ESAB Aristo Origo Arc 4001i Service Manual page 57

Hide thumbs Also See for Aristo Origo Arc 4001i:
Table of Contents

Advertisement

1.
Welding with the filler wire positive: voltage sensing from the wire
This is the most common arrangement of arc voltage sensing.
V = external voltmeter. R = load resistor.
The control panel must show the same voltage value as shown on the external
voltmeter $0.6 V. Adjust the display value by means of potentiometer R87.
2.
Welding with the filler wire negative: voltage sensing from the wire
V = external voltmeter. R = load resistor.
The control panel must show the same voltage value as shown on the external
voltmeter $0.6 V. Adjust the display value by means of potentiometer R103.
3.
Welding with the filler wire positive or negative: no external sensing from the wire or
workpiece
V = external voltmeter. R = load resistor.
The external voltmeter shows a value 0.2 - 1.6 V higher than the value shown on the
control panel. Do not adjust the value shown on the control panel: this is already
adjusted from 1) above.
ca42f3calarcv
- 57 -
S0740 800 197/E100621/P74