5.6 Input terminal:P4.00-P4.40
HV590 series inverter has 6 multifunctional digital input terminals (DI1 to DI6), of which DI5
can be used as high-speed pulse input terminal, and HV590 series inverter also has 2 analog
input terminals.If system needs more input/output terminal, it can be equipped with multi-
function input/output expansion card and 1 analog input terminal(AI3x).
Multi-function
terminal(DI7~DI10).
Code
Description/Display
P4.00
DI1terminal function selection
P4.01
DI2 terminal function selection
P4.02
DI3 terminal function selection
P4.03
DI4 terminal function selection
P4.04
DI5 terminal function selection
P4.05
DI6 terminal function selection
P4.06
DI7 terminal function selection
P4.07
DI8 terminal function selection
P4.08
DI9 terminal function selection
P4.09
DI10 terminal function selection 0~59
These parameters are used to set digital multi-function input terminals, as shown in the table below:
Setting
0
No- function
1
Forward command (FWD)
2
Reverse command (REV)
Section V. Parameter Function Table
Fig. 5-5 VF separation schematic diagram
input/output
expansion
0~59
0~59
0~59
0~59
0~59
0~59
0~59
0~59
0~59
Function
card
has
Setting Range
Specification explanation
Set useless terminals to "no function", in order to prevent
misoperation.
The forward jog and reverse jog of the inverter are
controlled via the external terminals.
59
t
Actual voltage fall time
Setting voltage fall time
4
multi-function
Factory
Setting
digit
input
Change
Limite
1
4
9
12
13
2
12
13
14
15