ORiNG TPS-W9124GT-M12X-BP2 -24V-IP54 Quick Installation Manual

ORiNG TPS-W9124GT-M12X-BP2 -24V-IP54 Quick Installation Manual

Industrial ip-54 managed poe ethernet switch

Advertisement

Quick Links

IP -54
EN50155
Switch
Q
I
uick
nstallation
I N D U S T R I A L

Introduction

ORing's Transporter
T M
series managed PoE Ethernet switches are designed
for industrial waterproof applications, such as rolling stock, vehicle, and
railway applications.
TPS-W9124GT-M12X-BP2-24V-IP54
Redundant Ring Ethernet switch with 12x10/100Base-T(X) P.S.E. and
4x10/100/1000Base-T(X) ports which is specifically designed for the
toughest and fully compliant with EN50155 requirement. The switch support
Ethernet Redundancy protocol, O-Ring (recovery time < 10/30ms over 250
units of connection), O-Chain, MRP*NOTE and MSTP/RSTP/STP (IEEE
802.1s/w/D) can protect your mission-critical applications from network
interruptions or temporary malfunctions with its fast recovery technology.
TPS-W9124GT-M12X-BP2-24V-IP54 also support Power over Ethernet, a
system to transmit electrical power up to 30 watts, along with data, to remote
devices over standard twisted-pair cable in an Ethernet network. Each TPS-
W9124GT-M12X-BP2-24V-IP54 switch has 12x10/100Base-T(X) P.S.E.
(Power Sourcing Equipment) ports. P.S.E. is a device (switch or hub for
instance) that will provide power in a PoE connection.
M12X-BP2-24V-IP54 includes 2 sets of bypass ports that protect the network
from failures and Network maintenance by ensuring network integrity during
power loss. And support wide operating temperature from -40 C to 75 C.
TPS-W9124GT-M12X-BP2-24V-IP54 can also be managed centralized and
convenient by Open-Vision, Except the Web-based interface, Telnet and
console (CLI) configuration. Therefore, the switch is one of the most reliable
choices for EN50155 waterproof highly-managed Ethernet application.
*NOTE: This function is available by request only

Package Contents

The device is shipped with the following items. If any of these items is missing
or damaged, please contact your customer service representative for
assistance.
Contents
Pictures
TPS-W9124GT-M12X-BP2
-24V-IP54
CD
Wall-mount Kit
QIG

Preparation

Before you begin installing the device, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Safety & Warnings
When installed outdoors, make sure the connectors on the panel are facing down
to prevent water intrusion.
Do not remove the water-proof casing, and do not touch or move the device
when the antennas are transmitting or receiving signals.
Q I G
TPS-W9124GT-M12X-BP2-24V-IP54
TPS-W9124GT-M12X-BP2
G
uide
-24V-IP54
When installing the device, make sure to keep the radiating at a minimum distance of 20 cm
(7.9 inches) from all persons to minimize the potential for human contact during normal
operation.
is managed
Do not operate the device near unshielded blasting caps or in an otherwise explosive
environment unless the device has been modified for such use by qualified personnel.
Dimension
Unit =mm (Tolerance ±0.5mm)
TPS-W9124GT-
o
o
TPS-W9124GT-M12X-BP2-24V
PWR1 PWR2
R.M.
Ring
Fault
RXD
TXD
N.C.
N.C.
GND
RS-232, 115200bps, 8, N, 1
Console
V2+
N.C
V2-
N.C
Power 2
GND
V1+
N.C
V1-
N.C
Power 1

Panel Layouts

Top View
Number
1
15
1
Reset
3
4
TPS-W9124GT-M12X-BP2-24V
PWR1 PWR2
R.M.
Ring
Fault
LNK/ACT
RXD
TXD
PoE
N.C.
2
5
Speed
N.C.
GND
P4
10
RS-232, 115200bps, 8, N, 1
Console
LNK/ACT
6
PoE
Speed
P3
11
1
V2+
N.C
LNK/ACT
PoE
V2-
N.C
Speed
P2
Power 2
14
7
GND
LNK/ACT
PoE
V1+
N.C
Speed
P1
V1-
N.C
Power 1
4
1
Bottom View
1
1. Wall-mount screw holes
1907-200-JW9124X541-FX010
Tx+
Rx+
4
5
1 BI_DA+
5 BI_DD+
3
6
2 BI_DA-
6 BI_DD-
Reset
3 BI_DB+
7 BI_DC-
2
7
4 BI_DB-
8 BI_DC+
Rx-
Tx-
P1~P12
1
8
G1~G4
LNK/ACT
LNK/ACT
PoE
PoE
Speed
Speed
P4
P8
P12
G4
Power
Failure
Bypass
LNK/ACT
LNK/ACT
PoE
PoE
Speed
Speed
P3
P7
P11
G3
LNK/ACT
LNK/ACT
PoE
PoE
Speed
Speed
P2
P6
P10
G2
Power
Failure
Bypass
LNK/ACT
LNK/ACT
PoE
PoE
Speed
Speed
P1
P5
P9
G1
262.00
90.0
12
1. Reset button
2. Power LED
Tx+
Rx+
4
5
1 BI_DA+
5 BI_DD+
3
6
2 BI_DA-
6 BI_DD-
3 BI_DB+
7 BI_DC-
3. R.M. status LED
2
7
4 BI_DB-
8 BI_DC+
Rx-
Tx-
P1~P12
1
8
G1~G4
LNK/ACT
4. Ring status LED
PoE
Speed
P8
P12
G4
Power
5. Fault LED
Failure
Bypass
LNK/ACT
6. Console port
PoE
Speed
P7
P11
G3
7. Power connector
LNK/ACT
8. PoE Fast Ethernet port
PoE
Speed
P6
P10
G2
Power
9. Gigabit Ethernet port with bypass
Failure
Bypass
LNK/ACT
10. Link/ACT LED for PoE Ethernet port
PoE
Speed
P5
P9
G1
11. Speed LED for PoE Ethernet port
12. Link/ACT LED for Gigabit Ethernet port
13. Speed LED for Gigabit Ethernet port
14. Ground wire
8
13
9
15. PoE status LED for PoE Ethernet port
1
PRINTED ON RECYCLED PAPER
EN50155 Industrial IP-54 managed
PoE Ethernet switch

Installation

Wall-mount
Follow the steps below to install the device to the wall.
Step 1: Screw the Four pieces of wall-mount kits onto bottom side of the switch. A total of four
screws are required.
Step 2: Hold the device upright against the wall.
Step 3: Insert four screws through the holes at the top of the plate and fasten the screws to
the wall.
Instead of screwing the screws in all the
way, it is advised to leave a space of about
2mm to allow room for sliding the switch
between the wall and the screws.

Wiring

For pin assignments of power and console port, please refer to the following tables.

Grounding

Grounding and wire routing help limit the effects of noise due to electromagnetic interference
(EMI). Run the ground connection from the grounding pin on the power connector to the grounding
surface prior to connecting devices.

Power port pinouts

The device supports two sets of power supply and uses the M12 S-coded
4-pin male connector on the front panel for power inputs.
Step 1: Insert a power cable to the power connector on the device.
Step 2: Rotate the outer ring of the cable connector until a snug fit is
achieved. Make sure the connection is tight.

Console port pinouts

The switch has one RS-232 (M12 5pin) console port,
located on the front panel. Use a M12-to-DB9
console cable to connect the console port to your
PC's COM port.

Network Connection

The switch has twelve 10/100Base-T(X) and four 10/100/1000Base-T(X) Ethernet ports in the form
of M12 connector. Depending on the link type, the switch uses CAT 3, 4, 5,5e UTP cables to
connect to network devices (PCs, servers, switches, routers, or hubs). Please refer to the
following table for cable specifications.
Cable
Type
Max. Length
Connector
4-pin female M12
10BASE-T
Cat. 3, 4, 5 100-ohm
UTP 100 m (328 ft)
D-coding connector
4-pin female M12
100BASE-TX
Cat. 5 100-ohm UTP
UTP 100 m (328 ft)
D-coding connector
8-pin female M12
1000BASE-T
Cat. 5/Cat. 5e 100-ohm UTP UTP 100 m (328 ft)
X-coding connector
For pin assignments of the M12 ports, please refer to the following tables.
4-Pin PoE Fast Ethernet Port Definition
1
2
10/100Base-T(X) P.S.E M12 port with D-Coding
Tx+
Rx+
Pin No.
Description
#1
Tx+ with PoE Vout+
#2
Rx+ with PoE Vout-
Rx-
Tx-
4
3
#3
Tx- with PoE Vout+
#4
Rx- with PoE Vout-
Quick Installation Guide
Version 1.0
V+
N.C
V-
N.C
RXD
TXD
N.C.
N.C.
GND
RS-232, 115200bps, 8, N, 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TPS-W9124GT-M12X-BP2 -24V-IP54 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ORiNG TPS-W9124GT-M12X-BP2 -24V-IP54

  • Page 1 Installation When installing the device, make sure to keep the radiating at a minimum distance of 20 cm ORing's Transporter series managed PoE Ethernet switches are designed (7.9 inches) from all persons to minimize the potential for human contact during normal...
  • Page 2 For information on operating the device Application-based QoS management FAX: +886-2-2218-1014 E-mail: support@oringnet.com DOS/DDOS auto prevention using ORing’s Open-Vision management utility, please go to ORing website. Port configuration, status, statistics, monitoring, security DHCP Server/Client/Relay SMTP Client Modbus TCP...

Table of Contents