select Database and Update Application.
  • Page 85: View Menu

    VIEW MENU The View menu uses the Information in the right pane. Ensure the right pane contains the required information before using the View menu. View Option Details Select graph in the left pane, so details appear in the right pane. View Graph Select View then select View Graph (or select icon).
  • Page 86: About Tdms

    ABOUT TDMS Select the icon on the TDMS shortcut bar. The software version number will be shown. Click OK to cancel. Click Database File… to show where the TDMS database is stored. The default location is: NOTE: For 64 bit versions, this may be shown as C:\ProgramData(x86)\TDMS\NorbarTDMS.sqlite...
  • Page 87: Key To Shortcut Icons

    KEY TO SHORTCUT ICONS These can be used for quick selection from the shortcut bar. Icon Shortcut to Define Tool Templates (Ctrl+E) Define Targets (Ctrl+G) Define Transducers (Ctrl+D) Define Measurement Devices Add Tool Calibrate (Via RS232) (Ctrl+T) Conformance (Via RS232) Calibration Options (Ctrl+O) Synchronise Now Send Updates Now...
  • Page 88: Trouble Shooting

    TROUBLE SHOOTING Problem Likely Solutions Unplug the USB Host lead, wait at least 10 seconds and re-insert whilst TDMS has TDMS displays USB been launched and T-Box XL™ is displaying the Measure screen (Hot-Plug). detected / Not Connected and will Ensure that you disconnect from USB correctly before removing the lead.
  • Page 89: Glossary Of Terms

    An output used to provide a stop signal for an external pneumatic, hydraulic or Tool Stop electric tool. Tool Templates A template holding full details of the tool. All Norbar tools are included. Tool Type Classification from ISO 6789. Universal Serial Bus.
  • Page 90 Tel + 86 21 6145 0368 Tel + 61 (0)8 8292 9777 Email enquiry@norbar.com.au Email sales@norbar.com.cn NORBAR TORQUE TOOLS INDIA PVT. LTD NORBAR TORQUE TOOLS INC Plot No A-168, Khairne Industrial Area, 36400 Biltmore Place, Willoughby, Thane Belapur Road, Mahape, Ohio, 44094 Navi Mumbai –...

This manual is also suitable for:

T-box xl 43258

Table of Contents