Sampling Regime; Output Format - Valeport VA500 Operating Manual

Altimeter
Hide thumbs Also See for VA500:
Table of Contents

Advertisement

Section 4 | Configuration and Operation

4.6 Sampling Regime

# code
Followed By:
S
<CR>
M
rate<CR>
#039
;ModeValue<CR>
#040
<CR>
#028
<CR>

4.7 Output Format

See section 4 for detailed description of output formats
# code
Followed By:
#089
<CR>
;SDDBT<CR>
;TRITEC<CR>
#082
;BENTHOS<CR>
;NMEA<CR>
© 2022 – Valeport Ltd
Operation
Performs Single measurement
Performs continuous measurement at set rate. If rate is
omitted then instrument performs continuous
measurements at previous rate.
1,2, or 4 Hz
Set mode without putting unit into run mode
Where
Mode = M
Value = 1,2 or 4 for Normal mode (M)
Mode = S
for serial trigger single shot measurement
Mode = T
for TTL trigger measurement
Read operating mode.
Puts unit into run mode
Operation
Reads current output format
Sets output format (see
section on output
strings)
Page | 12

Advertisement

Table of Contents
loading