7. Instruction Format

In command mode(Mode 2:M1=1, M0=0), it supports instructions below.
(Only support 9600 and 8N1 format when setting)
No.
Instruction format
1
C0 + working parameters
2
C1 C1 C1
3
C2 + working parameters
4
C3 C3 C3
5
C4 C4 C4

7.1 Default Parameter

Model
Frequency
E61-TTL-50
433MHz
Model
Frequency
E61-TTL-1W
433MHz

7.2 Reading Operating Parameters

Instruction format
C1+C1+C1

7.3 Reading Version Number

Instruction format
C3+C3+C3

7.4 Reset Instruction

Instruction format
C4+C4+C4
Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.
C0 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and must
be send in succession. ( Save the parameters when power-down )
Three C1 are sent in hexadecimal format. The module returns the saved parameters and must
be send in succession.
C2 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and must
be send in succession. ( Do not save the parameters when power-down )
Three C3 are sent in hexadecimal format. The module returns the version information and
they must be send in succession.
Three C4 are sent in hexadecimal format. The module will reset one time and they must be
send in succession.
Default parameter values:C0 00 00 18 50 50
Address
Channel
0x0000
Default parameter values:C0 00 00 18 50 50
Address
0x0000
In instruction mode(M0=0,M1=1) ,
User gives the module instruction (HEX format): C1 C1 C1,
Module returns the present configuration parameters.
For example, C0 00 00 18 50 50.
In instruction mode(M0=0,M1=1),
User gives the module instruction (HEX format): C3 C3 C3.
Module returns its present version number, for example C3 61 xx yy.
61 here means the module model (E61 series); xx is the version number and yy refers to the other module features.
In instruction mode(M0=0,M1=1),
User gives the module instruction (HEX format): C4 C4 C4, the module resets for one time.
During the reset process, the module will conduct self-check, AUX outputs low level. After reset completing, the
AUX outputs high level, then the module starts to work regularly which the working mode can be switched or be
given another instruction.
Transmitting
methods
Continuous
0x50
transmitting
Transmitting
Channel
methods
Continuous
0x50
transmitting
Description
Description
Description
User Manual of E61 Series Modules
Illustration
Baud rate
Parity
9600
8N1
Baud rate
Parity
9600
8N1
Transmitting
power
50mW
Transmitting
power
1W
13 / 18