Service Chart - Grundfos AMG Series Installation And Operating Instructions Manual

Mixers and flowmakers
Hide thumbs Also See for AMG Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

8.3 Service chart

Service instructions
Keep the motor housing
clean to ensure adequate
Electric
cooling. The motor housing
motor
must only be dismantled by
Grundfos.
Power sup-
ply cable
In case of wear, replace the
lip seal and the wear ring.
Gearbox
If the oil contains water, re-
place the shaft seal.
Propeller
Spray the winch with a pro-
tective coating of oil at regu-
Winch
lar intervals to prevent corro-
sion.
Regular oiling or greasing in-
Lifting wire
creases the life of the wire.
Always check that all screws
in the motor bracket are prop-
erly tightened.
Screws
Check the screws in the bot-
tom fixation bracket/bottom
fixation plate every time the
tank is empty.
Lubrication
The roller bearings do not require
maintenance.
They should be replaced if they
become noisy.
Change the oil whenever it con-
tains water or is contaminated.
Change the oil at least every two
years.
If refilling is required refer to the
oil section of this document.
Lubricate the gear teeth and the
bearing bushes twice a year with
an all-purpose grease.
When tightening the screws, re-
new the threadlocker, if necessa-
ry.
Inspection
Check the power supply cable
twice a year for visible damage.
If damaged, the cable must be
replaced by Grundfos.
If the shaft seal housing is not
monitored for leakage, inspect
it every 6 months.
Check the propeller blades reg-
ularly for wear and tear. Re-
move any material wound
around the blades which may
cause uneven running and os-
cillation of the installation. In
case of strong turbulence,
clean it.
Check the wire regularly and al-
ways before using the winch.
Replace the wire, if required.
29