Normal Mode (Mode 0); Wake-Up Mode (Mode 1); Power-Saving Mode (Mode 2) - Ebyte E30-490T20S User Manual

Si4438 490mhz 100mw smd wireless module
Hide thumbs Also See for E30-490T20S:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd
mode-switch, using external interrupt function to get AUX change so that the mode -switch can be realized.
This operation is very flexible and efficient. It is totally designed on the basis of the user MCU's convenience, at the
same time the work load and power consumption of the whole system have been reduced and the efficiency of whole
system is largely improved.

6.2 Normal mode (mode 0)

When M1 = 0 & M0 = 0, module works in mode 0
The module can receive the user data via serial port, and transmit wireless data package of 58 bytes. When the data
inputted by user is up to 58 byte, the module will start wireless transmission. During which the user can input data
continuously for transmission.
When the required transmission bytes are less than 58 bytes, the module will wait 3-byte time and treat it as data
Transm
termination unless continuous data inputted by user. Then the module will transmit all the data through wireless channel.
itting
When the module receives the first data packet from user, the AUX outputs low level.
After all the data are transmitted into RF chip and transmission start , AUX outputs high level.
At this time, it means that the last wireless data package transmission is started, which enables the user to input another
512 bytes continuously. The data package transmitted from the module working in mode 0 can only be received by the
module working in mode 0 or 1.
The wireless receiving function of the module is on, the data packet transmitted from the module working in mode 0 &
mode 1 can be received.
Receiv
After the data packet is received, the AUX outputs low level, 5ms later the module starts to transmit wireless data through
ing
serial port TXD pin.
After all the wireless data have been transmitted via serial port, the AUX outputs high level.

6.3 Wake-up mode (mode 1)

Transmitting
Receiving

6.4 Power-saving mode (mode 2)

Transmitting
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd
When M1 = 0 & M0 = 1, module works in mode 1
The condition of data packet transmission & AUX function is the same as mode 0. The only difference is that
the module will add preamble code before each data packet automatically. The preamble code length depends
on the wake-up time set in the user parameters. The purpose of the preamble code is waking up the receiving
module works in mode 2. Therefore, the data package transmitted from mode 1 can be received by mode 0,
mode1 and mode 2.
The same as that in mode 0.
When M1 = 1 & M0 = 0, module works in mode 2
UART is closed, the module cannot receive any serial port data from outside M CU.
Hence the function of wireless transmission is not available for the module working in this mode.
E30 -490T20S user manual
11

Advertisement

Table of Contents
loading

Table of Contents