Image Flip; Flat Field Correction Function - Omron STC-LBS132POE-SWIR Product Specifications And User's Manual

Gige vision swir cmos poe camera
Table of Contents

Advertisement

11.14

Image Flip

The horizontal flip image can be selected by "ReverseX".
The vertical flip image can be selected by "ReverseY".
GenICam Parameters
ReverseX
ReverseY
11.15

Flat Field Correction Function

When using this function, the
by characteristics of lens (amount of through light difference at center and edge of lens) and characteristics of
unevenness of sensitivity, PRNU) can be correct
light (
When using this function, please follow below procedure after set exposure time (ExposureTime), analog gain
(AnalogGain), black level (BlackLevel).
Please proceed DSNU correction when change exposure time, analog gain or black level.
GenICam Parameters
FFCSelector
FFCEnable
FFCType [FFCSelector]
FFCAuto [FFCSelector]
FFCValueStatus [FFCSelector]
STC-LBS132POE-SWIR
Product Specifications and User's Guide
IBoolean Type
Horizontal flip image ON / OFF selection
Selection: "False" (Horizontal flip is Off), "True" (Horizontal flip is On)
Default: "False" (Horizontal flip is Off)
IBoolean Type
Vertical flip image ON / OFF selection
Selection: "False" (Vertical flip is Off), "True" (Vertical flip is On)
Default: "False" (Vertical flip is Off)
unevenness of
IEnumeration Type
IBoolean Type
IEnumeration Type
IEnumeration Type
IEnumeration Type
black level of camera (DSNU) and shading on image that caused
.
FFC function selection
Offset: DSNU correction
Gain: PRNU correction
Default: Gain
FFC function ON / OFF selection
Selection: "True" (On): selected correction is applied image is
acquired,
"False" (Off): selected correction does not apply
image is acquired.
Default: False
FFC correction value acquiring method is displaying
Pixel: Correction value is acquiring each pixel
(DSNU correction)
Mesh: Correction value is acquiring each 8x8 pixels
(PRNU correction)
FFC auto correction process
Off: Stop correction process
Once: Start correction process
FFC correction result is displaying
"Success" is displaying when DSNU correction is
correctly done.
"Failure" is displaying when power is off or error
occurred while proceeding DSNU correction.
In this case, please do DSNU correction process again.