Range Settings - Valeport VA500 Operating Manual

Altimeter
Hide thumbs Also See for VA500:
Table of Contents

Advertisement

Section 4 | Configuration and Operation

4.4 Range Settings

The VA500 has a standard operational range of 0.1m to 100m. If required this can be restricted
with the setting of a minimum range and maximum range.
minimum and maximum ranges are set in metres regardless of the units programmed by setting
The default setting for sound speed used to calculate range is 1500 m/s
# code
Followed By:
#021
;Range_units
#022
<CR>
#118
;0 or 1 or 2<CR>
#119
<CR>
#823
;maximum range<CR>
#824
<CR>
#840
;minimum range<CR>
#841
<CR>
#830
; Value, <CR>
#831
<CR>
© 2022 – Valeport Ltd
#021
Operation
Set to either
0 – Seconds
1 – Metres
2 – Feet
3 – Fathoms
Read range units set above
Set Altimeter Error output message
Where 0=zero (0.000), 1=-999, 2=NR
Reads Altimeter Error output message
set the maximum range that is considered
when processing data (acoustic returns beyond
maximum range are ignored)
Reads maximum range
set the minimum range that is considered when
processing data (acoustic returns before
minimum range are ignored)
Reads minimum range
Variable to change the Speed of Sound ms-1
Reads the sound speed
Page | 10