System - Panasonic AW-RP60GJS Operating Instructions Manual

Remote camera controller
Table of Contents

Advertisement

Menu
(continued)

SYSTEM

⇒ "CAMERA" (page 67)
⇒ "CONNECT SETTING" (page 68)
⇒ "MANUAL IP SET/USER AUTH" (page 69)
⇒ "AUTO IP SET" (page 70)
⇒ "RP IP SET" (page 71)
⇒ "TRACKING" (page 72)
„ CAMERA
CAMERA
POWER
NON
Item
Setting value
CAM POWER
NON
GRP OFF
GRP ON
ALL OFF
ALL ON
AUTO POWER
OFF
ON
CAM LOCK
UNLOCK
LOCK
z "–" is displayed for
z
cameras without
the feature.
AW-UE70
CAM
AUTO
POWER
ON
Execute power On/Off instructions in regard to connected remote cameras.
NON:
Power On/Off instructions not executed.
GRP OFF:
Execute power Off (standby) instructions in regard to remote cameras belonging to the currently
selected camera group.
GRP ON:
Execute power On instructions in regard to remote cameras belonging to the currently selected
camera group.
ALL OFF:
Execute power Off (standby) instructions in regard to remote cameras set in this unit.
ALL ON:
Execute power On instructions in regard to remote cameras set in this unit.
z Depending on the number of remote cameras connected, the unit may take some time before it
can be operated.
The power of remote cameras set in the unit turns on when the power of this unit is turned on.
z Depending on the number of remote cameras connected, the unit may take some time before it
z
can be operated.
This feature is available when connected to a camera that is equipped with the CAM LOCK
function.
When [LOCK] is selected, this unit and currently selected remote cameras cannot be controlled from
another AW‑RP60. While LOCK is on, currently selected remote cameras can only be controlled from
the AW‑RP60 on which LOCK was executed.
Note that if you switch to another remote camera while LOCK is on, the LOCK is maintained on the
remote cameras prior to camera selection, but the remote cameras after camera selection do not
have LOCK applied.
A key mark is displayed next to the camera name at the TOP of the LCD panel while LOCK is on.
When [UNLOCK] is selected, the LOCK is released and the key mark disappears.
Green key mark:
This means that LOCK has been executed on this unit.
Red key mark:
This means that another AW‑RP60 has been used for LOCK. Operation is not possible in this case.
CAM
LOCK
Setting details
67
___ indicates factory default settings.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aw-rp60g

Table of Contents