Page 2
ORing warrants that all ORing products are free from defects in material and workmanship for a specified warranty period from the invoice date (5 years for most products). ORing will repair or replace products found by ORing to be defective within this warranty period, with shipment expenses apportioned by ORing and the distributor.
IP-based bandwidth management which can limit the maximum bandwidth for each IP device. The user can configure IP camera and NVR with more bandwidth and limit other device bandwidth. ORing’s Thunder switch series also support application-based QoS. Application-based QoS can set highest priority for data stream according to TCP/UDP port number.
Operating Humidity: 5% to 95%, non-condensing Casing: IP-30 16 x Combo ports with 10/100/1000Base-T(X) and 100/1000 Base-X SFP 8 x 100/1000Base-X SFP ports Console Port Dimensions : 431 (W) x 342 (D) x 44 (H) mm ORing Industrial Networking Corp.
.LED for R.M. (Ring master): When the LED lights on, this switch is designated as the ring master of the Ring topology. .LED for Ring: When the led light on, the O-Ring is activated. .LED for DEF: System resets to default configuration. ORing Industrial Networking Corp.
Page 9
.LED for DEF: System resets to default configuration. .LED for Ping: System is processing “PING” request. .LED for RUN: System is operating continuously. .LED for RMT: System is accessed remotely. .LED for Fault: Indicates unexpected event occurred. ORing Industrial Networking Corp.
2.3 Rack-Mount Kit Assembly You can find the rack-mount kit and the screws in the packing box. Please assemble the rack- mount kit on the switch with screws as shown below: 2.4 Front Panel LEDs Color Status Description ORing Industrial Networking Corp.
Page 11
10/100/1000Base-T(X) Gigabit Ethernet ports Port speed 1000M link up Green Blinking Data Transmitted on 1000M LINK/ACT Port speed 10/100M link up Amber Blinking Data Transmitted on 10/100M Port link up. LINK/ACT Green Blinking Data transmitted ORing Industrial Networking Corp.
3 and 6 are used for receiving data. 10/100 Base-T RJ-45 Pin Assignments Pin Number Assignment Not used Not used Not used Not used 1000 Base-T RJ-45 Pin Assignments Pin Number Assignment BI_DA+ BI_DA- BI_DB+ BI_DC+ ORing Industrial Networking Corp.
Page 13
MDI port MDI-X port BI_DA+ BI_DB+ BI_DA- BI_DB- BI_DB+ BI_DA+ BI_DC+ BI_DD+ BI_DC- BI_DD- BI_DB- BI_DA- BI_DD+ BI_DC+ BI_DD- BI_DC- Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair. ORing Industrial Networking Corp.
Note: By default, IE5.0 or later version does not allow Java Applets to open sockets. You need to explicitly modify the browser setting in order to enable Java Applets to use network ports. ORing Industrial Networking Corp.
Page 16
Type http:// and the IP address of the switch. Press “Enter”. The login screen appears. Key in the username and password. The default username and password is “admin”. Click “Enter” or “OK” button. Then the main interface of the Web-based management appears. Login screen ORing Industrial Networking Corp.
(0-9), and the minus sign (-). No space characters are permitted as part of a name. The first character must be an alphabet, and the first or last character must not be a minus sign. System The administratively assigned description for this managed ORing Industrial Networking Corp.
New Password The system password. The allowed string length is 0 to 31, and the allowed contents are the ASCII characters from 32 to 126. Confirm password Re-type the new password. Click to save changes. ORing Industrial Networking Corp.
SNTP is an acronym for Simple Network Time Protocol, a network protocol for synchronizing the clocks of computer systems. SNTP uses UDP (datagrams) as transport layer. Click to save changes. Click to undo any changes made locally and revert to previously saved values. ORing Industrial Networking Corp.
Click to undo any changes made locally and revert to previously saved values. 4.1.2.5 SSH Label Description Indicates the SSH mode operation. Possible modes are: Mode Enabled: Enable SSH mode operation. Disabled: Disable SSH mode operation. Click to save changes. ORing Industrial Networking Corp.
Mode LLDP Neighbor Information This page provides a status overview for all LLDP neighbors. The displayed table contains a row for each port on which an LLDP neighbor is detected. The columns hold the following information: ORing Industrial Networking Corp.
Page 22
This page provides an overview of all LLDP traffic. Two types of counters are shown. Global counters are counters that refer to the whole stack, switch, while local counters refer to counters for the currently selected switch. ORing Industrial Networking Corp.
Page 23
Chassis ID or Remote Port ID is not already contained within the table. Entries are removed from the table when a given port links down, an LLDP shutdown frame is received, or when the entry ages out. ORing Industrial Networking Corp.
Page 24
Age-Out counter is incremented. Click to refresh the page immediately. Clears the local counters. All counters (including global counters) are cleared upon reboot. Check this box to enable an automatic refresh of the page at regular intervals. ORing Industrial Networking Corp.
This page facilitates an update of the firmware controlling the stack. switch. 4.1.3 DHCP Server 4.1.3.1 Setting The system provides with DHCP server function. Enable the DHCP server function, the switch system will be a DHCP server. ORing Industrial Networking Corp.
When the device is connecting to the port and asks for dynamic IP assigning, the system will assign the IP address that has been assigned before in the connected device. 4.1.4 Port Setting 4.1.4.1 Port Control This page displays current port configurations. Ports can also be configured here. ORing Industrial Networking Corp.
Page 27
Total power usage in board, measured in percent. Click to save changes. Click to undo any changes made locally and revert to previously saved values. Click to refresh the page. Any changes made locally will be undone. ORing Industrial Networking Corp.
Configure the unit of measure for the port shaper rate as kbps or Shaper Unit Mbps. The default value is "kbps". Click to save changes. Click to undo any changes made locally and revert to previously saved values. ORing Industrial Networking Corp.
The TCP/UDP port number can be used to calculate the destination port for the frame. Check to enable the use of the Number TCP/UDP Port Number, or uncheck to disable. By default, TCP/UDP Port Number is enabled. ORing Industrial Networking Corp.
Page 30
By default, no ports belong to any aggregation group. Only full duplex ports can join an aggregation and ports must be in the same speed in each group. ORing Industrial Networking Corp.
Page 31
LACP packets each second, while Passive will wait for a LACP packet from a partner (speak if spoken to). Click to save changes. Click to undo any changes made locally and revert to previously saved values. ORing Industrial Networking Corp.
Page 32
Shows which ports are a part of this aggregation for this Last Channged switch/stack. The format is: "Switch ID:Port". Click to refresh the page immediately. Check this box to enable an automatic refresh of the page at regular intervals. ORing Industrial Networking Corp.
Page 33
The partners System ID (MAC address). Partner Port The partners port number connected to this port. Click to refresh the page immediately. Check this box to enable an automatic refresh of the page at regular intervals. ORing Industrial Networking Corp.
Page 34
Shows how many unknown or illegal LACP frames have been discarded at each port. Click to refresh the page immediately. Check this box to enable an automatic refresh of the page at regular intervals. Clears the counters for all ports ORing Industrial Networking Corp.
The following table describes the labels in this screen. Label Description Mark to enable O-Ring. O-Ring There should be one and only one Ring Master in a ring. Ring Master However if there are two or more switches that are set as Ring ORing Industrial Networking Corp.
The STP protocol version setting. Valid values are STP, RSTP Protocol Version and MSTP. The delay used by STP Bridges to transition Root and Designated Forward Delay Ports to Forwarding (used in STP compatible mode). Valid values ORing Industrial Networking Corp.
Page 37
Click to undo any changes made locally and revert to previously saved values. MSTI Mapping This page allows the user to inspect the current STP MSTI bridge instance priority configurations, and possibly change them as well. ORing Industrial Networking Corp.
Page 38
Click to undo any changes made locally and revert to previously saved values. MSTI Priorities This page allows the user to inspect the current STP MSTI bridge instance priority configurations, and possibly change them as well. ORing Industrial Networking Corp.
Page 39
Controls the path cost incurred by the port. The Auto setting will set the path cost as appropriate by the physical link speed, using Path Cost the IEEE 802.1D recommended values. Using the Specific setting, a user-defined value can be entered. The path cost is ORing Industrial Networking Corp.
Page 40
Controls whether the port connects to a point-to-point LAN rather than a shared medium. This can be automatically determined, or Point2Point forced either true or false. Transition to the forwarding state is faster for point-to-point LANs than for shared media. ORing Industrial Networking Corp.
Page 41
MSTI instance must be selected before displaying actual MSTI port configuration options. This page contains MSTI port settings for physical and aggregated ports. The aggregation settings are stack global. Label Description The switch port number of the corresponding STP CIST (and Port MSTI) port. ORing Industrial Networking Corp.
Page 42
Bridges, it is the sum of the Port Path Costs on the least cost path Root Cost to the Root Bridge. The current state of the Topology Change Flag for this Bridge Topology Flag instance. Topology Change The time since last Topology Change occurred. Last ORing Industrial Networking Corp.
Page 43
Blocking Learning Forwarding. Uptime The time since the bridge port was last initialized. Click to refresh the page immediately. Check this box to enable an automatic refresh of the page at regular intervals. ORing Industrial Networking Corp.
Page 44
The number of illegal Spanning Tree BPDU's received (and Discarded Illegal discarded) on the port. Click to refresh the page immediately. Check this box to enable an automatic refresh of the page at regular intervals. ORing Industrial Networking Corp.
Entry switch units, but with no port members. A VLAN without any port members on any stack unit will be deleted when you click "Save". button can be used to undo the addition of new VLANs. ORing Industrial Networking Corp.
Page 47
RGS-7168GCP(-E) User’s Manual (For egress port) 1. VLAN Membership Configuration setting port 2 & VID=50 2. VLAN Port 2 Configuration-->don't care VLAN Aware 3. VLAN Port 2 Configuration-->Mode=specific,ID=50 (any packet can enter egress port) ORing Industrial Networking Corp.
Page 48
IEEE 802.1Q Access port Setting (For ingress port) 1. VLAN Membership Configuration setting port & VID=50 2. VLAN Port Configuration-->Enable VLAN Aware 1. VLAN Port Configuration-->Mode=specific,ID=50 (For egress port) 1. VLAN Membership Configuration setting port & VID=50 ORing Industrial Networking Corp.
Page 49
2. VLAN Port Configuration-->Disable VLAN Aware 3. VLAN Port Configuration-->Mode=specific,ID=50 (untagged & tag=50 packet can enter egress port ) IEEE 802.1Q Trunk port setting (multi-tag) RGS-7168GCP(-E) RGS-7168GCP(-E) (For ingress port) 1. VLAN Membership Configuration setting port & VID=11,22,33 ORing Industrial Networking Corp.
Page 50
3. VLAN Port Configuration-->Mode=specific,ID=11 (when enterring packet is untagged frame, added tag = 11 When entering the tagged frame, only VID = 11,22,33 three kinds of packets can pass) (For egress port) 1. VLAN Membership Configuration setting port, VID=11,22,33 ORing Industrial Networking Corp.
Page 51
RGS-7168GCP(-E) User’s Manual 2. VLAN Port Configuration-->Enable VLAN Aware 3. VLAN Port Configuration-->Mode=none (egress port can receive tag=11,22,33 packet In addition ,only tag=11packet can enter egress port ) ORing Industrial Networking Corp.
Page 52
RGS-7168GCP(-E) User’s Manual QinQ VLAN Setting ingress Port 1------------------->egress Port 2 (For ingress port-----Port 1) 1. VLAN Membership Configuration setting port 1、2、3 & VID=50 2. VLAN Port Configuration-->Disable Port 1 VLAN Aware ORing Industrial Networking Corp.
Page 53
3. VLAN Port Configuration-->Port 1 Mode=specific,ID=50 (For egress port ----Port 2) 1. VLAN Membership Configuration setting port & VID=50 2. VLAN Port Configuration-->Enable Port 2、3 VLAN Aware. 3. VLAN Port Configuration-->Mode=none (only tag=50 packet can enter egress port ) ORing Industrial Networking Corp.
Click "OK" to discard the incorrect entry, or click "Cancel" to return to the editing and make a correction. The Private VLAN is enabled when you click "Save". button can be used to undo the addition of new Private VLANs. ORing Industrial Networking Corp.
ASCII characters from 33 to 126. Read Community The field only suits to SNMPv1 and SNMPv2c. SNMPv3 is using USM for authentication and privacy and the community string will associated with SNMPv3 communities table. ORing Industrial Networking Corp.
Page 56
Provide the trap destination IPv6 address of this switch. IPv6 address Trap Destination is a 128-bit record represented as eight fields of up to four IPv6 Address hexadecimal digits with a colon separating each field (:). For ORing Industrial Networking Corp.
Page 57
Indicates the SNMP trap security name. SNMPv3 traps and informs Trap Security using USM for authentication and privacy. A unique security name is Name needed when traps and informs are enabled. ORing Industrial Networking Corp.
SNMPv3 architecture uses the User-based Security Model (USM) for Engine ID message security and the View-based Access Control Model (VACM) for access control. For the USM entry, the usmUserEngineID and usmUserName entry's keys. simple agent, usmUserEngineID is always that agent's own snmpEngineID value. ORing Industrial Networking Corp.
Page 59
DES: An optional flag to indicate that this user using DES authentication protocol. A string identifying the privacy pass phrase. The allowed string length Privacy Password is 8 to 32, and the allowed content is the ASCII characters from 33 to 126. ORing Industrial Networking Corp.
The allowed string length is 1 to 32, and the allowed content is the Group Name ASCII characters from 33 to 126. 4.1.7.5 SNMP-Views Configure SNMPv3 views table on this page. The entry index keys are View Name and OID Subtree. ORing Industrial Networking Corp.
ASCII characters from 33 to 126. Indicates the security model that this entry should belong to. Possible security models are: Security Model any: Accepted any security model (v1 | v2c | usm). v1: Reserved for SNMPv1. ORing Industrial Networking Corp.
Page 62
The name of the MIB view defining the MIB objects for which this request may potentially SET new values. The allowed string length is Write View Name 1 to 32, and the allowed content is the ASCII characters from 33 to 126. ORing Industrial Networking Corp.
Select the default tag priority for this port when adding a Tag to Tag Priority the untagged frames. Queuing Mode Select which Queuing mode for this port. Setting Queue weighted (Low=Normal, Medium=High) if the Queue Weighted "Queuing Mode" is "Weighted". ORing Industrial Networking Corp.
ToS: The 3 precedence bit in the ToS byte of the IPv4/IPv6 header (also known as DS field). Tag Priority: User Priority. Only applicable if the frame is VLAN tagged or priority tagged. Indicates the value according to its QCE type. Type Value ORing Industrial Networking Corp.
VLAN is configured on the IP setup page.) Label Description The settings in a particular row apply to the frame type listed here: Frame Type unicast, multicast, or broadcast. Status Enable or disable the storm control status for the given frame type. ORing Industrial Networking Corp.
Set up the traffic class mapping to the precedence part of ToS (3 bits) Precedence when receiving IPv4/IPv6 packets. Mapping Set up the traffic class mapping to the User Priority value (3 bits) Set up VLAN Tag Priority Mapping when receiving VLAN tagged packets. ORing Industrial Networking Corp.
Ethernet switch that leads towards the Layer 3 multicast device or Router Port IGMP querier. If an aggregation member port is selected as a router port, the whole aggregation will act as a router port. Fast Leave Enable the fast leave on the port. ORing Industrial Networking Corp.
The number of Received V3 Reports. Receive V2 Leave Receive The number of Received V2 Leave. Click to refresh the page immediately. Clears all Statistics counters. Check this box to enable an automatic refresh of the page at regular intervals. ORing Industrial Networking Corp.
Shutdown Enabled: If a frame is received on the port, the port will be disabled. Disabled: Port shut down is disabled. The default value is "Disabled". Counts the number of frames that match this ACE. Counter ORing Industrial Networking Corp.
This is only possible if the Authentication Method is set to something else than 'none or 'local'. Click to save changes. Click to undo any changes made locally and revert to previously saved values. Common Server Configuration ORing Industrial Networking Corp.
Page 71
This will stop the switch from continually trying to contact a server that it has already determined as dead. Setting the Dead Time to a value greater than 0 (zero) will enable this feature, but only if more than one server has been configured. ORing Industrial Networking Corp.
RADIUS Accounting Server and the switchstack. 4.1.11 Warning (for RGS-7168GCP-E) 4.1.11.1 Fault Alarm When any selected fault event is happened, the Fault LED in switch panel will light up and the electric relay will signal at the same time. ORing Industrial Networking Corp.
RFC 3164 - The BSD SYSLOG Protocol The following table describes the labels in this screen. Label Description The remote SYSLOG Server IP address. IP Address Click “Apply” to set the configurations. Apply Show help file. Help ORing Industrial Networking Corp.
If the learning mode for a given port is grayed out, another module is in control of the mode, so that it cannot be changed by the user. An example of such a module is the MAC-Based Authentication under IEEE 802.1X. Each port can do learning based upon the following settings: ORing Industrial Networking Corp.
All frames transmitted on a given port (also known as egress or destination mirroring). Port to mirror is also known as the mirror port. Frames from ports that have either source (rx) or destination (tx) mirroring enabled are mirrored to this port. Disabled disables mirroring. ORing Industrial Networking Corp.
Tx frames for the mirror port. Because of this, mode for the selected mirror port is limited to Disabled or Rx only. 4.1.12.3 System Log Information The switch system log information is provided here. ORing Industrial Networking Corp.
Updates the system log entries, starting from the last entry currently displayed. Updates the system log entries, ending at the last available entry ID. 4.1.12.4 Detailed Log The switch system detailed log information is provided here. ORing Industrial Networking Corp.
Page 78
Updates the system log entries, ending at the last entry currently displayed. Updates the system log entries, starting from the last entry currently displayed. Updates the system log entries, ending at the last available entry ID. ORing Industrial Networking Corp.
This page provides detailed traffic statistics for a specific switch port. Use the port select box to select which switch port details to display. The displayed counters are the totals for receive and transmit, the size counters for receive and transmit, and the error counters for receive and transmit. ORing Industrial Networking Corp.
Page 80
Rx Fragments The number of short 1 frames received with invalid CRC. Rx Jabber The number of long 2 frames received with invalid CRC. Rx Filtered The number of received frames filtered by the forwarding process. ORing Industrial Networking Corp.
You can configure the following properties of the issued ICMP packets: Label Description IP Address The destination IP Address. Ping Size The payload size of the ICMP packet. Values range from 8 bytes to 1400 bytes. ORing Industrial Networking Corp.
10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete. Label Description Port The port where you are requesting VeriPHY Cable Diagnostics. Cable Status Port: Port number. Pair: The status of the cable pair. Length: The length (in meters) of the cable pair. ORing Industrial Networking Corp.
You can reset the stack switch on this page. After reset, the system will boot normally as if you had powered-on the devices Label Description Click to reboot device. Click to return to the Port State page without rebooting. ORing Industrial Networking Corp.
Console port to your PC’s COM port. Follow the steps below to access the console via RS-232 serial cable. Step 1 From the Windows desktop, click on Start -> Programs -> Accessories -> Communications -> Hyper Terminal ORing Industrial Networking Corp.
Page 85
RGS-7168GCP(-E) User’s Manual Step 2 Input a name for new connection Step 3 Select to use COM port number ORing Industrial Networking Corp.
Page 86
Step 4 The Console login screen will appear. Use the keyboard to enter the Username and Password (The same with the password for Web Browser), then press “Enter”. CLI Management by Telnet Users can use “TELNET” to configure the switches. The default values are shown as the following: IP Address: 192.168.10.1 ORing Industrial Networking Corp.
Page 87
Telnet to the IP address of the switch from the Windows “Run“ command (or from the MS-DOS prompt) as below. Step 2 The Login screen will appear. Use the keyboard to enter the Username and Password (The same with the password for Web Browser ), and then press “Enter” ORing Industrial Networking Corp.
Green : Power indicator for AC Green : Power indicator for AC and DC Power-1 Indicator (PW1) Green : Indicate Power-1 input Power-2 Indicator (PW2) Green : Indicate Power-2 input Power-3 Indicator (PW3) Green : Indicate Power-3 input ORing Industrial Networking Corp.
Need help?
Do you have a question about the Thunder Series and is the answer not in the manual?
Questions and answers