Date: September 2012 This confidential document was prepared by the staff of Valeport Limited, the Company, and is the property of the Company, which also owns the copyright therein. All rights conferred by the law of the copyright and by virtue of international copyright conventions are reserved to the Company.
RS485 is enabled by grounding a pin in the communications lead, See section 6 Digital Output: RS232 & RS485 fitted as standard Protocol: 4800 to 115200 baud, (8,1,N) Formats: Valeport NMEA / Tritech / Kongsberg / $SDDBT NMEA Analogue output: 0-5/10V fitted as standard POWER REQUIREMENTS Input: 9 - 28vDC (isolated power supply) Power: <125 mA @ 12V...
Page 8
6 for analogue outputs) Anaologue range can be 0- 5V or 0-10V Analogue limit distance that equates to full scale voltage output. Serial Data format (see data format section for definition of formats) VA500 Altimeter Manual Page 8 0430831e_VA500_Altimeter_Manual...
Page 9
The next page defines: Output units, seconds, metres, feet or fathoms. Minimum range allows fixed returns close to the VA500 to be filtered out. Maximum range allows filtering of spiking in noisy environments or in the presence multiple echoes. Sound speed is set to 1500m/s.
Page 10
The configuration can also be saved to file for later use or reference. If the Run mode checkbox is ticked the instrument will start outputting data into the terminal window behind once the configuration is complete. VA500 Altimeter Manual Page 10 0430831e_VA500_Altimeter_Manual...
Page 11
MANUALLY CONFIGURING THE UNIT Alternatively the VA500 Altimeter can be manually configured via serial communications using a series of # code commands. This can be with Valeport terminal or an alternative terminal program such as HyperTerminal. Valeport Terminal is preconfigured with the required settings, but for reference the settings...
Page 12
<CR> Puts unit into run mode OUTPUT FORMAT See section 4 for detailed description of output formats #089 <CR> Reads current output format #082 ;SDDBT<CR> Sets output format (see section 4) ;TRITEC<CR> ;BENTHOS<CR> ;NMEA<CR> VA500 Altimeter Manual Page 12 0430831e_VA500_Altimeter_Manual...
OUTPUT FORMATS If the optional pressure sensor is fitted and enabled then the only data format that supports this is the Valeport NMEA format. A number of other formats have been implemented to provide compatibility with existing systems. VALEPORT NMEA $PRVAT, xx.xxx,M, xxxx.xxx, dBar*hh<CR><LF>...
Page 15
The serial output will be in the following format: Rxx.xx<cr><lf> where xx.xx can range from 0.10 to 99.99. If no echo was received the output will be R99.99E<cr><lf>. Example: R00.13 R00.12 R00.12 R00.12 R00.12 R00.12 R00.12 R00.12 VA500 Altimeter Manual Page 15 0430831e_VA500_Altimeter_Manual...