Peg Survey
Measure points
step-by-step
Step
Description
1.
Enter the reflector height (hr:) for the backsight point, if required.
2.
Aim at backsight point and press Meas Pt.
3.
Depending on the measurement sequence selected, enter a desired
backsight or foresight point ID (PtID:). Cont saves the point ID and
proceeds to the measurement screen.
4.
Enter the reflector height (hr:) for the point, if required.
5.
Aim at target point and press Meas Pt.
6.
Decide whether to measure an additional point:
No Repeat steps 2. and 5. until all sets are measured.
Yes Repeat steps 3. to 5. with a new point.
A maximum of 7 additional points can be measured.
7.
If the tolerances after a set are not met, the user has the option to continue
with the measurements or reject the data.
Reject to reject the measurements and remeasure the set again.
Accept to accept the result and continue with the next set.
Next step
After each set the Tolerances Met, or the Out of Tolerance screen displays.
FlexLine/FlexLine plus, 16