Peg Survey
Measure points
step-by-step
Step
Description
1.
Enter the reflector height (hr:) for the backsight point, if required.
2.
Aim at backsight point and press Meas Pt.
3.
Depending on the measurement sequence selected, enter a desired
backsight or foresight point ID (PtID:). Cont saves the point ID and
proceeds to the measurement screen.
4.
Enter the reflector height (hr:) for the point, if required.
5.
Aim at target point and press Meas Pt.
6.
Decide whether to measure an additional point:
•
No Repeat steps 2. and 5. until all sets are measured.
•
Yes Repeat steps 3. to 5. with a new point.
A maximum of 7 additional points can be measured.
7.
If the tolerances after a set are not met, the user has the option to continue
with the measurements or reject the data.
•
Reject to reject the measurements and remeasure the set again.
•
Accept to accept the result and continue with the next set.
Next step
After each set the Tolerances Met, or the Out of Tolerance screen displays.
FlexLine/FlexLine plus, 16