Chengdu Ebyte Electronic Technology Co.,Ltd.
Set the Bluetooth broadcast interval of the module, if you permanently save this parameter you need to
Description
send AT+SAVE, otherwise it will only take effect temporarily, the default value is 100ms.
AT+ADV_PARAM=50
Example
OK+ADV_PARAM
Set the broadcast interval to 50ms
6.2.11 AAT+TX_POWER Transmit Power
Query
AT+CON_PARAM?
Setting
AT+CON_PARAM=[para]
para (ASCII) , Bluetooth
connection interval ( ms)
Parameter
Set the Bluetooth connection interval of the module, such as permanently save the parameter need to send
Description
AT+SAVE, otherwise it is only temporarily effective, the default value is 20ms.
AT+CON_PARAM=50
Example
OK+CON_PARAM
Set the Bluetooth connection interval to 50ms
6.2.12 AT+VER? Queries the current software version
Query
AT+VER?
Parameter
[para]Refers to the current software version
AT+VER?
Example
+OK+VER=V1.2.3
The current software version is V1.2.3.
6.2.13 AT+AD Set broadcast data
Query
AT+AD?
Setting
AT+AD=[para]
Copyright ©2012–2023,Chengdu Ebyte Electronic Technology Co.,Ltd.
200
500
1000
2000
Command
20
50
100
Command
Command
Respond
OK+CON_PARAM=[para]
OK+CON_PARAM
Respond
OK+VER=[para]
Respond
OK+AD=[para]
OK+AD
E104-BT09 User Manual
16