Fault Code Description, Power Source - ESAB Aristo Origo Arc 4001i Service Manual

Hide thumbs Also See for Aristo Origo Arc 4001i:
Table of Contents

Advertisement

Fault
code
20
Memory allocation error
22
Transmitter buffer overflow
23
Receiver buffer overflow
26
Program operating fault
27
Out of wire
28
Stack overflow
29
No cooling water flow
31
No reply from the display unit
32
No gas flow
40
Incompatible units

Fault code description, power source

This manual describes the fault codes for the power source. The fault codes for other units
are described in the manuals for these units.
Code Description
1
EPROM check sum error - program memory error
Check sum test of the program memory, which is run only when initiating the power source
after power-up. This fault does not disable any functions.
The program memory is damaged. This is a serious fault, that can have unforeseen effects.
Action: Restart the power source. If the fault persists, load new software via ESAT. If the
fault still persists, replace circuit board 20AP1, which carries the memory chip.
2
Microprocessor RAM error
The microprocessor is unable to read/write from/to a particular memory address in its
internal memory. This test is performed only on initiation after power-up. This fault does not
disable any functions.
Action: Restart the power source. If the fault persists, replace circuit board 20AP1, which
carries the microprocessor chip.
3
Memory error, external RAM
The microprocessor is unable to read/write from/to a particular memory address in its
external memory. This test is performed only on initiation after power-up. This fault does not
disable any functions.
Action: Restart the power source. If the fault persists, replace circuit board 20AP1, which
carries the microprocessor chip.
4
5 V power supply too low
The unregulated power supply voltage is too low: the smoothing capacitors cannot keep the
voltage up enough for the processor to continue to operate. The processor stops all normal
activities, expecting to be shut down.
Action: Turn off the mains power supply to reset the unit. If the fault persists, check the
power supply to circuit board 20AP1.
ca42f1
Description
Welding
Power
data unit
source
x
x
x
x
x
x
x
x
x
x
x
x
x
- 42 -
Wire feed
Remote
unit
control
unit
x
x
x
x
x
S0740 800 197/E100621/P74

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aristo origo mig 4001i

Table of Contents