Mounting Hole Dimension; Braking Unit & Braking Resistance - HNC Electric HV590 Series User Manual

Table of Contents

Advertisement

3.2 Mounting hole dimension

3.2.1 Braking unit & Braking resistance
When customers choose the type with braking,there will be braking unit inside the
inverter,maximum braking torque is 50%.Please refer to the table below and choose the matched
braking resistance separately.
Shape DIM
HV590−R40G1/G2
HV590−R75G1/G2
HV590−1R5G1/G2
HV590−2R2G1/G2
HV590−R75G3
HV590−1R5G3
HV590−2R2G3
HV590−3R7G3
HV590−5R5G3
HV590−7R5G3
HV590−011G3
HV590−015G3
HV590−018G3
HV590−022G3
HV590−030G3
HV590−037G3
HV590−045G3
HV590−055G3
HV590−075G3
If you need accessories in the table,please declare in order.
For larger built-in braking torque,please use the HNC braking unit.do ou can refer to HNC
braking unit manual for details.
Other large power models do not contain a built-in braking.If large power model need to be
equipped with braking function,please choose HNC braking unit.
External DC reactor installation:
For HV590 series inverter, external DC reactor can be ordered according to your
needs.When installation,you should tear down copper platoon between DC+1 and DC+2 of
inverter main circuit.And then add reactor between DC+1 and DC+2,wiring between reactor
terminals and inverter terminals DC+1 and DC+2 have no polarity. After installation of dc
reactor,short circuit copper platoon between DC+1 and DC+2 is no more used.
Section IV. Keyboard Operation
Braking unit
Braking
unit
Braking
100W
120W
300W
300W
100W
200W
200W
Standard
built-in
400W
500W
800W
1040W
1560W
4800W
4800W
6000W
9600W
outlay
9600W
6000W
9600W
Table:3-2.1
Quanti
ty
300Ω
1
200Ω
1
100Ω
1
70Ω
1
300Ω
1
300Ω
1
200Ω
1
150Ω
1
100Ω
1
75Ω
1
50Ω
1
40Ω
1
32Ω
1
27.2Ω
1
20Ω
1
16Ω
1
13.6Ω
1
20Ω
2
13.6Ω
2
27
Braking moment %
220
125
125
120
130
125
135
135
135
130
135
125
125
125
125
125
125
135
145

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents