Using The Pc Interface (Banner Sensors Gui); Supplied Software; Communications Connections; Accessing The Gui - Banner A-GAGE EZ-ARRAY Instruction Manual

Two-piece sensing array with 2 analog and 2 discrete outputs, plus serial output
Hide thumbs Also See for A-GAGE EZ-ARRAY:
Table of Contents

Advertisement

A-GAGE EZ-ARRAY
Instruction Manual

5. Using the PC Interface (Banner Sensors GUI)

The full functionality of the EZ-ARRAY is available by making
use of the PC interface (the graphic user interface, or "Banner
Sensors GUI"). Refer to Section 1 for a full description of the
available sensing modes and other features.
The sensor is easily configured using a Windows
style program via the Banner Sensors GUI software and a
PC-compatible computer (running Windows XP or 2000; GUI
software version 1.2 will also be compatible with Vista

5.1 Supplied Software

The PC interface software for configuring the EZ-ARRAY is
included on the CD packed with the receiver, entitled Banner
Sensors GUI (p/n 76978).
For the most recent software version, visit
BannerEngineering.com
and enter "Banner Sensors GUI" in the
search field. Install the software (version 1.1 at this writing) onto
your hard drive; the installer will automatically load the software
into a folder titled "Banner Engineering\Banner Sensors GUI"
onto your computer. If the CD is used, inserting it into your CD
drive will auto-launch the GUI installation and place the icon
onto your desktop.
Double-click on the Banner Sensors GUI icon
the program. The main menu screen appears. Verify that
A-GAGE
EZ-ARRAY is displayed in the Select a Sensor field
®
of the screen.
Verify that A-GAGE
®
EZ-ARRAY
is displayed in the
Select a Sensor field
Figure 5-1. Banner Sensors GUI (PC Interface) main menu screen
Banner Engineering Corp.
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164

5.2 Communications Connections

Connect the serial cable from your receiver to your PC, using an
RS485-to-RS232 adapter, such as the model INTUSB485-1 USB
menu-
®
serial adapter listed in Section 2.2. (Instructions for configuring
the adapter are included with the packaging for the adapter.)
An operating EZ-ARRAY system must be connected before the
).
®
software displays will open.

5.3 Accessing the GUI

With the sensor pair powered up and connected to your PC (as
described in Section 5.2), go to Sensor > Connect (Ctrl + N).
The Alignment/Status screen appears, providing a snapshot of
www.
the current sensing alignment status, including the status of each
array beam, total numbers of blanked, made and blocked beams,
the selected measurements and their values (see Figure 5-2).
The Alignment/Status screen has three pull-down menus:
Sensor, Options, and Help.
Sensor Menu (Alignment/Status screen)
When the Alignment/Status screen is active, the Sensor menu
to launch
provides the options Setup (Ctrl + S), which is used to modify
or view a sensor configuration, Connect/Disconnect (Ctrl + N),
which connects (or disconnects) the PC to the sensor, and Exit
(Ctrl + Q). When a setup screen view is active, the Sensor menu
has other options (see Figures 5-3 and 5-5).
NOTE: Most GUI Setup options are not available until the
Click here to
exit program
Figure 5-2. EZ-ARRAY Alignment/Status screen
Connect function has linked the PC to a sensor pair.
Gray circles
Green circles
denote blanked
denote "made"
beams in the array
(clear) beams
PC Interface
Red circles
denote blocked
beams
23
P/N 130426 Rev. D

Advertisement

Table of Contents
loading

Table of Contents